OSHA Inspection: ANTAYA TECHNOLOGIES CORP.

Referral inspection · Safety discipline

On , OSHA opened a referral safety inspection of ANTAYA TECHNOLOGIES CORP. in 333 STRAWBERRY FIELD ROAD, WARWICK, RI 02886 (NAICS 336320). OSHA activity number 347753170.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Antaya Technologies Corp. — free Get an email when a new federal OSHA severe-injury report for Antaya Technologies Corp. is published. One employer, no account, unsubscribe in one click.
Site address
333 STRAWBERRY FIELD ROAD
City
WARWICK
State
RI
ZIP
02886
Mailing
333 STRAWBERRY FIELD ROAD, WARWICK, RI 02886
Inspection type
Referral (C)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
336320
Employees
437
Ownership type
A

2 citations on file for this inspection.

1910.147 C04 I

Serious Gravity 5 1 instance 1 exposed
Issued
Jan 21, 2025
Penalty
Initial $13,005 · Current $6,503 Reduced
29 CFR  1910.147(c)(4)(i): Procedures were not developed, documented and utilized for the control of potentially hazardous energy when employees were engaged in activities covered by this section.  a) Facility: On or about 8/7/2024, the employer did not ensure that employees utilized lockout/tagout procedures when making service and maintenance adjustments to the piston flow control of the Induction Soldering Cell, serial #RAD-22-074.00.000.
Recent events (2)
  • — I (S) $6502.5
  • — Z (S) $13005

1910.147 C04 II

Serious Gravity 5 1 instance 1 exposed
Issued
Jan 21, 2025
Abate by
Mar 7, 2025
Penalty
Initial $0 · Current $0
29 CFR  1910.147(c)(4)(ii): The energy control procedures did not clearly and specifically outline the scope, purpose, authorization, rules, and techniques to be utilized for the control of hazardous energy, including, but not limited to Items of this section.   a) Facility: On or about 8/7/2024, the employer did not develop and implement energy control procedures that are specific to the Induction Soldering Cell, serial #RAD-22-074.00.000.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

View Antaya Technologies Corp.'s full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 347753170.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.