WARWICK, RI —
OSHA Inspection: ANTAYA TECHNOLOGIES CORP.
Referral inspection · Safety discipline
At a glance
On , OSHA opened a referral safety inspection of ANTAYA TECHNOLOGIES CORP. in 333 STRAWBERRY FIELD ROAD, WARWICK, RI 02886 (NAICS 336320). OSHA activity number 347753170.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- ANTAYA TECHNOLOGIES CORP.
- Site address
- 333 STRAWBERRY FIELD ROAD
- City
- WARWICK
- State
- RI
- ZIP
- 02886
- Mailing
- 333 STRAWBERRY FIELD ROAD, WARWICK, RI 02886
What kind of inspection was it?
- Inspection type
- Referral (C)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 336320
- Employees
- 437
- Ownership type
- A
Citations
2 citations on file for this inspection.
1910.147 C04 I
- Issued
- Jan 21, 2025
- Penalty
- Initial $13,005 · Current $6,503 Reduced
General-duty citation text
29 CFR 1910.147(c)(4)(i): Procedures were not developed, documented and utilized for the control of potentially hazardous energy when employees were engaged in activities covered by this section. a) Facility: On or about 8/7/2024, the employer did not ensure that employees utilized lockout/tagout procedures when making service and maintenance adjustments to the piston flow control of the Induction Soldering Cell, serial #RAD-22-074.00.000.
Recent events (2)
- — I (S) $6502.5
- — Z (S) $13005
1910.147 C04 II
- Issued
- Jan 21, 2025
- Abate by
- Mar 7, 2025
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.147(c)(4)(ii): The energy control procedures did not clearly and specifically outline the scope, purpose, authorization, rules, and techniques to be utilized for the control of hazardous energy, including, but not limited to Items of this section. a) Facility: On or about 8/7/2024, the employer did not develop and implement energy control procedures that are specific to the Induction Soldering Cell, serial #RAD-22-074.00.000.
Recent events (2)
- — I (S) $0
- — Z (S) $0
More inspections at Antaya Technologies Corp.
View Antaya Technologies Corp.'s full OSHA safety record →
More inspections in this industry (NAICS 336320)
More inspections in RI
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 347753170.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.