Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: INLINE PLASTICS CORPORATION

Complaint inspection · Safety discipline

On , OSHA opened a complaint safety inspection of INLINE PLASTICS CORPORATION in 42 CANAL STREET, SHELTON, CT 06484 (NAICS 326199). OSHA activity number 347755605.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Inline Plastics Corporation — free Get an email when a new federal OSHA severe-injury report for Inline Plastics Corporation is published. One employer, no account, unsubscribe in one click.
Site address
42 CANAL STREET
City
SHELTON
State
CT
ZIP
06484
Mailing
42 CANAL STREET, SHELTON, CT 06484
Inspection type
Complaint (B)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
326199
Employees
400
Ownership type
A

2 citations on file for this inspection.

1910.147 D02

Serious Gravity 10 1 instance 1 exposed
Issued
Dec 10, 2024
Penalty
Initial $16,131 · Current $16,131
29 CFR1910.147(d)(2):  An orderly shutdown of machine or equipment was not utilized to avoid any additional or increased hazards to employees as a result of equipment stoppage.  Location: 42 Canal Street Shelton, CT 06484  On or about September 12, 2024, the employer did not require proper/specific energy control procedure shut down and/or alternate protection for an employee clearing a machine jam of the Lyle #7 trim press resulting in the partial amputation of an index finger.
Recent events (1)
  • — Z (S) $16131

1910.147 D03

Serious Gravity 10 1 instance 1 exposed
Issued
Dec 10, 2024
Penalty
Initial $0 · Current $0
29 CFR1910.147(d)(3):  All energy isolating devices that were needed to control the energy to the machine or equipment was not physically located and operated in such a manner as to isolate the machine or equipment from the energy source.   Location: 42 Canal Street Shelton, CT 06484  On or about September 12, 2024, the employer did not ensure the main pneumatic feed valve to the Lyle #7 trim press was operated in such a manner as to isolate machinery components from stored energy, while an employee cleared a jam near ski/roller components in the discharge area.
Recent events (1)
  • — Z (S) $0

View Inline Plastics Corporation's full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 347755605.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.