Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: CTS TECHNICAL RESOURCES, INC.

Referral inspection · Health discipline

On , OSHA opened a referral health inspection of CTS TECHNICAL RESOURCES, INC. in 408 S 2ND STREET, CEDARTOWN, GA 30125 (NAICS 323120). OSHA activity number 347765158.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch CTS Technical Resources, INC. — free Get an email when a new federal OSHA severe-injury report for CTS Technical Resources, INC. is published. One employer, no account, unsubscribe in one click.
Site address
408 S 2ND STREET
City
CEDARTOWN
State
GA
ZIP
30125
Mailing
408 S 2ND STREET, CEDARTOWN, GA 30125
Inspection type
Referral (C)
Scope
Partial (B)
Discipline
Health
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
323120
Employees
14
Ownership type
A

2 citations on file for this inspection.

1910.1200 E01

Serious Gravity 5 1 instance 1 exposed
Issued
Feb 19, 2025
Abate by
Mar 19, 2025
Penalty
Initial $3,783 · Current $1,892 Reduced
29 CFR  1910.1200(e)(1):The employer did not develop, implement, and/or maintain at the workplace a written hazard communication program which describes how the criteria specified in 29 CFR 1910.1200(f), (g), and (h) will be met:  a) Plasma Department; On or about September 11, 2024, and at times prior, the employer exposed employees to chemical hazards, in that the employer did not implement a written hazard communication program on hazardous chemicals, such as but not limited to, employee information and hazard communication training.
Recent events (2)
  • — I (S) $1891.5
  • — Z (S) $3783

1910.134 C02 II

Other-than-serious 1 instance 1 exposed
Issued
Feb 19, 2025
Abate by
Mar 19, 2025
Penalty
Initial $0 · Current $0
29 CFR  1910.134(c)(2)(ii): The employer did not establish and implement those elements of a written program necessary to ensure that any employee using a respirator voluntarily was medically able to use that respirator, and that the respirator was cleaned, stored, and maintained so that its use does not present a health hazard to the user:  a) Plasma Department: On or about September 11, 2024, and at times prior, the employer exposed employees to respiratory hazards, in that a written respiratory protection program was not developed and implemented for employees that were tasked with disposing filters/barrels containing debris, such as but limited to, Chromium Oxide and voluntarily use half face elastomeric respirators.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

View CTS Technical Resources, INC.'s full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 347765158.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.