Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: ADLER PELZER GROUP

Complaint inspection · Safety discipline

On , OSHA opened a complaint safety inspection of ADLER PELZER GROUP in 1150 N WYNN RD, OREGON, OH 43616 (NAICS 336360). OSHA activity number 347788325.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Adler Pelzer Group — free Get an email when a new federal OSHA severe-injury report for Adler Pelzer Group is published. One employer, no account, unsubscribe in one click.
Establishment
ADLER PELZER GROUP
Site address
1150 N WYNN RD
City
OREGON
State
OH
ZIP
43616
Mailing
1150 N WYNN RD, OREGON, OH 43616
Inspection type
Complaint (B)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
336360
Employees
150
Ownership type
A

6 citations on file for this inspection.

1910.28 B03 II

Other-than-serious Gravity 5 1 instance 4 exposed
Issued
Feb 4, 2025
Penalty
Initial $14,187 · Current $0 Reduced
29 CFR 1910.28(b)(3)(ii): The employer did not ensure that each employee be protected from tripping into or stepping into or through any hole that is less than 4 feet (1.2 m) above a lower level by covers or guardrail systems.  a) Adler Pelzer Group on or about October 15, 2024, at the location of 1550 N. Wynn Rd. Oregon, Ohio 43616: The employer did not ensure open floor holes were effectively guarded or covered on the Manual Line. Due to this condition, employees operating the Manual Bruno press in proximity of these holes were exposed to a tripping/falling hazards.
Recent events (2)
  • — I (O) $0
  • — Z (S) $14187

1910.147 C07 I

Serious Gravity 10 1 instance 4 exposed
Issued
Feb 4, 2025
Penalty
Initial $16,550 · Current $8,275 Reduced
29 CFR  1910.147(c)(7)(i): The employer did not provide adequate training to ensure that employees acquired the knowledge and skills required for the safe application, usage and removal of energy control devices.  a) Adler Pelzer Group on or about October 1, 2024 at the location of 1550 N. Wynn Rd. Oregon, Ohio 43616: The employer did not effectively train employees to ensure that the purpose and function of the energy control program was understood by employees. Due to this condition employees tasked with cleaning heat tables one and two of the Turbo (Rat) Line were exposed to crushing hazards when performing service and maintenance tasks.
Recent events (2)
  • — I (S) $8275
  • — Z (S) $16550

1910.212 A01

Serious Gravity 5 1 instance 2 exposed
Issued
Feb 4, 2025
Abate by
Feb 13, 2025
Penalty
Initial $9,457 · Current $4,729 Reduced
29 CFR  1910.212(a)(1): One or more methods of machine guarding was not provided to protect the operator and other employees in the machine area from hazards such as those created by point of operation, ingoing nip points, rotating parts, flying chips and sparks.  a) Adler Pelzer Group on or about October 15, 2024 at the location of 1550 N. Wynn Rd. Oregon, Ohio 43616: The employer did not ensure employees were adequately protected from pinch points, caught in hazards, and crushing hazards created by the air actuated clamps of the "Wheel Arch Liner" mold on the Manual line.  Due to this condition, employees tasked with operating the air actuated clamps were exposed to abovementioned hazards.
Recent events (2)
  • — I (S) $4729
  • — Z (S) $9457

1910.303 B07 I

Serious Gravity 5 1 instance 4 exposed
Issued
Feb 4, 2025
Abate by
Feb 13, 2025
Penalty
Initial $9,457 · Current $4,729 Reduced
29 CFR  1910.303(b)(7)(i):Unused openings in boxes, raceways, auxiliary gutters, cabinets, equipment cases, or housings were not effectively closed to afford protection substantially equivalent to the wall of the equipment:  a) Adler Pelzer Group on or about October 15, 2024 at the location of 1550 N. Wynn Rd. Oregon, Ohio 43616: The employer did not ensure unused openings on the Dule Gantry Bruno Press control cabinet (480v) were effectively closed.  Due to this condition, employee tasked with operating the machine in proximity of live conductors were exposed to electrical shock hazards.
Recent events (2)
  • — I (S) $4729
  • — Z (S) $9457

1910.332 B01

Serious Gravity 10 1 instance 5 exposed
Issued
Feb 4, 2025
Abate by
Sep 15, 2025
Penalty
Initial $16,550 · Current $8,275 Reduced
29 CFR  1910.332(b)(1):Employees were not trained in and familiar with the safety-related work practices required by 1910.331 through 1910.335 that pertained to their respective job assignments.  a) Adler Pelzer Group on or about October 15, 2024 at the location of 1550 N. Wynn Rd. Oregon, Ohio 43616: The employer did not ensure employees tasked with installing and maintaining electrical equipment, where potentially live conductors were present were familiar with safety related work practices. Due to this condition employees relocating and installing electrical equipment for the Manual Line Contact Ovens were exposed to electrical shock and arch flash hazards.
Recent events (3)
  • — P (S) $8275
  • — I (S) $8275
  • — Z (S) $16550

1910.335 A01 I

Serious Gravity 10 1 instance 5 exposed
Issued
Feb 4, 2025
Abate by
Jun 13, 2025
Penalty
Initial $16,550 · Current $8,275 Reduced
29 CFR  1910.335(a)(1)(i):Employees working in areas where there were potential electrical hazards were not provided with electrical protective equipment that was appropriate for the specific parts of the body that needed to be protected and for the work being performed.  a) Adler Pelzer Group on or about October 15, 2024, at the location of 1550 N. Wynn Rd. Oregon, Ohio 43616: The employer did ensure employee performing electrical work on 110v, 220v and  480v systems, were provided with and used appropriate electrical protective equipment for the body, hands, head, and face. Due to this condition employees tasked with installing and maintaining electrical equipment where potential live conductors were present, were exposed to electrical shock and arc flash hazards.
Recent events (2)
  • — I (S) $8275
  • — Z (S) $16550

View Adler Pelzer Group's full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 347788325.