Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: COMPCO INDUSTRIES INC.

Complaint inspection · Safety discipline

On , OSHA opened a complaint safety inspection of COMPCO INDUSTRIES INC. in 400 W. RAILROAD ST., SUITE 2, COLUMBIANA, OH 44408 (NAICS 332420). OSHA activity number 347791329.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Compco Industries INC. — free Get an email when a new federal OSHA severe-injury report for Compco Industries INC. is published. One employer, no account, unsubscribe in one click.
Site address
400 W. RAILROAD ST., SUITE 2
City
COLUMBIANA
State
OH
ZIP
44408
Mailing
400 W. RAILROAD ST., SUITE 2, COLUMBIANA, OH 44408
Inspection type
Complaint (B)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
332420
Employees
174
Ownership type
A

5 citations on file for this inspection.

1910.147 C04 I

Serious Gravity 10 1 instance 5 exposed
Issued
Nov 14, 2024
Abate by
Dec 19, 2024
Penalty
Initial $15,970 · Current $11,179 Reduced
29 CFR  1910.147(c)(4)(i): Procedures were not developed, documented and utilized for the control of potentially hazardous energy when employees were engaged in activities covered by this section.   On or about  October 2, 2024, the employer failed to ensure that procedures were developed, documented, and utilized for Robotic Press #32 (Taylor Winfield Technologies, Brilex Technical Solutions).  Employees are performing tasks, such as but not limited to, clearing and resetting system faults on Press #32 without applying lock out tag out.
Recent events (2)
  • — I (S) $11179
  • — Z (S) $15970

1910.147 C07 I A

Serious Gravity 10 1 instance 5 exposed
Issued
Nov 14, 2024
Abate by
Dec 19, 2024
Penalty
Initial $15,970 · Current $0 Reduced
29 CFR  1910.147(c)(7)(i)(A): Authorized employee(s) did not receive training in the recognition of applicable hazardous energy sources, the type and magnitude of the energy available in the workplace, and the methods and means necessary for energy isolation:    On or about October 2, 2024, the employer failed to ensure that employees tasked with clearing faults and resetting the Robotic Press #32 (Taylor Winfield Technologies, Brilex Technical Solutions) were trained as authorized to apply lock out tag out to the press prior to performing this task.
Recent events (2)
  • — I (S) $0
  • — Z (S) $15970

1910.212 A01

Serious Gravity 10 1 instance 5 exposed
Issued
Nov 14, 2024
Penalty
Initial $15,970 · Current $11,179 Reduced
29 CFR  1910.212(a)(1): One or more methods of machine guarding was not provided to protect the operator and other employees in the machine area from hazards such as those created by point of operation, ingoing nip points, rotating parts, flying chips and sparks:   On or about October 2, 2024, the employer failed to ensure that the interlock on the Robotic Press #32 (Taylor Winfield Technologies, Brilex Technical Solutions) was working. The press was being operated while the rear gate door was open and the interlock on the rear gate is malfunctioning and/or not fully connected for use.
Recent events (2)
  • — I (S) $11179
  • — Z (S) $15970

1910.217 C01 I

Serious Gravity 10 1 instance 5 exposed
Issued
Nov 14, 2024
Penalty
Initial $15,970 · Current $11,179 Reduced
29 CFR  1910.217(c)(1)(i): The employer did not provide and ensure the usage of point of operation guards or properly applied point of operation devices on every operation performed on mechanical power press(es):  On or about September 23, 2024, the employer failed to ensure that the point of operation on Press #1 was adequately guarded. Light curtains that were in place were not functioning properly and at times bypassed, and a two hand pendant control was utilized that was not affixed to the ground and with the press in continuous mode.
Recent events (2)
  • — I (S) $11179
  • — Z (S) $15970

1910.178 P01

Other-than-serious 1 instance 5 exposed
Issued
Nov 14, 2024
Abate by
Dec 4, 2024
Penalty
Initial $0 · Current $0
29 CFR  1910.178(p)(1): Powered industrial truck(s) found to be in need of repair, defective, or in any way unsafe had not been  taken out of service until restored to safe operating condition(s):  On or about October 2, 2024, the employer failed to ensure that the rear sounding alarm was in working order on the #303 powered industrial vehicle.  The alarm does not sound when the vehicle is operating in reverse.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

View Compco Industries INC.'s full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 347791329.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.