On , OSHA opened a planned safety inspection of LIANG CORPORATION in LOT 5359-3-1-R2NEW MANGILAO FOUR (4) UNIT APARTMENT COMPLEX, DEDEDO, GU 96929 (NAICS 236220). OSHA activity number 347827040.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Liang Corporation — free Get an email when a new federal OSHA severe-injury report for Liang Corporation is published. One employer, no account, unsubscribe in one click.
Establishment
LIANG CORPORATION
Site address
LOT 5359-3-1-R2NEW MANGILAO FOUR (4) UNIT APARTMENT COMPLEX
City
DEDEDO
State
GU
ZIP
96929
Mailing
190W MARINE CORP. DR., PMB 568, DEDEDO, GU 96929
Inspection type
Planned (H)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
236220
Employees
13
Ownership type
A

8 citations on file for this inspection.

1926.451 B01

Serious Gravity 5 1 instance 2 exposed
Issued
Feb 14, 2025
Penalty
Initial $3,783 · Current $2,648 Reduced
29 CFR 1926.451(b)(1): Each platform on all working levels of scaffolds was not fully planked or decked between the front uprights and the guardrail supports as specified in paragraphs 1926.451(b)(1)(i)-(ii)  Second level front of building: Employees building the second-floor columns from a scaffolding platform that was not fully planked were exposed to fall hazards.
Recent events (2)
  • — I (S) $2648.1
  • — Z (S) $3783

1926.451 E01

Serious Gravity 5 1 instance 1 exposed
Issued
Feb 14, 2025
Penalty
Initial $0 · Current $0
29 CFR 1926.451(e)(1):When scaffold platforms were more than 2 feet (0.6 m) above or below a point of access, portable ladders, hook-on ladders, attachable ladders, stair towers (scaffold stairways/towers), stairway-type ladders (such as ladder stands), ramps, walkways, integral prefabricated scaffold access, or direct access from other scaffold, structure, personnel hoist, or similar surface was not used. Cross braces were used as a means of access.  Second floor: Employees scaled the scaffolding braces to access the scaffolding platform to work on the second-floor column. Employees were exposed to fall hazards.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1926.451 G04 I

Serious Gravity 5 1 instance 2 exposed
Issued
Feb 14, 2025
Penalty
Initial $0 · Current $0
29 CFR 1926.451(g)(4)(i): Guardrail systems were not installed along all open sides and ends of platforms.  Second level: Guardrails were not installed around the scaffolding platform employees worked on to build the second-floor columns. Employees were exposed to fall hazards.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1926.501 B01

Serious Gravity 5 2 instances 7 exposed
Issued
Feb 14, 2025
Penalty
Initial $4,729 · Current $3,310 Reduced
29 CFR 1926.501(b)(1): Each employee on a walking/working surface with an unprotected side or edge which was 6 feet (1.8 m) or more above a lower level was not protected from falling by the use of guardrail systems, safety net systems, or personal fall arrest systems.  a. Second floor: Employees building the second floor without fall protection were exposed to fall up to 12 feet from the ground  b. Third floor: Employees building the third floor without fall protection were exposed to fall up to 24 feet from the ground.
Recent events (2)
  • — I (S) $3310.3
  • — Z (S) $4729

1926.501 B05

Serious Gravity 5 1 instance 1 exposed
Issued
Feb 14, 2025
Penalty
Initial $0 · Current $0
29 CFR 1926.501(b)(5): Each employee on the face of formwork or reinforcing steel was not protected from falling 6 feet (1.8 m) or more to lower levels by personal fall arrest systems, safety net systems, or positioning device systems:  Second floor: An employee sitting on the column form without fall protection while building the column form was exposed to fall up to 20 feet from the ground.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1926.1052 C01 II

Serious Gravity 1 1 instance 7 exposed
Issued
Feb 14, 2025
Penalty
Initial $2,837 · Current $1,986 Reduced
29 CFR 1926.1052(c)(1)(ii): Stairways having four or more risers or rising more than 30 inches (76 cm), whichever is less, were not equipped with a stairrail system along each unprotected side or edge:  First floor: Stairway used to access the second level was missing stair rail exposing employees to fall hazards.
Recent events (2)
  • — I (S) $1985.9
  • — Z (S) $2837

1926.1053 B13

Serious Gravity 5 1 instance 1 exposed
Issued
Feb 14, 2025
Penalty
Initial $4,729 · Current $3,310 Reduced
29 CFR 1926.1053(b)(13): The top or step of a stepladder was used as a step:  Second floor: An employee building a second-floor column was standing on the top of a step ladder. The employee was exposed to fall hazards.
Recent events (2)
  • — I (S) $3310.3
  • — Z (S) $4729

1926.416 E01

Other-than-serious 1 instance 2 exposed
Issued
Feb 14, 2025
Penalty
Initial $0 · Current $0
29 CFR 1926.416(e)(1): Worn or frayed electric cords or cables were used:  In front of the building: A damaged extension cord was used to power the rebar cutter exposing employees to electrical hazards.