MONGMONG, GU —
OSHA Inspection: QCB INCORPORATED
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of QCB INCORPORATED in BIANG STREET, MONGMONG, GU 96910 (NAICS 238160). OSHA activity number 347842627.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- QCB INCORPORATED
- Site address
- BIANG STREET
- City
- MONGMONG
- State
- GU
- ZIP
- 96910
- Mailing
- P.O. BOX 26560, BARRIGADA, GU 96913
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Complete (A)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Last modified
- Data loaded
Establishment context
- NAICS code
- 238160
- Employees
- 3
- Ownership type
- A
Citations
4 citations on file for this inspection.
1926.501 B13
- Issued
- Dec 4, 2024
- Penalty
- Initial $2,765 · Current $2,765
General-duty citation text
29 CFR 1926.501(b)(13): Each employee(s) engaged in residential construction activities 6 feet (1.8 m) or more above lower levels were not protected by guardrail systems, safety net system, or personal fall arrest system, nor were employee(s) provided with an alternative fall protection measure under another provision of paragraph 1926.501 (b): Left side of the roof: An employee was working on a roof not protected by a guard rail, safety net, or personal fall arrest system. Employees were exposed to fall hazards.
Recent events (1)
- — Z (S) $2765
1926.1053 B01
- Issued
- Dec 4, 2024
- Penalty
- Initial $2,765 · Current $2,765
General-duty citation text
29 CFR 1926.1053(b)(1): Where portable ladders were used for access to an upper landing surface and the ladder's length allows, the ladder side rails did not extend at least 3 feet (.9 m) above the upper landing surface being accessed: Side of the building: The self-supported ladder used to access the roof did not extend at least 3 feet above the landing surface. Employees were exposed to fall hazards.
Recent events (1)
- — Z (S) $2765
1926.1053 B04
- Issued
- Dec 4, 2024
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1926.1053(b)(4): Ladder(s) were used for purposes other than the purpose for which they were designed: Side of the building: An employee used a self-supported ladder in the closed position to access the roof. Employees were exposed to fall hazards.
Recent events (1)
- — Z (S) $0
1926.1053 B13
- Issued
- Dec 4, 2024
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1926.1053(b)(13):The top or top step of a stepladder was used as a step: Side of the building: An employee used the top of a self-supported ladder as a step to access the roof. Employees were exposed to fall hazards
Recent events (1)
- — Z (S) $0
More inspections in this industry (NAICS 238160)
More inspections in GU
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 347842627.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.