DEDEDO, GU —
OSHA Inspection: MEILBERT DE VERA LOPEZ
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of MEILBERT DE VERA LOPEZ in GOODWIND DEVELOPMENT CORPORATION SAN MIGUEL BLDG. ARMY DR., DEDEDO, GU 96929 (NAICS 236220). OSHA activity number 347843252.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- MEILBERT DE VERA LOPEZ
- Site address
- GOODWIND DEVELOPMENT CORPORATION SAN MIGUEL BLDG. ARMY DR.
- City
- DEDEDO
- State
- GU
- ZIP
- 96929
- Mailing
- P.O. BOX 11831, YIGO, GU 96929
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Complete (A)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 236220
- Employees
- 178
- Ownership type
- A
Citations
3 citations on file for this inspection.
1926.405 B02
- Issued
- Feb 19, 2025
- Penalty
- Initial $5,426 · Current $3,798 Reduced
General-duty citation text
29 CFR 1926.405(b)(2): In energized installations, each outlet box did not have a cover, faceplate, or fixture canopy: Near the panel: Outlet boxes supplying power for power tools were not covered exposing employees to electrical and fire hazards.
Recent events (2)
- — I (S) $3798.2
- — Z (S) $5426
1926.403 B02
- Issued
- Feb 19, 2025
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1926.403(b)(2): Listed, labeled or certified equipment was not installed and used in accordance with instructions in the listing, labeling or certification. Fabrication area: A receptacle box designed to be installed in a wall was installed on the end of an extension cord exposing employees to electrical and fire hazards.
Recent events (2)
- — I (O) $0
- — Z (O) $0
1926.405 G02 IV
- Issued
- Feb 19, 2025
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1926.405(g)(2)(iv): Flexible cords were not connected to devices and fittings so that strain relief is provided to prevent pull from being directly transmitted to joints or terminal screws: Fabricating side: The outer insulation to the cord used to power a grinder was pulled from the box exposing the inner wiring. Employees were exposed to electrical and fire hazards.
Recent events (2)
- — I (O) $0
- — Z (O) $0
More inspections at Meilbert DE Vera Lopez
View Meilbert DE Vera Lopez's full OSHA safety record →
More inspections in this industry (NAICS 236220)
More inspections in GU
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 347843252.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.