Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: ACS STEEL CO., LLC

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of ACS STEEL CO., LLC in 7862 S. REGENCY DR., TULSA, OK 74131 (NAICS 332999). OSHA activity number 347850570.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch ACS Steel CO., LLC — free Get an email when a new federal OSHA severe-injury report for ACS Steel CO., LLC is published. One employer, no account, unsubscribe in one click.
Establishment
ACS STEEL CO., LLC
Site address
7862 S. REGENCY DR.
City
TULSA
State
OK
ZIP
74131
Mailing
7862 S. REGENCY DR., TULSA, OK 74131
Inspection type
Planned (H)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
332999
Employees
75
Ownership type
A

12 citations on file for this inspection.

1910.132 D02

Serious Gravity 5 1 instance 1 exposed
Issued
Apr 14, 2025
Abate by
May 1, 2025
Penalty
Initial $9,931 · Current $5,959 Reduced
29 CFR 1910.132(d)(2): The employer did not verify, through a written certification, that the required workplace hazard assessment had been performed.  On or about March 14, 2025, and at times prior to, the employer did not perform written certification of a hazard assessment of the workplace, identifying hazards and personal protective equipment required throughout the workplace.
Recent events (2)
  • — I (S) $5958.6
  • — Z (S) $9931

1910.133 A01

Serious Gravity 5 1 instance 1 exposed
Issued
Apr 14, 2025
Abate by
May 1, 2025
Penalty
Initial $0 · Current $0
29 CFR 1910.133(a)(1): The employer did not ensure that each affected employee uses appropriate eye or face protection when exposed to eye or face hazards from flying particles, molten metal, liquid chemicals, acids or caustic liquids, chemical gases or vapors, or potentially injurious light radiation.  On or about March 14, 2025, and at times prior to, within the welding shop, effective eye and face protection was not worn by employees when performing welding and grinding operations.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.179 L03 III D

Serious Gravity 1 1 instance 1 exposed
Issued
Apr 14, 2025
Abate by
May 1, 2025
Penalty
Initial $4,965 · Current $2,979 Reduced
29 CFR 1910.179(l)(3)(iii)(d): Pendant control stations were not kept clean, and/or their function labels were not kept legible.  On or about October 29, 2024, and at times prior to, inside the roll production line of the facility, employee(s) utilized an overhead crane with a pendant not being clean and labels were not legible and were missing, while employees lift heavy equipment and parts.
Recent events (2)
  • — I (S) $2979
  • — Z (S) $4965

1910.252 B02 III

Serious Gravity 1 1 instance 1 exposed
Issued
Apr 14, 2025
Abate by
May 1, 2025
Penalty
Initial $4,965 · Current $2,979 Reduced
29 CFR 1910.252(b)(2)(iii): Workers and other persons adjacent to the welding area were not protected from the rays by noncombustible or flameproof screens or shields.  On or about October 29, 2024, and at times prior to, within the metal roll production area, employee(s) were not provided with sufficient welding screens to protect other workers and visitors while performing welding operations within the metal roll production area.
Recent events (2)
  • — I (S) $2979
  • — Z (S) $4965

1910.253 B02 IV

Serious Gravity 5 1 instance 1 exposed
Issued
Apr 14, 2025
Abate by
May 1, 2025
Penalty
Initial $0 · Current $0
29 CFR 1910.253(b)(2)(iv): Valve protection caps, where cylinders were designed to accept caps, were not always in place, hand-tight, except when cylinders were in use or connected for use.  On or about October 29, 2024, and at times prior to, outside on the east side of the building near the parking lot, employee(s) accessed compressed gas cylinders in storage without valve protection caps installed.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.253 B04 III

Serious Gravity 5 1 instance 1 exposed
Issued
Apr 14, 2025
Abate by
May 1, 2025
Penalty
Initial $0 · Current $0
29 CFR 1910.253(b)(4)(iii): Oxygen cylinders in storage were not separated from fuel-gas cylinders or combustible materials (especially oil or grease), a minimum distance of 20 feet (6.1 m) or by a noncombustible barrier at least 5 feet (1.5 m) high having a fire-resistance rating of at least one-half hour.  On or about October 29, 2024, and at times prior to, outside on the east wall of the facility near the parking lot and street, oxygen compressed gas cylinders were stored less than 20 feet from liquified petroleum gas (LPG) cylinders and hydrogen mixed gas cylinders.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.303 F02

Serious Gravity 5 1 instance 1 exposed
Issued
Apr 14, 2025
Abate by
May 1, 2025
Penalty
Initial $6,620 · Current $3,972 Reduced
29 CFR 1910.303(f)(2): Each service, feeder, and branch circuit, at its disconnecting means or overcurrent device, was not legibly marked to indicate its purpose, nor located and arranged so the purpose was evident.  On or about October 29, 2024, and at times prior to, near the isle on the east wall of the roll production area, a circuit breaker panel did not have proper markings to identify breakers powering the outlets and other items within the middle metal rolling bay.
Recent events (2)
  • — I (S) $3972
  • — Z (S) $6620

1910.305 B01 II

Serious Gravity 5 1 instance 1 exposed
Issued
Apr 14, 2025
Abate by
May 1, 2025
Penalty
Initial $0 · Current $0
29 CFR 1910.305(b)(1)(ii): Unused openings in boxes, cabinets, or fittings were not effectively closed.  On or about October 29, 2024, and at times prior to, the Webb Corporation Metal Plate Roller power disconnect panel had unused openings, including knockouts not effectively closed.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.305 D02

Serious Gravity 5 1 instance 1 exposed
Issued
Apr 14, 2025
Abate by
May 1, 2025
Penalty
Initial $0 · Current $0
29 CFR 1910.305(d)(2): Panelboard enclosures. Panelboards shall be mounted in cabinets, cutout boxes, or enclosures designed for the purpose and shall be dead front. However, panelboards other than the dead front externally operable type are permitted where accessible only to qualified persons.  On or about October 29, 2024, and at times prior to, on the east wall of the middle bay of the roll production area, employee(s) utilized a circuit breaker panel that did not have a dead front installed.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.305 F01

Serious Gravity 5 1 instance 1 exposed
Issued
Apr 14, 2025
Abate by
May 1, 2025
Penalty
Initial $0 · Current $0
29 CFR 1910.305(f)(1): Insulation. All conductors used for general wiring shall be insulated unless otherwise permitted in this subpart.  On or about October 29, 2024, and at times prior to, on the east side wall of the middle bay of the metal rolling production area, the employer utilized an in-house fabricated cord set without insulation to power a garage door opener.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.305 G01 IV

Serious Gravity 5 2 instances 1 exposed
Issued
Apr 14, 2025
Abate by
May 1, 2025
Penalty
Initial $0 · Current $0
29 CFR 1910.305(g)(1)(iv): Flexible cords and/ or cables were used for purposes prohibited by paragraphs (A) through (F) of 29 CFR 1910.305(g)(1)(iv)(a).  a. On or about October 29, 2024, and at times prior to, on the west side wall of the middle bay of the metal rolling production area, flexible cable conduit was run through a wall hole from the disconnect switch to the Webb metal plate roller.  b. On or about October 29, 2024, and at times prior to, on the east side wall of the middle bay of the metal rolling production area, the employer utilized a fabricated cord set tun through a raceway to power the garage door leading outside.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.305 G02 III

Serious Gravity 5 1 instance 1 exposed
Issued
Apr 14, 2025
Abate by
May 1, 2025
Penalty
Initial $0 · Current $0
29 CFR 1910.305(g)(2)(iii): Flexible cords and cables were not connected to devices and fittings so that strain relief was provided that would prevent pull from being directly transmitted to joints or terminal screws.  On or about October 29, 2024, and at times prior to, on the east side wall of the middle bay of the metal rolling production area, the employer utilized a fabricated cord set without a strain relief on male plug end to power a garage door opener for a door leading outside.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

View ACS Steel CO., LLC's full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 347850570.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.