On , OSHA opened a complaint safety inspection of CURTIN MARITIME CORP in 725 PIER T AVENUE, DB SALTA VERDE, LONG BEACH, CA 90802 (NAICS 336611). OSHA activity number 347866386.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Curtin Maritime Corp — free Get an email when a new federal OSHA severe-injury report for Curtin Maritime Corp is published. One employer, no account, unsubscribe in one click.
Site address
725 PIER T AVENUE, DB SALTA VERDE
City
LONG BEACH
State
CA
ZIP
90802
Mailing
P.O BOX 2531, LONG BEACH, CA 90801
Inspection type
Complaint (B)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
336611
Employees
60
Ownership type
A

10 citations on file for this inspection.

1910.134 D01 III

Deleted Serious Gravity 5 1 instance 7 exposed
Issued
Nov 29, 2024
Abate by
Mar 4, 2025
Penalty
Initial $8,816 · Current $0 Reduced
29 CFR  1910.134(d)(1)(iii): The employer did not identify and evaluate the respiratory hazard(s) in the workplace; including a reasonable estimate of employee exposures to respiratory hazards and identification of the contaminant's chemical state and physical form:  DB Salta Verde: On or about November 6, 2024, and at times prior thereto, employee(s) conducted painting and grinding operations. A reasonable estimate of employee exposures to respiratory hazards and identification of the contaminant's chemical state and physical form were not evaluated or identified. Employee(s) were potentially exposed to respiratory hazard(s).
Recent events (3)
  • — F (S) $0
  • — C (S) $8816
  • — Z (S) $8816

1910.134 D03 III B 2

Deleted Serious Gravity 5 1 instance 6 exposed
Issued
Nov 29, 2024
Abate by
Jan 10, 2025
Penalty
Initial $0 · Current $0
29 CFR 1910.134(d)(3)(iii)(B)(2): The employer did not implement a change schedule for respirators not equipped with an End of Service Life Indicator that would ensure cartridges were changed before the end of their service life:  DB Salta Verde: On or about November 6, 2024, and at times prior thereto, employee(s) used a 3M full face respirator with 3M? Organic Vapor Cartridge/Filter 60921, P100 filters for painting operations. A change out schedule that was not based on objective information or data that would ensure that canisters and cartridges are changed before the end of their service life. Employees were potentially exposed to respiratory hazards.
Recent events (3)
  • — F (S) $0
  • — C (S) $0
  • — Z (S) $0

1910.134 H01 I

Other-than-serious Gravity 1 2 instances 2 exposed
Issued
Nov 29, 2024
Abate by
Jan 3, 2025
Penalty
Initial $0 · Current $5,290
29 CFR 1910.134(h)(1)(i): Respirators issued for the exclusive use of an employee were not cleaned and disinfected as often as necessary to be maintained in a sanitary condition:  DB Salta Verde: On or about November 6, 2024, and at times prior thereto, employees used a 3M full face respirators with P100 filters for painting operations. The respirators were not cleaned and disinfected as often as necessary to be maintained in a sanitary condition.  Employees were potentially exposed to skin irritation.
Recent events (3)
  • — F (O) $5290
  • — C (S) $0
  • — Z (S) $0

1910.134 H04

Other-than-serious Gravity 1 1 instance 1 exposed
Issued
Nov 29, 2024
Abate by
Jan 10, 2025
Penalty
Initial $0 · Current $0
29 CFR 1910.134(h)(4): Respirators that failed an inspection or were otherwise found to be defective were not removed from service and discarded or repaired:  DB Salta Verde: On or about November 6, 2024, and at times prior thereto, the face piece inside the 3M full face respirator with 3M? Organic Vapor Cartridge/Filter 60921, P100 was distorted and not removed from service. Employee(s) were potentially exposed to respiratory hazard(s).
Recent events (3)
  • — F (O) $0
  • — C (S) $0
  • — Z (S) $0

1915.77 C

Other-than-serious Gravity 5 1 instance 1 exposed
Issued
Nov 29, 2024
Penalty
Initial $8,816 · Current $4,231 Reduced
29 CFR  1915.77(c):- When employees were working aloft, or elsewhere at elevations more than 5 feet above a solid surface, either scaffolds or a sloping ladder, meeting the requirements of Subpart E- Scaffolds, Ladders, and Other Working Surfaces, were not provided to afford safe footing, and the employees were not protected by safety belts and lifelines meeting the requirements of 1915.159 and 1915.160:  DB Salta Verde, Top deck, on top of external fuel tank: On or about November 6, 2024, and at times prior thereto, employee(s) were working approximately 28 feet above a solid surface with an unguarded ledge and no fall protection. Employee(s) were exposed to fall hazard(s).
Recent events (3)
  • — F (O) $4231
  • — C (S) $8816
  • — Z (S) $8816

1915.132 D

Other-than-serious Gravity 5 1 instance 6 exposed
Issued
Nov 29, 2024
Abate by
Dec 26, 2024
Penalty
Initial $7,052 · Current $4,231 Reduced
29 CFR 1915.132(d): Worn and or frayed electric cables were not taken out of service.  DB Salta Verde, Top deck: On or about November 6, 2024, and at times prior thereto, employee(s) used a Makita grinder, model GA4553R, SN 2158 to grind off paint. The Makita grinder had a frayed electric cable and was not put out of service. Employee(s) were potentially exposed to electrical hazard(s).
Recent events (3)
  • — F (O) $4231
  • — C (S) $7052
  • — Z (S) $7052

1915.159 C05

Other-than-serious Gravity 5 1 instance 50 exposed
Issued
Nov 29, 2024
Abate by
Dec 26, 2024
Penalty
Initial $8,816 · Current $5,290 Reduced
29 CFR 1915.159(c)(5): Defective fall arrest system components were not removed from service.  DB Salta Verde: On or about November 6, 2024, and at times prior thereto, employee(s) used a 3M DBI-SALA Fall Protection Harness: Vest Harness, Quick-Connect model 1402021 to conduct painting operations from a boom lift. The fall harness was deteriorated with holes in the left hand and right hand leg straps and was not removed from service. Employee(s) were potentially exposed to fall hazard(s).
Recent events (3)
  • — F (O) $5290
  • — C (S) $8816
  • — Z (S) $8816

1915.159 D

Deleted Serious Gravity 5 1 instance 50 exposed
Issued
Nov 29, 2024
Abate by
Jan 3, 2025
Penalty
Initial $0 · Current $0
29 CFR 1915.159(d): Affected employees were not trained so that they could demonstrate the proper use, inspection, and storage of their fall arrest equipment.  DB Salta Verde: On or about November 6, 2024, and at times prior thereto, employee(s) were not trained to demonstrate proper inspection of the personal fall arrest equipment. Employee(s) were potentially exposed to fall hazard(s).
Recent events (3)
  • — F (S) $0
  • — C (S) $0
  • — Z (S) $0

1915.159 C07

Deleted Serious Gravity 5 1 instance 50 exposed
Issued
Nov 29, 2024
Abate by
Jan 10, 2025
Penalty
Initial $0 · Current $0
29 CFR 1915.159(c)(7): The employer shall provide for prompt rescue of employees in the event of a fall or shall ensure that employees are able to rescue themselves.  DB Salta Verde: On or about November 6, 2024, and at times prior thereto, employee(s) used personal fall protection and life lines to work above 5 feet with a boom lift. In the event of a fall the employer did not provide for prompt rescue of each employee. Employee(s) were potentially exposed to orthostatic intolerance hazards.
Recent events (3)
  • — F (S) $0
  • — C (S) $0
  • — Z (S) $0

1915.35 B09

Deleted Other-than-serious 1 instance 7 exposed
Issued
Nov 29, 2024
Abate by
Jan 10, 2025
Penalty
Initial $0 · Current $0
29 CFR 1915.35(b)(9): The face, eyes, head, and all other exposed parts of the body of employees who handled highly volatile paints were not protected.  DB Salta Verde: On or about November 6, 2024, and at times prior thereto, employees used highly volatile paints such as, Jotun Hardtop XP, COMP A/B and AMERCOAT 235 DARK GRAY 26008/AMERCOAT 235 CURE. Employee(s) who handled these highly volatile paints did not protect their arms. Employee(s) were potentially exposed to dermal hazard(s).
Recent events (3)
  • — F (O) $0
  • — C (O) $0
  • — Z (O) $0

View Curtin Maritime Corp's full OSHA safety record →