MANITOWOC, WI —
OSHA Inspection: ENLIGHT GROUP II LLC
Referral inspection · Safety discipline
At a glance
On , OSHA opened a referral safety inspection of ENLIGHT GROUP II LLC in 6311 WEST CUSTER STREET, MANITOWOC, WI 54220 (NAICS 332992). OSHA activity number 347887747.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- ENLIGHT GROUP II LLC
- Site address
- 6311 WEST CUSTER STREET
- City
- MANITOWOC
- State
- WI
- ZIP
- 54220
- Mailing
- 6311 W CUSTER STREET, MANITOWOC, WI 54220
What kind of inspection was it?
- Inspection type
- Referral (C)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 332992
- Employees
- 240
- Ownership type
- A
Citations
1 citation on file for this inspection.
1910.147 D
- Issued
- Feb 7, 2025
- Abate by
- Mar 10, 2025
- Penalty
- Initial $16,385 · Current $16,385
General-duty citation text
29 CFR 1910.147(d): The established procedure for the application of energy control (the lockout or tagout procedures) did not cover the actions listed in and was not done in sequence as required by 29 CFR 1910.147(d)(1)-(6): On or about November 11, 2024, at the facility located at 6311 West Custer Street, Manitowoc, Wisconsin; employees were exposed to machine hazards associated with moving parts when they engaged in servicing and maintenance activities on the Chain Annealer (602). The employer did not ensure that employees implemented energy control application steps or equivalent protective measures prior to allowing them to clear jammed casings. The machine was not deenergized prior to employees engaging in service/maintenance activities and the employee suffered an amputation injury to their right index finger. As a result, the remaining applicable energy control elements, involving machine isolation [1910.147(d)(3)], lockout/tagout device application [1910.147(d)(4)], dissipation of residual energy [1910(d)(5)(i)], and verification of isolation [1910.147(d)(6)] were not implemented to protect employees from machine hazards.
Recent events (1)
- — Z (S) $16385
More inspections at Enlight Group II LLC
View Enlight Group II LLC's full OSHA safety record →
More inspections in this industry (NAICS 332992)
More inspections in WI
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 347887747.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.