APPLETON, WI —
OSHA Inspection: QUAKER BAKERY BRANDS, INC.
Complaint inspection · Safety discipline
At a glance
On , OSHA opened a complaint safety inspection of QUAKER BAKERY BRANDS, INC. in 1207 N. MASON ST., APPLETON, WI 54914 (NAICS 311812). OSHA activity number 347915779.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- QUAKER BAKERY BRANDS, INC.
- Site address
- 1207 N. MASON ST.
- City
- APPLETON
- State
- WI
- ZIP
- 54914
- Mailing
- P.O. BOX 1016, APPLETON, WI 54914
What kind of inspection was it?
- Inspection type
- Complaint (B)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 311812
- Employees
- 70
- Ownership type
- A
Citations
3 citations on file for this inspection.
1910.147 C04 I
- Issued
- Jan 17, 2025
- Abate by
- Feb 11, 2025
- Penalty
- Initial $6,190 · Current $4,333 Reduced
General-duty citation text
29 CFR 1910.147(c)(4)(i): Procedures shall be developed, documented and utilized for the control of potentially hazardous energy when employees are engaged in the activities covered by this section: On or about December 5, 2024, at a workplace located at 1207 N. Mason Street, Appleton, Wisconsin in the Bakery and Pizza Department; the employer did not develop, document, and utilize equipment specific machine energy control procedures for equipment including but not limited to, the Cryogen freezer, industrial mixers, and ovens, exposing employees engaged in servicing and/or maintenance tasks, including but not limited to, cleaning and sanitizing equipment, to accidental and/or inadvertent restart of the equipment. Note: Exception: The employer need not document the required procedure for a particular machine or equipment, when all of the following elements exist: (1) The machine or equipment has no potential for stored or residual energy or reaccumulation of stored energy after shut down which could endanger employees; (2) the machine or equipment has a single energy source which can be readily identified and isolated; (3) the isolation and locking out of that energy source will completely deenergize and deactivate the machine or equipment; (4) the machine or equipment is isolated from that energy source and locked out during servicing or maintenance; (5) a single lockout device will achieve a locker-out condition; (6) the lockout device is under the exclusive control of the authorized employee performing the servicing or maintenance; (7) the servicing or maintenance does not create hazards for other employees; and (8) the employer, in utilizing this exception, has had no accidents involving the unexpected activation or reenergization of the machine or equipment during servicing or maintenance.
Recent events (2)
- — I (S) $4333
- — Z (S) $6190
1910.147 C07 IV
- Issued
- Jan 17, 2025
- Abate by
- Feb 3, 2025
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.147(c)(7)(iv): The employer shall certify that employee training has been accomplished and is being kept up to date. The certification shall contain each employee's name and dates of training: On or about December 5, 2024, at a workplace located at 1207 N. Mason Street, Appleton, Wisconsin in the Bakery and Pizza Department; the employer did not certify that each authorized employees performing servicing and/or maintenance tasks were trained on the employer's energy control procedures and hazardous energy sources.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.147 D04 I
- Issued
- Jan 17, 2025
- Abate by
- Feb 3, 2025
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.147(d)(4)(i): Lockout or tagout devices shall be affixed to each energy isolating device by authorized employees: On or about December 4, 2024, at a workplace located at Mason Street, Appleton, Wisconsin, employees engaged in cleaning and sanitation activities including but not limited to, wiping down the inside of machinery near rotating parts and in-running nip points did not affix a lockout device to each energy isolating device.
Recent events (2)
- — I (S) $0
- — Z (S) $0
More inspections at Quaker Bakery Brands, INC.
View Quaker Bakery Brands, INC.'s full OSHA safety record →
More inspections in this industry (NAICS 311812)
More inspections in WI
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 347915779.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.