CATOOSA, OK ·
OSHA Inspection: SOONER COATING, LLC
Referral inspection · Health discipline
At a glance
On , OSHA opened a referral health inspection of SOONER COATING, LLC in 832 W VERDIGRIS PARKWAY, CATOOSA, OK 74015 (NAICS 332813). OSHA activity number 347926412.
OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- SOONER COATING, LLC
- Site address
- 832 W VERDIGRIS PARKWAY
- City
- CATOOSA
- State
- OK
- ZIP
- 74015
- Mailing
- 832 W VERDIGRIS PARKWAY, CATOOSA, OK 74015
What kind of inspection was it?
- Inspection type
- Referral (C)
- Scope
- Partial (B)
- Discipline
- Health
- Advance notice
- No
- Union status
- Non-union (B)
When did the case open and close?
- Opened
- Closing conference
- Last modified
- Data loaded
Establishment context
- NAICS code
- 332813
- Employees
- 20
- Ownership type
- Private (A)
Citations
3 citations on file for this inspection.
1910.134 I05 I
- Issued
- May 22, 2025
- Abate by
- Jun 11, 2025
- Penalty
- Initial $3,783 · Current $1,600 Reduced
General-duty citation text
29 CFR 1910.134(i)(5)(i): Compressors used to supply breathing air to respirators were not so constructed and situated so as to prevent entry of contaminated air into the air-supply system: On or about December 9, 2024, and at times prior thereto, in the abrasive blasting area, employees were performing abarsive blasting work activities and dedicated supplied air lines were not available for the supplied air respirators in use by the employees.
Recent events (2)
- · I (S) $1600
- · Z (S) $3783
1910.134 I07
- Issued
- May 22, 2025
- Abate by
- Jun 11, 2025
- Penalty
- Initial $4,729 · Current $2,100 Reduced
General-duty citation text
29 CFR 1910.134(i)(7): Oil lubricated compressor(s) used to supply breathing air did not have a high-temperature or carbon monoxide alarm(s) or both: On or about December 9, 2024, and at times prior thereto, in the abrasive blasting area, employees were in use of supplied air respirators while performing abarsive blasting work activities and the supplied breathing air coming from an oil lubricated compressor did not have a functioning carbon monoxide alarm.
Recent events (2)
- · I (S) $2100
- · Z (S) $4729
1910.244 B
- Issued
- May 22, 2025
- Abate by
- Jun 11, 2025
- Penalty
- Initial $2,837 · Current $1,400 Reduced
General-duty citation text
29 CFR 1910.244(b): The operating valve(s) on abrasive blast cleaning nozzle(s) were not held open manually: On or about December 9, 2024, and at times prior thereto, in the abrasive blasting area, operating valves on the abrasive blasting nozzles were held open by the use of a rubber glove tied around the nozzle.
Recent events (2)
- · I (S) $1400
- · Z (S) $2837
More inspections at Sooner Coating, LLC
View Sooner Coating, LLC's full OSHA safety record →
More inspections in this industry (NAICS 332813)
More inspections in OK
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). OSHA publishes its own view of this case as inspection number 347926412.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.