OSHA Inspection: GRAND PRAIRIE FOODS, INC.

Complaint inspection · Safety discipline

On , OSHA opened a complaint safety inspection of GRAND PRAIRIE FOODS, INC. in 4200 EAST PRODUCER LANE, SIOUX FALLS, SD 57104 (NAICS 311991). OSHA activity number 347929978.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Grand Prairie Foods, INC. — free Get an email when a new federal OSHA severe-injury report for Grand Prairie Foods, INC. is published. One employer, no account, unsubscribe in one click.
Site address
4200 EAST PRODUCER LANE
City
SIOUX FALLS
State
SD
ZIP
57104
Mailing
4200 EAST PRODUCER LANE, SIOUX FALLS, SD 57104
Inspection type
Complaint (B)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
311991
Employees
15
Ownership type
A

3 citations on file for this inspection.

5(a)(1)

Deleted Serious Gravity 5 2 instances 3 exposed
Issued
Apr 17, 2025
Abate by
May 19, 2025
Penalty
Initial $10,853 · Current $0 Reduced
OSH ACT of 1970 Section (5)(a)(1): Section 5(a)(1) of the Occupational Safety and Health Act of 1970: The employer did not furnish employment and a place of employment which was free from recognized hazards that were causing or likely to cause death or serious physical harm to employees in that employees were exposed to struck-by and crushing hazards:  a) Grand Prairie Foods, Inc. at 4200 East Producer Lane, Sioux Falls, SD 57104: On or about and at times prior to December 11, 2024, the employer did not ensure employees were protected from struck-by and crushing hazards in that the pallet racking system located in the warehouse and cooler warehouse, had multiple areas of damage to include, but not limited to, the horizontal bracing, diagonal bracing, column post, and base plates.  This condition exposed employees to struck-by and crushing hazards.  Abatement Note: Among other methods, one feasible and acceptable abatement methods to correct this hazard are to follow American National Standards Institute (ANSI) and Rack Manufacturers Institute (RMI)-ANSI-RMI MH 16:1-2012, "Specification for the Design, Testing and Utilization of Industrial Steel Storage Racks." Under paragraph 1.4.1 Owner Maintenance, (2)"Regularly inspect for damage. If damage is found, immediately isolate the affected area. Have a storage rack design professional evaluate the damage and unload, replace or repair if directed by the professional, any damaged columns, beams, or other structural component to restore the system to at least its original design capacity." Additionally, under paragraph 1.4.9 Rack Damage, "Upon any visible damage, the pertinent portions of the rack shall be immediately isolated by the user until the damaged portion is evaluated by a storage rack design professional. Before allowing the rack to be placed into service the design professional must certify that the rack system and/or the repaired components have been restored to at least their original design capacity.
Recent events (2)
  • — I (S) $0
  • — Z (S) $10853

1910.303 G01

Other-than-serious Gravity 1 1 instance 3 exposed
Issued
Apr 17, 2025
Abate by
May 19, 2025
Penalty
Initial $5,426 · Current $5,426
29 CFR 1910.303(g)(1): The employer did not ensure that space about electric equipment and or sufficient access and working space was provided and maintained about all electric equipment to permit ready and safe operation and maintenance of such equipment:  (a)Grand Prairie Foods at 4200 East Producer Lane, Sioux Falls, SD 57104: On or about and at times prior to December 10, 2024, the employer did not ensure that space about electric equipment and or sufficient access and working space was provided and maintained from the front of an electrical panel on the west wall.  This condition exposed employees to electrical hazards.
Recent events (2)
  • — I (O) $5426
  • — Z (S) $5426

1910.305 B02 I

Other-than-serious Gravity 1 1 instance 3 exposed
Issued
Apr 17, 2025
Abate by
May 19, 2025
Penalty
Initial $0 · Current $0
29 CFR 1910.305(b)(2)(i): Each outlet box in completed installations did not have a cover, faceplate, or fixture canopy:  (a)Grand Prairie Foods, Inc. at 4200 East Producer Lane, Sioux Falls, SD 57104: On or about and at times prior to December 11, 2024, the employer did not ensure that a side plate adequately covered the electrical components on an outlet located inside the cooler room on the south wall.  This condition exposed employees to electrical hazards.