CLOSTER, NJ —
OSHA Inspection: CAPITAL HARDWARE SUPPLY, INC.
Complaint inspection · Health discipline
At a glance
On , OSHA opened a complaint health inspection of CAPITAL HARDWARE SUPPLY, INC. in 10 RAILROAD AVENUE, CLOSTER, NJ 07624 (NAICS 332322). OSHA activity number 347930778.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- CAPITAL HARDWARE SUPPLY, INC.
- Site address
- 10 RAILROAD AVENUE
- City
- CLOSTER
- State
- NJ
- ZIP
- 07624
- Mailing
- 10 RAILROAD AVENUE, CLOSTER, NJ 07624
What kind of inspection was it?
- Inspection type
- Complaint (B)
- Scope
- Partial (B)
- Discipline
- Health
- Advance notice
- No
- Union status
- A
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 332322
- Employees
- 150
- Ownership type
- A
Citations
5 citations on file for this inspection.
1910.37 B04
- Issued
- Feb 27, 2025
- Penalty
- Initial $7,022 · Current $4,213 Reduced
General-duty citation text
29 CFR 1910.37(b)(4): Signs were not posted along the exit access indicating the direction of travel to the nearest exit and exit discharge when the direction of travel to the exit or exit discharge was not immediately apparent: a) Production Area: Directional exit sign was not installed to assist employees in a case of emergency evacuation, on or about 12/12/2024.
Recent events (2)
- — I (O) $4213.2
- — Z (S) $7022
1910.134 C02 II
- Issued
- Feb 27, 2025
- Penalty
- Initial $7,022 · Current $4,213 Reduced
General-duty citation text
29 CFR 1910.134(c)(2)(ii): The employer did not establish and implement those elements of a written program necessary to ensure that any employee using a respirator voluntarily was medically able to use that respirator, and that the respirator was cleaned, stored, and maintained so that its use does not present a health hazard to the user: a) Production area: Employer permitted an employee to use his own 3M half-face elastomeric respirator voluntarily and did not provide a medical evaluation to determine the employee's ability to use the respirator, on or about 12/12/2024.
Recent events (2)
- — I (S) $4213.2
- — Z (S) $7022
1910.157 E03
- Issued
- Feb 27, 2025
- Penalty
- Initial $7,022 · Current $4,213 Reduced
General-duty citation text
29 CFR 1910.157(e)(3): The annual maintenance record was not available to the Assistant Secretary upon request: a) Entrance lobby: A portable fire extinguisher was not subjected to an annual maintenance check and did not have a maintenance/inspection tag on or about 12/18/2024.
Recent events (2)
- — I (S) $4213.2
- — Z (S) $7022
1910.1200 E01 I
- Issued
- Feb 27, 2025
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.1200(e)(1)(i): The employer did not compile a list of the hazardous chemicals known to be present using a product identifier that was referenced on the appropriate safety data sheet: a) Facility: The company Hazard Communication program did not have a list of hazardous materials, including stainless steel, known to be located at the workplace, on or about 12/12/24.
Recent events (2)
- — I (O) $0
- — Z (O) $0
1910.1200 H02 III
- Issued
- Feb 27, 2025
- Abate by
- Mar 25, 2025
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.1200(h)(2)(iii): The employer did not provide information to the employees as to the location and availability of the written hazard communication program, and material safety data sheets required by 29 CFR 1910.1200: a) Facility: The employer did not provide information to the employees as to the location and availability of the written hazard communication programs, when the employees were exposed to hazardous chemicals including stainless steel welding fume, on or about 12/12/24.
Recent events (2)
- — I (O) $0
- — Z (O) $0
More inspections at Capital Hardware Supply, INC.