SAVANNAH, GA —
OSHA Inspection: CARBONE TECHNOLOGY, INC.
Complaint inspection · Safety discipline
At a glance
On , OSHA opened a complaint safety inspection of CARBONE TECHNOLOGY, INC. in 1624 DEAN FOREST RD, SAVANNAH, GA 31408 (NAICS 334511). OSHA activity number 347945321.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- CARBONE TECHNOLOGY, INC.
- Site address
- 1624 DEAN FOREST RD
- City
- SAVANNAH
- State
- GA
- ZIP
- 31408
- Mailing
- 1624 DEAN FOREST RD, SAVANNAH, GA 31408
What kind of inspection was it?
- Inspection type
- Complaint (B)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 334511
- Employees
- 32
- Ownership type
- A
Citations
6 citations on file for this inspection.
5(a)(1)
- Issued
- May 19, 2025
- Penalty
- Initial $5,627 · Current $0 Reduced
General-duty citation text
OSH ACT of 1970 Section (5)(a)(1):The employer did not furnish employment and a place of employment which were free from recognized hazards that were causing or likely to cause death or serious physical harm to employees, in that employees are exposed to struck-by hazards while loads are dropped by cranes that have hooks with damaged throat latches. (A) Dip tank area: On or about December 19, 2024, the employer exposed employees to a struck by hazard in that the lifting hook on a Dayton Overhead Crane was damaged and not functioning. (B) Dip tank area: On or about December 19, 2024, the employer exposed employees to a struck by hazard in that the lifting hook on a Orley Meyer Overhead Crane was damaged and not functioning.
Recent events (2)
- — I (S) $0
- — Z (S) $5627
1910.22 A03
- Issued
- May 19, 2025
- Penalty
- Initial $4,220 · Current $2,901 Reduced
General-duty citation text
29 CFR 1910.22(a)(3):29 CFR 1910.22(a)(3): The employer did not ensure that walking-working surfaces are maintained free of hazards such as sharp or protruding objects, loose boards, corrosion, leaks, spills, snow, and ice. A) Wash Booth: On or about December 19, 2024, the employer exposed employees to a trip hazard in that the metal threshold across the front of the wash area was torn and bent upward.
Recent events (2)
- — I (O) $2901.22
- — Z (S) $4220
1910.107 B05 IV
- Issued
- May 19, 2025
- Abate by
- Jul 31, 2025
- Penalty
- Initial $0 · Current $3,869
General-duty citation text
29 CFR 1910.107(b)(5)(iv): Space within the spray booth on the downstream and upstream sides of filters were not protected with approved automatic sprinklers: A) Paint Spray Booth: On or about December 19, 2024, the employer exposed employees to a fire hazard in that there were no automatic sprinklers on the downstream and upstream sides of the spray booth filters.
Recent events (2)
- — I (S) $3868.53
- — Z (S) $0
1910.107 A05 III
- Issued
- May 19, 2025
- Penalty
- Initial $5,627 · Current $3,869 Reduced
General-duty citation text
29 CFR 1910.107(a)(5)(iii): A dry spray booth did not have sufficient dry filters to minimize dusts or residues from entering exhaust ducts: A) Paint Spray Booth: On or about December 19, 2024, the employer exposed employees to a fire hazard in that there were insufficient dry filters to minimize the amount of dust and residue from entering exhaust duct.
Recent events (2)
- — I (O) $3868.53
- — Z (S) $5627
1910.107 C06
- Issued
- May 19, 2025
- Abate by
- Jun 24, 2025
- Penalty
- Initial $5,627 · Current $0 Reduced
General-duty citation text
29 CFR 1910.107(c)(6): Electrical wiring and equipment not subject to deposits of combustible residues but located in a spraying area as herein defined were not explosion-proof type approved for Class I, group D locations and did not otherwise conform to the provisions of subpart S of this part, for Class I, Division 1, Hazardous Locations: A) Paint Spray Booth: On or about December 19, 2024, the employer exposed employees to a fire hazard in that the quadruplex electrical receptacle box located on the front of the spray booth was not designed for a flammable spray paint area.
Recent events (2)
- — I (O) $0
- — Z (S) $5627
1910.212 A01
- Issued
- May 19, 2025
- Penalty
- Initial $7,035 · Current $4,837 Reduced
General-duty citation text
29 CFR 1910.212(a)(1): Machine guarding was not provided to protect operator(s) and other employees from hazards created by in-going nip points, rotating parts, and/or flying chips and sparks: A) Machine shop area: On or about December 19, 2024, the employer exposed employees to a caught-in hazard, in that the rotating chucks on two Monarch Metal Lathe machines and a Yamazaki Machinery Works metal lathe did not have a guard over the top of the chucks.
Recent events (2)
- — I (S) $4836.52
- — Z (S) $7035
More inspections at Carbone Technology, INC.
View Carbone Technology, INC.'s full OSHA safety record →
More inspections in this industry (NAICS 334511)
More inspections in GA
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 347945321.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.