OSHA Inspection: INDUSTRIAL SERVICE & INSTALLATION, INC.

Complaint inspection · Safety discipline

On , OSHA opened a complaint safety inspection of INDUSTRIAL SERVICE & INSTALLATION, INC. in 290 EMIG ROAD, EMIGSVILLE, PA 17318 (NAICS 333922). OSHA activity number 347977621.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Industrial Service & Installation, INC. — free Get an email when a new federal OSHA severe-injury report for Industrial Service & Installation, INC. is published. One employer, no account, unsubscribe in one click.
Site address
290 EMIG ROAD
City
EMIGSVILLE
State
PA
ZIP
17318
Mailing
P.O. BOX 436, EMIGSVILLE, PA 17318
Inspection type
Complaint (B)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
333922
Employees
60
Ownership type
A

2 citations on file for this inspection.

1910.178 L04 II A

Other-than-serious Gravity 5 1 instance 1 exposed
Issued
Mar 25, 2025
Abate by
Apr 11, 2025
Penalty
Initial $9,457 · Current $4,500 Reduced
1910.178(l)(4)(ii)(A)   Refresher training, including an evaluation of the effectiveness of that training, was not conducted as required after an operator was observed to operate the vehicle in an unsafe manner to ensure that the operator had the knowledge and skills needed to operate the powered industrial truck safely.   a) 290 Emig Road EMIGSVILLE, PA 17318 - a material handling employee was operating a Yale sit down powered industrial truck without utilizing a seatbelt, on or about January 15, 2025.  Abatement certification and documentation required within 10 days after abatement date. The certification shall include a statement that abatement is complete, the date and method of abatement, and state that employees and their representatives were informed of this abatement. Abatement documentation shall include documents demonstrating that abatement is complete, such as evidence of the purchase or repair of equipment, photographic or video evidence of abatement or other written records.
Recent events (2)
  • — I (O) $4500
  • — Z (S) $9457

1910.334 A02 II

Other-than-serious Gravity 1 1 instance 2 exposed
Issued
Mar 25, 2025
Abate by
Apr 11, 2025
Penalty
Initial $4,965 · Current $3,000 Reduced
29 CFR 1910.334(a)(2)(ii): There was a defect or evidence of damage that could have exposed an employee to injury and the defective or damaged item was not removed from service.  a) 290 Emig Road EMIGSVILLE, PA 17318 - Employees were exposed to electrical hazards while conducting metal fabrication operations due to a damaged flexible power cord attached to a Continental Dynamics floor fan (Model 42-5559), located across from the paint booth, on or about January 15, 2025.  Abatement certification required within 15 days after abatement date. The certification shall include a statement that abatement is complete, date and method of abatement, and states employees and their representatives were informed of this abatement.
Recent events (2)
  • — I (O) $3000
  • — Z (S) $4965

View Industrial Service & Installation, INC.'s full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 347977621.