EMIGSVILLE, PA —
OSHA Inspection: INDUSTRIAL SERVICE & INSTALLATION, INC.
Complaint inspection · Health discipline
At a glance
On , OSHA opened a complaint health inspection of INDUSTRIAL SERVICE & INSTALLATION, INC. in 290 EMIG ROAD, EMIGSVILLE, PA 17318 (NAICS 333922). OSHA activity number 347980716.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- INDUSTRIAL SERVICE & INSTALLATION, INC.
- Site address
- 290 EMIG ROAD
- City
- EMIGSVILLE
- State
- PA
- ZIP
- 17318
- Mailing
- P.O. BOX 436, EMIGSVILLE, PA 17318
What kind of inspection was it?
- Inspection type
- Complaint (B)
- Scope
- Partial (B)
- Discipline
- Health
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 333922
- Employees
- 60
- Ownership type
- A
Citations
5 citations on file for this inspection.
1910.151 C
- Issued
- Mar 25, 2025
- Penalty
- Initial $4,220 · Current $4,500
General-duty citation text
29 CFR 1910.151(c): Where employees were exposed to injurious corrosive materials, suitable facilities for quick drenching or flushing of the eyes and body were not provided within the work area for immediate emergency use. a) 290 Emig Road, York, PA 17406 - On or about January 15, 2025, employees were using chemicals such as KEM AQUA 8710 Enamel and BOND-PLEX Water Based Coating and the eyewash station was blocked by materials preventing employees from immediate access in case of an emergency. Abatement certification required within 10 days after abatement date. The certification shall include a statement that abatement is complete, date and method of abatement, and states that employees and their representatives were informed of this abatement.
Recent events (2)
- — I (O) $4500
- — Z (S) $4220
1910.134 E01
- Issued
- Mar 25, 2025
- Penalty
- Initial $6,620 · Current $0 Reduced
General-duty citation text
29 CFR 1910.134(e)(1): The employer did not provide a medical evaluation to determine the employee's ability to use a respirator, before the employee was fit tested or required to use the respirator in the workplace. a) 290 Emig Road York PA 17318 - Employee(s) were observed painting parts in the paint booth and were required by the employer to wear a 3M Model 5203 Half-Face Respirator but had not been medically cleared by a physician or other licensed healthcare professional (PLHCP) to wear the respirator prior to conducting work. b) 290 Emig Road York PA 17318 - Employee(s) were fit tested on the 3M Model 5203 Half-Face Respirator but had not been medically cleared by a physician or other licensed healthcare professional (PLHCP) to wear the respirator prior to conducting the fit test. Abatement certification required within 10 days after abatement date. The certification shall include a statement that abatement is complete, date and method of abatement, and states employees and their representatives were informed of this abatement.
Recent events (2)
- — I (S) $0
- — Z (S) $6620
1910.134 F01
- Issued
- Mar 25, 2025
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.134(f)(1): The employer did not ensure that employee(s) required to use a tight-fitting facepiece respirator passed the appropriate qualitative fit test (QLFT) or quantitative fit test (QNFT). a) 290 Emig Road, York, PA 17406 - On or about January 15, 2025, employees were wearing a tight-fighting half-face respirator and were not provided with a qualitative or quantitative fit test prior to use. Abatement certification required within 10 days after abatement date. The certification shall include a statement that abatement is complete, date and method of abatement, and states that employees and their representatives were informed of this abatement.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.134 K
- Issued
- Mar 25, 2025
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.134(k): The employer did not provide comprehensive, understandable training which did not occur annually and/or more often if necessary. a) 290 Emig Road, York, PA 17406 - On or about January 15, 2025, employee(s) were wearing a tight-fighting half-face respirator and were not provided with a respiratory protection training prior to respirator use. Abatement certification required within 10 days after abatement date. The certification shall include a statement that abatement is complete, date and method of abatement, and states that employees and their representatives were informed of this abatement.
Recent events (2)
- — I (O) $0
- — Z (S) $0
1910.1200 F06 II
- Issued
- Mar 25, 2025
- Abate by
- Apr 18, 2025
- Penalty
- Initial $6,620 · Current $4,500 Reduced
General-duty citation text
29 CFR 1910.1200(f)(6)(ii): Except as provided in 29 CFR 1910.1200(f)(7) and 29 CFR 1910.1200(f)(8), the employer did not ensure that each container of hazardous chemicals in the workplace was labeled, tagged or marked with the product identifier and words, pictures, symbols, or combination thereof, which provide at least general information regarding the hazards of the chemicals and which, in conjunction with the other information immediately available to employees under the hazard communication program, would provide employees with the specific information regarding the physical and health hazards of the hazardous chemical. a) 290 Emig Road, York, PA 17406 - On or about January 15, 2025, the employer did not ensure that spray bottles containing various cleaning chemicals were properly labeled. Abatement certification required within 10 days after abatement date. The certification shall include a statement that abatement is complete, date and method of abatement, and states that employees and their representatives were informed of this abatement.
Recent events (2)
- — I (O) $4500
- — Z (S) $6620
More inspections at Industrial Service & Installation, INC.
View Industrial Service & Installation, INC.'s full OSHA safety record →
More inspections in this industry (NAICS 333922)
More inspections in PA
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 347980716.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.