OSHA Inspection: LIONI LATTICINI INC.

Referral inspection · Safety discipline

On , OSHA opened a referral safety inspection of LIONI LATTICINI INC. in 555 LEHIGH AVE, UNION, NJ 07083 (NAICS 311513). OSHA activity number 347990939.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Lioni Latticini INC. — free Get an email when a new federal OSHA severe-injury report for Lioni Latticini INC. is published. One employer, no account, unsubscribe in one click.
Site address
555 LEHIGH AVE
City
UNION
State
NJ
ZIP
07083
Mailing
555 LEHIGH AVE, UNION, NJ 07083
Inspection type
Referral (C)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
311513
Employees
85
Ownership type
A

3 citations on file for this inspection.

1910.147 C06 II

Serious Gravity 5 1 instance 1 exposed
Issued
Jul 17, 2025
Abate by
Aug 12, 2025
Penalty
Initial $9,931 · Current $9,931
29 CFR  1910.147(c)(6)(ii): The employer did not certify that the periodic inspections have been performed:   a.) Lioni Latticini Inc/555 Lehigh Ave, Union, NJ 07083/The employer did not conduct periodic inspections of each energy control procedure at least annually to verify that the specific procedures for equipment, such as the Fill-Tech machine, serial # FT-1549, were adequate and were being applied correctly.  Condition noted on or about 01/22/2025.
Recent events (1)
  • — Z (S) $9931

1910.147 C07 I

Serious Gravity 5 1 instance 1 exposed
Issued
Jul 17, 2025
Abate by
Aug 12, 2025
Penalty
Initial $9,931 · Current $9,931
29 CFR  1910.147(c)(7)(i): The employer did not provide training to ensure that the purpose and function of the energy control program are understood by employees and that the knowledge and skills required for the safe application, usage, and removal of the energy controls are acquired by employees:  a.)Lioni Latticini Inc/555 Lehigh Ave, Union, NJ 07083/ The employer did not train authorized or affected employees to ensure that the purpose and functions of the energy control program were understood.   Condition noted on or about  01/22/2025.
Recent events (1)
  • — Z (S) $9931

1910.212 A03 II

Serious Gravity 5 1 instance 1 exposed
Issued
Jul 17, 2025
Abate by
Aug 12, 2025
Penalty
Initial $9,931 · Current $9,931
29 CFR  1910.212(a)(3)(ii): Point of operation guards were not designed and constructed as to prevent the operator from having any part of their body in the danger zone during the operating cycle:  a) Lioni Latticini Inc/555 Lehigh Ave, Union, NJ 07083/The employer did not ensure that the Fill-Tech machine, serial # FT-1549 where the lids are placed on the mozzarella cups was guarded to protect against finger lacerations or finger crushing hazards.   Condition observed on or about 01/22/2025.
Recent events (1)
  • — Z (S) $9931

View Lioni Latticini INC.'s full OSHA safety record →