Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: STERLING ENGINEERING AND FABRICATION, INC.

Complaint inspection · Safety discipline

On , OSHA opened a complaint safety inspection of STERLING ENGINEERING AND FABRICATION, INC. in 101 JERRY DOWD DR., CARROLLTON, GA 30117 (NAICS 332312). OSHA activity number 347995664.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Sterling Engineering and Fabrication, INC. — free Get an email when a new federal OSHA severe-injury report for Sterling Engineering and Fabrication, INC. is published. One employer, no account, unsubscribe in one click.
Site address
101 JERRY DOWD DR.
City
CARROLLTON
State
GA
ZIP
30117
Mailing
101 JERRY DOWD DR., CARROLLTON, GA 30117
Inspection type
Complaint (B)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
332312
Employees
26
Ownership type
A

3 citations on file for this inspection.

1910.184 I01

Deleted Serious Gravity 5 1 instance 8 exposed
Issued
Jul 9, 2025
Abate by
Aug 6, 2025
Penalty
Initial $8,276 · Current $0 Reduced
29 CFR  1910.184(i)(1):Synthetic web sling(s) were not marked or coded to show rated capacities for each type of hitch and type of synthetic web material:  (a) On January 23, 2025, and times prior the employer exposed employees to struck-by hazards in that the employer did not ensure that synthetic slings identified the rated load capacity while employees used the slings to move steel beams on the production floor.
Recent events (2)
  • — I (S) $0
  • — Z (S) $8276

1910.184 I09 IV

Serious Gravity 10 1 instance 8 exposed
Issued
Jul 9, 2025
Abate by
Aug 6, 2025
Penalty
Initial $0 · Current $0
29 CFR  1910.184(i)(9)(iv): Synthetic web sling(s) with broken or worn stitches were not immediately removed from service:  (a) On January 23, 2025, and times prior the employer exposed employees to struck-by hazards in that the employer did not remove from service synthetic slings that showed signs of broken/worn stitches while employees used the slings to move steel beams on the production floor.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.252 B03

Serious Gravity 5 1 instance 8 exposed
Issued
Jul 9, 2025
Abate by
Aug 6, 2025
Penalty
Initial $9,931 · Current $9,105 Reduced
29 CFR  1910.252(b)(3):Employees exposed to the hazards created by welding, cutting, or brazing operations were not protected by personal protective equipment in accordance with the requirements of 29 CFR 1910.132:  a) Welding area: On January 23, 2025, and times prior, the employer exposed employees to burn hazards in that Personal Protected Equipment was not proved to protect the torso, exposing the employee to burns while torch/ welding/cutting task in the Welding area.
Recent events (2)
  • — I (S) $9105
  • — Z (S) $9931

View Sterling Engineering and Fabrication, INC.'s full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 347995664.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.