OSHA Inspection: STERLING ENGINEERING AND FABRICATION, INC.

Complaint inspection · Health discipline

On , OSHA opened a complaint health inspection of STERLING ENGINEERING AND FABRICATION, INC. in 101 JERRY DOWD DR., CARROLLTON, GA 30117 (NAICS 332312). OSHA activity number 347996076.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Sterling Engineering and Fabrication, INC. — free Get an email when a new federal OSHA severe-injury report for Sterling Engineering and Fabrication, INC. is published. One employer, no account, unsubscribe in one click.
Site address
101 JERRY DOWD DR.
City
CARROLLTON
State
GA
ZIP
30117
Mailing
101 JERRY DOWD DR., CARROLLTON, GA 30117
Inspection type
Complaint (B)
Scope
Partial (B)
Discipline
Health
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
332312
Employees
26
Ownership type
A

3 citations on file for this inspection.

1910.134 E01

Serious Gravity 1 1 instance 1 exposed
Issued
Jun 30, 2025
Penalty
Initial $4,965 · Current $2,979 Reduced
29 CFR  1910.134(e)(1): The employer did not provide a medical evaluation to determine the employee's ability to use a respirator, before the employee was fit tested or required to use the respirator in the workplace:   (a) Welding Area: On or about January 23, 2025, and at times prior, the employer exposed employees to respiratory hazards, in that a medical evaluation was not provided to employees when they were required to wear half-face respirators while welding on material such as carbon or stainless steel.
Recent events (2)
  • — I (S) $2979
  • — Z (S) $4965

1910.134 F01

Deleted Serious Gravity 1 1 instance 1 exposed
Issued
Jun 30, 2025
Penalty
Initial $0 · Current $0
29 CFR  1910.134(f)(1):The employer did not ensure that employee(s) required to use a tight-fitting facepiece respirator passed the appropriate qualitative fit test (QLFT) or quantitative fit test (QNFT):   (a) Welding Area: On or about January 23, 2025, and at times prior, the employer exposed employees to respiratory hazards, in that a FIT test was not provided to employees required to wear half face respirators while welding on material such as carbon or stainless steel.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.134 G01 I A

Deleted Serious Gravity 1 1 instance 1 exposed
Issued
Jun 30, 2025
Abate by
Jul 28, 2025
Penalty
Initial $0 · Current $0
29 CFR  1910.134(g)(1)(i)(A): Respirators with tight-fitting facepieces were worn by employees who had facial hair that came between the sealing surface of the facepiece and the face or that interfered with valve function:   (a) Welding Area: On or about January 23, 2025, and at times prior, the employer exposed an employee to respiratory hazards, in that  facial hair was not removed when the employees were required to wear respirators while welding on material such as carbon or stainless steel.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

View Sterling Engineering and Fabrication, INC.'s full OSHA safety record →