GALENA, KS —
OSHA Inspection: PBI-GORDON CORPORATION
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of PBI-GORDON CORPORATION in 7530 SE BOSTON MILLS ROAD, GALENA, KS 66739 (NAICS 325320). OSHA activity number 348015579.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- PBI-GORDON CORPORATION
- Site address
- 7530 SE BOSTON MILLS ROAD
- City
- GALENA
- State
- KS
- ZIP
- 66739
- Mailing
- 7530 SE BOSTON MILLS ROAD, GALENA, KS 66739
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Complete (A)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 325320
- Employees
- 40
- Ownership type
- A
Citations
5 citations on file for this inspection.
1910.157 E02
- Issued
- Mar 10, 2025
- Penalty
- Initial $5,426 · Current $3,256 Reduced
General-duty citation text
29 CFR 1910.157(e)(2): Portable fire extinguishers were not visually inspected at least monthly: Employees engaged in making pesticide products activities were exposed to burns, fire hazards in that fire extinguishers were not inspected monthly at the following instances: a) Building 1 by the front door - Employer did not inspect the fire extinguisher in December 2024. b) Building 1 in the back of the building - Employer did not inspect the fire extinguisher in December 2024. c) Building 6 - Employer did not inspect the fire extinguisher in December 2024. d) Fuel Tank area - Employer did not inspect the fire extinguisher in February, March, April, May, June, July and in December 2024.
Recent events (2)
- — I (S) $3255.6
- — Z (S) $5426
1910.212 A01
- Issued
- Mar 10, 2025
- Abate by
- Apr 3, 2025
- Penalty
- Initial $5,426 · Current $3,256 Reduced
General-duty citation text
29 CFR 1910.212(a)(1): One or more methods of machine guarding was not provided to protect the operator and other employees in the machine area from hazards such as those created by rotating parts and flying chips: Employees engaged in machining activities at the Evolution Mag Drill Press in the Maintenance Shop Building #6 were exposed to struck-by hazards in that machine guarding was not provided. The rotating drill chuck was not guarded, employees were not provided protection from flying chips and debris.
Recent events (2)
- — I (S) $3255.6
- — Z (S) $5426
1910.303 F02
- Issued
- Mar 10, 2025
- Abate by
- Apr 3, 2025
- Penalty
- Initial $5,426 · Current $3,256 Reduced
General-duty citation text
29 CFR 1910.303(f)(2): Each service, feeder, and branch circuit, at its disconnecting means or overcurrent device, was not legibly marked to indicate its purpose, nor located and arranged so the purpose was evident: Employees performing servicing and maintenance operations were exposed to burns, electrical shock hazards in that the following Electric Disconnects and Breakers missing labels to identify what they service: a) Building #1, the Double D Square safety switch box was not labeled. b) Building #3, the 240VAC 1PH Service Disconnect box was not label. c) Building #9, the 480V Double D safety switch box was not labeled. d) Outdoor Poll - Fuel Tank area, the Eaton Cutler-Hammer Heavy Duty Safety Switch box was not labeled. e) Building #11, the circuit breaker slots #1 and #5 were not labeled.
Recent events (2)
- — I (S) $3255.6
- — Z (S) $5426
1910.178 A06
- Issued
- Mar 10, 2025
- Abate by
- Apr 3, 2025
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.178(a)(6): The employer did not ensure that all nameplates and markings were in place and maintained in a legible condition: Employees engaged in material handing activities using the following forklifts were exposed to struck-by hazards in that the following markings were not in place and legible: a) Building #3 - The control lever for the Nissan 40 forklift, M#MCP1F1A20LV S#9N0293, was not legibly marked. b) Maintenance Shop Building #6 - The control lever for the Nissan forklift M#MCP1F2A25LV S#9W2362, all three levers worn out, were not legibly marked. c) Building #7 - The control lever for the Nissan 50 forklift M# MCUL02A25LV S# 900147, was not legibly marked. d) Building #7 - The control lever for the Nissan 30 forklift M# CPH01A15V S# 921092, 2 levers worn out, was not legibly marked. e) Building #12 - The control lever for the Nissan 30 forklift M#KCPH01A15FV S#P900417, 2 levers worn out, was not legibly marked. f) Building #13 - The control lever for the Hyundai forklift M#25L-7A S#HHKHHF08LH0003614, 2 levers worn out, was not legibly marked.
Recent events (2)
- — I (O) $0
- — Z (O) $0
1910.303 B01
- Issued
- Mar 10, 2025
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.303(b)(1): Electrical equipment was not free from recognized hazards that were likely to cause death or serious physical harm to employees: Employees engaged in making pesticide products activities in building 1 were exposed to burns, electrical shock hazards in that the Central Machinery Industrial Fan showed no strain relief.
Recent events (2)
- — I (O) $0
- — Z (O) $0
More inspections at Pbi-Gordon Corporation
View Pbi-Gordon Corporation's full OSHA safety record →
More inspections in this industry (NAICS 325320)
More inspections in KS
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 348015579.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.