ATLANTA, GA —
OSHA Inspection: VIKING FABRICATION SERVICES LLC
Referral inspection · Health discipline
At a glance
On , OSHA opened a referral health inspection of VIKING FABRICATION SERVICES LLC in 100 PIEDMONT COURT NW, ATLANTA, GA 30340 (NAICS 332996). OSHA activity number 348021304.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- VIKING FABRICATION SERVICES LLC
- Site address
- 100 PIEDMONT COURT NW
- City
- ATLANTA
- State
- GA
- ZIP
- 30340
- Mailing
- 100 PIEDMONT COURT NW, ATLANTA, GA 30340
What kind of inspection was it?
- Inspection type
- Referral (C)
- Scope
- Partial (B)
- Discipline
- Health
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 332996
- Employees
- 50
- Ownership type
- A
Citations
2 citations on file for this inspection.
1910.95 D01
- Issued
- Jun 26, 2025
- Penalty
- Initial $0 · Current $0
81108111
General-duty citation text
29 CFR 1910.95(d)(1): When information indicated that any employee's exposure equaled or exceed the 8-hour time-weighted average of 85 decibels, the employer did not develop and implement a monitoring program: a) Fabrication area - On or about 02/05/2025, an employees was exposed to continuous noise levels at 54.7% of the permissible daily noise exposure (8-hour Time Weighted Average sound level of 90 dBA) during 391 minutes sampling period on 2/5/2025; exposure calculations included a zero increment for the 89 minutes not sampled. The employer did not implement or develop a monitoring program for employees exposed to potential hearing loss while performing pipe bundling task.
Recent events (1)
- — Z (O) $0
1910.95 G01
- Issued
- Jun 26, 2025
- Penalty
- Initial $0 · Current $0
81108111
General-duty citation text
29 CFR 1910.95(g)(1): The employer did not establish and maintain an audiometric testing program as provided by 29 CFR 1910.95(g) by making audiometric testing available to all employees whose exposures equal or exceed an 8-hour time-weighted average of 85 decibels: a) Fabrication area - On or about 02/05/2025, an employees was exposed to continuous noise levels at 54.7% of the permissible daily noise exposure (8-hour Time Weighted Average sound level of 90 dBA) during 391 minutes sampling period on 2/5/2025; exposure calculations included a zero increment for the 89 minutes not sampled. The employer did not establish and maintain an audiometric testing program available to all employees exposed to potential hearing loss while performing pipe bundling task.
Recent events (1)
- — Z (O) $0
More inspections at Viking Fabrication Services LLC
View Viking Fabrication Services LLC's full OSHA safety record →
More inspections in this industry (NAICS 332996)
More inspections in GA
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 348021304.