Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: JUAN CORDONA

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of JUAN CORDONA in 4141 LINGLESTOWN ROAD, HARRISBURG, PA 17112 (NAICS 238160). OSHA activity number 348028689.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Juan Cordona — free Get an email when a new federal OSHA severe-injury report for Juan Cordona is published. One employer, no account, unsubscribe in one click.
Establishment
JUAN CORDONA
Site address
4141 LINGLESTOWN ROAD
City
HARRISBURG
State
PA
ZIP
17112
Mailing
115 NICHOL AVE., NEW BRUNSWICK, NJ 08901
Inspection type
Planned (H)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Last modified
Data loaded
NAICS code
238160
Employees
3
Ownership type
A

2 citations on file for this inspection.

1926.760 D01

Serious Gravity 5 1 instance 1 exposed
Issued
Apr 29, 2025
Penalty
Initial $7,282 · Current $7,282
29 CFR  1926.760(d)(1): Personal fall arrest system components did not conform to the criteria in 1926.502 (Appendix G to this subpart):  a) 4144 Linglestown Road, Harrisburg, PA, Worksite, Roof - on or about February 4, 2025, employees performing metal roofing installation, approximately 16 feet above grade, were utilizing a combination of shock absorbing lanyards and vertical life lines which created a potential free fall in excess of six feet in the event of a fall.     b) 4144 Linglestown Road, Harrisburg, PA, Worksite, Roof - on or about February 4, 2025, employees performing metal roofing installation, approximately 16 feet above grade, were utilizing a personal fall arrest harness with significant wear that had not been removed from service due to the employee failing to perform a daily inspection on the personal fall arrest system components.
Recent events (1)
  • — Z (S) $7282

1926.760 A01

Willful Gravity 5 1 instance 2 exposed
Issued
Apr 29, 2025
Penalty
Initial $109,236 · Current $109,236
29 CFR  1926.760(a)(1): Each employee engaged in a steel erection activity who is on a walking/working surface with an unprotected side or edge more than 15 feet (4.6 m) above a lower level was not protected from fall hazards by guardrail systems, safety net systems, personal fall arrest systems, positioning device systems, or fall restraint systems.   a) 4144 Linglestown Road, Harrisburg, PA, Worksite, Roof - on or about February 4, 2025 - employees were performing the installation of metal roofing components onto existing structural steel, approximately 16 feet above a lower level, without utilizing personal fall arrest equipment at all times.
Recent events (1)
  • — Z (W) $109236

View Juan Cordona's full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 348028689.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.