ALBANY, NY ·
OSHA Inspection: STILSING ELECTRIC, INC.
Referral inspection · Safety discipline
At a glance
On , OSHA opened a referral safety inspection of STILSING ELECTRIC, INC. in 744 WESTERN AVE., ALBANY, NY 12203 (NAICS 811211). OSHA activity number 348048240.
OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- STILSING ELECTRIC, INC.
- Site address
- 744 WESTERN AVE.
- City
- ALBANY
- State
- NY
- ZIP
- 12203
- Mailing
- PO BOX 27, RENSSELAER, NY 12144
What kind of inspection was it?
- Inspection type
- Referral (C)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- Union (A)
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 811211
- Employees
- 50
- Ownership type
- Private (A)
Citations
2 citations on file for this inspection.
1910.67 C02 V
- Issued
- Mar 14, 2025
- Penalty
- Initial $8,276 · Current $5,379 Reduced
General-duty citation text
29 CFR 1910.67(c)(2)(v): A personal fall arrest or travel restraint system that meets the requirements in 29 CFR part 1910, subpart I, was not worn and attached to the boom or basket when working from an aerial lift. a) Worksite: On or about February 18, 2025, an employee was in a bucket truck installing traffic cameras approximately 14 feet above the ground and was not wearing fall protection.
Recent events (2)
- · I (S) $5379.4
- · Z (S) $8276
1910.135 A01
- Issued
- Mar 14, 2025
- Penalty
- Initial $6,620 · Current $4,303 Reduced
General-duty citation text
29 CFR 1910.135(a)(1): The employer did not ensure that each affected employee wear a protective helmet when working in areas where there is a potential for injury to the head from falling objects: Worksite: On or about February 18, 2025, an employee was standing directly under an aerial lift as the operator was lifting a traffic camera into place. The employee did not have head protection.
Recent events (2)
- · I (O) $4303
- · Z (S) $6620
More inspections at Stilsing Electric, INC.
View Stilsing Electric, INC.'s full OSHA safety record →
More inspections in this industry (NAICS 811211)
More inspections in NY
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). OSHA publishes its own view of this case as inspection number 348048240.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.