Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: RAPID PALLET INC

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of RAPID PALLET INC in 100 CHESTNUT DRIVE, JERMYN, PA 18433 (NAICS 321920). OSHA activity number 348060989.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Rapid Pallet INC — free Get an email when a new federal OSHA severe-injury report for Rapid Pallet INC is published. One employer, no account, unsubscribe in one click.
Establishment
RAPID PALLET INC
Site address
100 CHESTNUT DRIVE
City
JERMYN
State
PA
ZIP
18433
Mailing
100 CHESTNUT DRIVE, JERMYN, PA 18433
Inspection type
Planned (H)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
321920
Employees
60
Ownership type
A

4 citations on file for this inspection.

1910.36 G02

Serious Gravity 5 1 instance 3 exposed
Issued
Mar 5, 2025
Abate by
Apr 7, 2025
Penalty
Initial $6,620 · Current $5,300 Reduced
29 CFR 1910.36(g)(2): Exit access(es) were not at least 28 inches (71.1 cm) wide at all points:  a) Mulch Building: On or about February 25, 2025, employees were exposed to fire hazards due to an emergency exit route that was reduced to under 23 inches wide due to the placement of permanently installed machinery.   Abatement certification required.
Recent events (2)
  • — I (S) $5300
  • — Z (S) $6620

1910.102 A

Serious Gravity 5 1 instance 5 exposed
Issued
Mar 5, 2025
Penalty
Initial $5,627 · Current $4,500 Reduced
29 CFR 1910.102(a): The employer did not ensure that the in-plant transfer, handling, storage, and use of acetylene in cylinders complied with the provisions of CGA Pamphlet G-1-2009 ("Acetylene"), which is incorporated by reference as specified in 29 CFR 1910.6:  a) Maintenance Garage: On or about February 25, 2025, employees were exposed to fire hazards due to acetylene and oxygen cylinders being stored less than 20 feet from each other without a noncombustible, fire-rated partition.  b) Maintenance Garage: On or about February 25, 2025, employees were exposed to fire hazards due to acetylene being stored unsecured from falling over.  c) Maintenance Garage: On or about February 25, 2025, employees were exposed to fire hazards due to acetylene being stored without conspicuous signage posted in the storage area forbidding smoking or the carry of an open flame.  Corrected during inspection.
Recent events (2)
  • — I (S) $4500
  • — Z (S) $5627

1910.253 B04 I

Serious Gravity 5 1 instance 5 exposed
Issued
Mar 5, 2025
Penalty
Initial $0 · Current $0
29 CFR 1910.253(b)(4)(i): Oxygen cylinders were stored near highly combustible material, especially oil and grease; or near reserve stocks of carbide and acetylene or other fuel-gas cylinders, or near other substance likely to cause or accelerate fire:  a) Maintenance Garage: On or about February 25, 2025, employees were exposed to fire hazards due to oxygen cylinders and acetylene cylinders being stored less than 20 feet from each other without a non-combustible fire-resistant barrier between them.  Corrected during inspection.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.303 G01 I

Serious Gravity 1 3 instances 60 exposed
Issued
Mar 5, 2025
Abate by
Apr 11, 2025
Penalty
Initial $4,965 · Current $3,970 Reduced
29 CFR 1910.303(g)(1)(i): The working space in the direction of access to energized equipment operating at 600 volts or less did not comply with the dimensions of this subpart for examination, adjustment, servicing, or maintenance   a) Maintenance Garage: On or about February 25, 2025, employees were exposed to electrical hazards due to 480-volt electrical panels being blocked from access by a tire changing machine.  b) Mulch Building: On or about February 25, 2025, employees were exposed to electrical hazards due to 480-volt electrical panels being blocked from access by machinery.  c) Mulch Building: On or about February 25, 2025, employees were exposed to electrical hazards due to 480-volt electrical panels being blocked from access by a pallet of material.  Abatement certification required.
Recent events (2)
  • — I (S) $3970
  • — Z (S) $4965

View Rapid Pallet INC's full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 348060989.