Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: RYAN METAL PRODUCTS INC. DBA STOR-LOC

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of RYAN METAL PRODUCTS INC. DBA STOR-LOC in 880 N. WASHINGTON AVENUE, KANKAKEE, IL 60901 (NAICS 332322). OSHA activity number 348090135.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Ryan Metal Products INC. DBA Stor-Loc — free Get an email when a new federal OSHA severe-injury report for Ryan Metal Products INC. DBA Stor-Loc is published. One employer, no account, unsubscribe in one click.
Site address
880 N. WASHINGTON AVENUE
City
KANKAKEE
State
IL
ZIP
60901
Mailing
880 N. WASHINGTON AVENUE, KANKAKEE, IL 60901
Inspection type
Planned (H)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
332322
Employees
65
Ownership type
A

2 citations on file for this inspection.

1910.147 C04 I

Serious Gravity 5 1 instance 5 exposed
Issued
Apr 9, 2025
Abate by
May 9, 2025
Penalty
Initial $6,620 · Current $3,500 Reduced
29 CFR 1910.147(c)(4)(i):  Procedures were not developed, documented and utilized for the control of potentially hazardous energy when employees were engaged in activities covered by this section:  a.  On or about March 7, 2025, at the above-mentioned workplace, the written energy control program did not include specific step-by-step procedures to control and lockout energy sources for employees who may perform service and/or maintenance on all multi-source energy equipment such as, but not limited to, press brakes, presses, turret punch presses, and air compressors.  Employees were thereby exposed to the hazards associated with unexpected energization of equipment.
Recent events (2)
  • — I (S) $3500
  • — Z (S) $6620

1910.147 F03 II D

Serious Gravity 10 1 instance 5 exposed
Issued
Apr 9, 2025
Abate by
May 9, 2025
Penalty
Initial $0 · Current $0
29 CFR 1910.147(f)(3)(ii)(D):   Each authorized employee shall affix a personal lockout or tagout device to the group lockout device prior to working on the machine or equipment.  a.  On or about March 7, 2025, at the above-mentioned workplace, personal lockout or tagout devices were not attached to a group lockout device when employees perform service and/or maintenance, to include preventative maintenance, on all multi-source equipment, such as, but not limited to press brakes, presses, turret punch presses, and air compressors.   Employees were thereby exposed to hazards of unexpected  re-energization of equipment.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

View Ryan Metal Products INC. DBA Stor-Loc's full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 348090135.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.