NEW MEADOWS, ID —
OSHA Inspection: TAMARACK MILL, LLC
Complaint inspection · Safety discipline
At a glance
On , OSHA opened a complaint safety inspection of TAMARACK MILL, LLC in 3555 HWY 95, NEW MEADOWS, ID 83654 (NAICS 321113). OSHA activity number 348103409.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- TAMARACK MILL, LLC
- Site address
- 3555 HWY 95
- City
- NEW MEADOWS
- State
- ID
- ZIP
- 83654
- Mailing
- P.O. DRAWER H, NEW MEADOWS, ID 83654
What kind of inspection was it?
- Inspection type
- Complaint (B)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Last modified
- Data loaded
Establishment context
- NAICS code
- 321113
- Employees
- 11
- Ownership type
- A
Citations
12 citations on file for this inspection.
1910.147 C04 I
- Issued
- Jul 1, 2025
- Abate by
- Aug 14, 2025
- Penalty
- Initial $12,744 · Current $10,830 Reduced
General-duty citation text
29 CFR 1910.147(c)(4)(i): Procedures were not developed, documented and utilized for the control of potentially hazardous energy when employees were engaged in activities covered by this section: (a) On March 07, 2025, procedures were not utilized by an employee when cleaning the saw box of the Schurman Machine Incorporated Edger Saw, Model No. 6TA60, Serial No. 2512.
Recent events (3)
- — I (S) $10830
- — P (S) $10830
- — Z (S) $12744
1910.147 D04 I
- Issued
- Jul 1, 2025
- Abate by
- Aug 14, 2025
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.147(d)(4)(i): Lockout or tagout devices were not affixed to each energy isolating device by authorized employees: (a) On March 07, 2025, an employee was exposed to an unexpected release of energy when cleaning out the saw box of the Schurman Machine Incorporated Edger Saw Model No. 6TA60 Serial No. 2512.
Recent events (3)
- — I (S) $0
- — P (S) $0
- — Z (S) $0
1910.147 C04 II
- Issued
- Jul 1, 2025
- Abate by
- Aug 14, 2025
- Penalty
- Initial $12,744 · Current $10,830 Reduced
General-duty citation text
29 CFR 1910.147(c)(4)(ii): Procedures did not clearly and specifically outline the scope, purpose, authorization, rules, and techniques to be utilized for the control of hazardous energy, and the means to enforce compliance including, but not limited to, 29 CFR 1910.147(c)(4)(ii)(A), (c)(4)(ii)(B), (c)(4)(ii)(C) and (c)(4)(ii)(D): (a) On and prior to March 10, 2025, employees were exposed to an unexpected release of energy while cleaning the saw box of the Schurman Machine Incorporated Edger Saw Model No. 6TA60 Serial No. 2512 in that the specific procedure did not include information on how to isolate the hydraulic energy. (b) On and prior to March 10, 2025, employees were exposed to an unexpected release of energy while cleaning the saw box of the Schurman Machine Incorporated Edger Saw Model No. 6TA60 Serial No. 2512 in that the specific procedure did not clearly identify the type of energy isolating device to be used on the control power of the operator's console. (c) On and prior to March 10, 2025, employees were exposed to an unexpected release of energy while cleaning the saw box of the Schurman Machine Incorporated Edger Saw Model No. 6TA60 Serial No. 2512 in that the specific procedure did not include locking out the "buckets" for the scan and infeed chains.
Recent events (3)
- — I (S) $10830
- — P (S) $10830
- — Z (S) $12744
1910.147 C05 I
- Issued
- Jul 1, 2025
- Abate by
- Jul 28, 2025
- Penalty
- Initial $12,744 · Current $10,830 Reduced
General-duty citation text
29 CFR 1910.147(c)(5)(i): Locks, tags, chains, wedges, key blocks, adapter pins, self-locking fasteners, or other hardware were not provided by the employer for isolating, securing or blocking of machines or equipment from energy sources: (a) On March 7, 2025, an employee cleaning the saw box of the Schurman Machine Incorporated Edger Saw, Model No. 6TA60, Serial No. 2512 was not provided a lock out device to isolate equipment from energy sources.
Recent events (2)
- — I (S) $10830
- — Z (S) $12744
1910.147 C06 I
- Issued
- Jul 1, 2025
- Abate by
- Aug 14, 2025
- Penalty
- Initial $12,744 · Current $10,830 Reduced
General-duty citation text
29 CFR 1910.147(c)(6)(i): The employer did not conduct an annual or more frequent inspection of the energy control procedure to ensure that the procedure and requirements of this standard were followed: (a) On March 10, 2025, and at times prior thereto, employees performed maintenance and servicing activities on the Schurman Machine Incorporated Edger Saw Model No. 6TA60 Serial No. 2512.
Recent events (3)
- — I (S) $10830
- — P (S) $10830
- — Z (S) $12744
1910.147 C07 I
- Issued
- Jul 1, 2025
- Abate by
- Aug 14, 2025
- Penalty
- Initial $12,744 · Current $10,830 Reduced
General-duty citation text
29 CFR 1910.147(c)(7)(i): The employer did not provide adequate training to ensure that employees acquired the knowledge and skills required for the safe application, usage and removal of energy control devices: (a) On March 10, 2025, and at times prior thereto, employees performed maintenance and servicing activities, including cleaning the saw box on the Schurman Machine Incorporated Edger Saw Model No. 6TA60 Serial No. 2512.
Recent events (3)
- — I (S) $10830
- — P (S) $10830
- — Z (S) $12744
1910.303 E
- Issued
- Jul 1, 2025
- Abate by
- Jul 28, 2025
- Penalty
- Initial $5,462 · Current $0 Reduced
General-duty citation text
29 CFR 1910.303(e): Markings were not provided on electrical equipment giving voltage, current, wattage, and other ratings as necessary: (a) On March 07, 2025, and at times prior thereto, the plant manager and maintenance employees were exposed to 110 volts of electricity when replacing a fuse in the Pony Panel. (b) On March 07, 2025, and at times prior thereto, employees performing servicing or maintenance on the Schurman Machine Incorporated Edger Saw Model No. 6TA60, Serial No. 2512 disconnect electrical energy at various electrical panels (buckets) including the Pony Panel.
Recent events (2)
- — I (S) $0
- — Z (S) $5462
1910.335 B01
- Issued
- Jul 1, 2025
- Abate by
- Jul 28, 2025
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.335(b)(1): Safety signs, safety symbols, or accident prevention tags were not used where necessary to warn employees about electrical hazards which may endanger them: (a) On March 07, 2025, and at times prior thereto, the plant manager was exposed to 110 volts of electricity when replacing a fuse in the Pony Panel. (b) On March 07, 2025, and at times prior thereto, employees performing servicing or maintenance on the Schurman Machine Incorporated Edger Saw Model No. 6TA60, Serial No. 2512 disconnect electrical energy at various electrical panels (buckets) including the Pony Panel.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.332 B02
- Issued
- Jul 1, 2025
- Abate by
- Jul 28, 2025
- Penalty
- Initial $9,104 · Current $0 Reduced
General-duty citation text
29 CFR 1910.332(b)(2): Employees, who were not qualified persons, were not trained in and familiar with any electrically related safety practices not specifically addressed by 29 CFR 1910.331 through 29 CFR 1910.335, but which were necessary for their safety: (a) On March 07, 2025, and at times prior thereto, the plant manager was exposed to 110 volts of electricity when replacing a fuse in the Pony Panel. (b) On March 07, 2025, and at times prior thereto, employees performing servicing or maintenance on the Schurman Machine Incorporated Edger Saw Model No. 6TA60, Serial No. 2512 disconnected electrical energy at various electrical panels (buckets) including the Pony Panel.
Recent events (2)
- — I (S) $0
- — Z (S) $9104
1910.333 A01
- Issued
- Jul 1, 2025
- Abate by
- Jul 28, 2025
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.333(a)(1): Live parts to which an employee may be exposed were not deenergized before the employee worked on or was near to them: (a) On March 07, 2025, the plant manager was exposed to 110 volts of electricity when replacing fuses in the Pony Panel.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.333 B02 III A
- Issued
- Jul 1, 2025
- Abate by
- Aug 14, 2025
- Penalty
- Initial $0 · Current $4,550
General-duty citation text
29 CFR 1910.333(b)(2)(iii)(A): A lock and a tag were not placed on each disconnecting means used to deenergize circuits and equipment on which work was to be performed: (b) On March 07, 2025, an employee was exposed to 110 volts of electricity when repairing the control cord to the Schurman Machine Incorporated Edger Saw Model No. 6TA60 Serial No. 2512.
Recent events (3)
- — I (S) $4550
- — P (S) $4550
- — Z (S) $0
1910.333 C02
- Issued
- Jul 1, 2025
- Abate by
- Jul 28, 2025
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.333(c)(2): The employer did not ensure that only qualified persons were working on energized circuits and that qualified persons were familiar with the proper use of special precautionary techniques, personal protective equipment, insulating and shielding materials, and insulated tools (a) On March 07, 2025, the plant manager was exposed to 110 volts of electricity when replacing a fuse in the Pony Panel.
Recent events (2)
- — I (S) $0
- — Z (S) $0
More inspections at Tamarack Mill, LLC
View Tamarack Mill, LLC's full OSHA safety record →
More inspections in this industry (NAICS 321113)
More inspections in ID
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 348103409.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.