BELOIT, WI —
OSHA Inspection: SPRAY-TEK, LLC
Complaint inspection · Safety discipline
At a glance
On , OSHA opened a complaint safety inspection of SPRAY-TEK, LLC in 3355 EAST COLLEY ROAD, BELOIT, WI 53511 (NAICS 325998). OSHA activity number 348107822.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- SPRAY-TEK, LLC
- Site address
- 3355 EAST COLLEY ROAD
- City
- BELOIT
- State
- WI
- ZIP
- 53511
- Mailing
- 3355 EAST COLLEY ROAD, BELOIT, WI 53511
What kind of inspection was it?
- Inspection type
- Complaint (B)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 325998
- Employees
- 56
- Ownership type
- A
Citations
7 citations on file for this inspection.
1910.28 B02 I
- Issued
- Jul 25, 2025
- Abate by
- Dec 31, 2025
- Penalty
- Initial $16,550 · Current $10,550 Reduced
General-duty citation text
29 CFR 1910.28(b)(2)(i): The employer did not ensure that each employee in a hoist area is protected from falling 4 feet (1.2 m) or more to a lower level by one of the systems listed in 29 CFR 1910.28(b)(2)(i)(A)-(C). On or about February 13, 2025, in phase 2 mixing rooms the employer failed to ensure that when batchers removed guardrail sections to facilitate mixer loading activities were protected from a fall greater than 4ft. Batchers were exposed to a fall onto a hard surface while they facilitated mixer loading activities.
Recent events (2)
- — I (S) $10550
- — Z (S) $16550
1910.134 C02 I
- Issued
- Jul 25, 2025
- Abate by
- Sep 2, 2025
- Penalty
- Initial $7,660 · Current $4,883 Reduced
General-duty citation text
29 CFR 1910.134(c)(2)(i): Respirator users were not provided with the information contained in Appendix D to 29 CFR 1910.134 when the employer determined that any voluntary respirator use was permissible: On or about and times prior to March 24, 2025, the employer failed to provide voluntary users of KN95 filtering facepiece respirators with the information contained in Appendix D to 29 CFR 1910.134. Voluntary users of KN95 filtering facepiece respirators were unaware of the respirator's limitations when exposed to nuisance dust in dryer rooms.
Recent events (2)
- — I (S) $4883
- — Z (S) $7660
1910.147 C04 I
- Issued
- Jul 25, 2025
- Abate by
- Sep 2, 2025
- Penalty
- Initial $15,322 · Current $9,768 Reduced
General-duty citation text
29 CFR 1910.147(c)(4)(i): Procedures were not developed, documented and utilized for the control of potentially hazardous energy when employees were engaged in activities covered by this section: On or about March 13, 2025, in the mixing rooms, hazardous energy control procedures were not developed when operators or batchers engaged in covered maintenance and servicing activities on the Sani Matic filter(s). Maintenance and servicing performed included but were not limited to setup, cleaning and replacement of filters. Employees were exposed to struck-by hazards from residual energy left inside the filter line.
Recent events (2)
- — I (S) $9768
- — Z (S) $15322
1910.147 C04 II
- Issued
- Jul 25, 2025
- Abate by
- Sep 2, 2025
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.147(c)(4)(ii): Procedures did not clearly and specifically outline the scope, purpose, authorization, rules, and techniques to be utilized for the control of hazardous energy, and the means to enforce compliance including, but not limited to, 29 CFR 1910.147(c)(4)(ii)(A), (c)(4)(ii)(B), (c)(4)(ii)(C) and (c)(4)(ii)(D): On or about and times prior to March 24, 2025, the employer did not ensure that the energy control procedure addressed all potentially hazardous energy sources for employees who perform servicing operations on equipment such as, but not limited to, the Phase 2 Homogenizer. Servicing operations included, equipment tear down and sanitation. Noted deficiencies included, but may not be limited to, the following: (1) Specific procedural steps for shutting down, isolating, blocking and securing machines or equipment to control hazardous energy pursuant to 1910.147(c)(4)(ii)(B). The procedure did not specifically address controlling the Homogenizer's pneumatic energy source prior to performing service and maintenance activities on equipment.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.151 C
- Issued
- Jul 25, 2025
- Abate by
- Sep 2, 2025
- Penalty
- Initial $7,660 · Current $4,883 Reduced
General-duty citation text
29 CFR 1910.151(c): Where employees were exposed to injurious corrosive materials, suitable facilities for quick drenching or flushing of the eyes and body were not provided within the work area for immediate emergency use: On or before March 13, 2025, in Phase 2 Nano room employees who manually handled corrosive materials such as but not limited to Lactic Acid, MPA No. 168, Ultra 1030, and Hydrisoak No. 180 for Clean-In-Place (CIP) operations were not provided with suitable facilities (i.e., eyewash and shower) within the work area for immediate emergency use.
Recent events (2)
- — I (S) $4883
- — Z (S) $7660
1910.147 C07 IV
- Issued
- Jul 25, 2025
- Abate by
- Sep 2, 2025
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.147(c)(7)(iv): The employer did not certify that employee training had been accomplished and kept up to date: On or about March 13, 2025, the employer failed to certify authorized personnel lockout tagout training for employees engaged in covered maintenance and servicing (i.e., teardown, sanitation) activities on the Sani Matic filter(s).
Recent events (2)
- — I (O) $0
- — Z (O) $0
1910.178 G02
- Issued
- Jul 25, 2025
- Abate by
- Sep 2, 2025
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.178(g)(2): Battery charging apparatus for industrial trucks located in battery changing and charging installation was not protected from damage by trucks: On or about March 13, 2025, by the shipping & receiving office located in the warehouse, EnerSys battery charging apparatuses for industrial trucks were not protected from damage.
Recent events (2)
- — I (O) $0
- — Z (O) $0
More inspections at Spray-Tek, LLC
View Spray-Tek, LLC's full OSHA safety record →
More inspections in this industry (NAICS 325998)
More inspections in WI
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 348107822.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.