Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: MAGNATROL VALVE CORPORATION

Planned inspection · Health discipline

On , OSHA opened a planned health inspection of MAGNATROL VALVE CORPORATION in 67 5TH AVENUE, HAWTHORNE, NJ 07506 (NAICS 332911). OSHA activity number 348122227.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Magnatrol Valve Corporation — free Get an email when a new federal OSHA severe-injury report for Magnatrol Valve Corporation is published. One employer, no account, unsubscribe in one click.
Site address
67 5TH AVENUE
City
HAWTHORNE
State
NJ
ZIP
07506
Mailing
P.O. BOX 17, HAWTHORNE, NJ 07506
Inspection type
Planned (H)
Scope
Complete (A)
Discipline
Health
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
332911
Employees
32
Ownership type
A

7 citations on file for this inspection.

1910.157 C01

Serious Gravity 1 1 instance 1 exposed
Issued
Jun 26, 2025
Penalty
Initial $5,462 · Current $3,823 Reduced
29 CFR 1910.157(c)(1): Portable fire extinguishers were not mounted, located and identified so that they were readily accessible without subjecting the employees to injuries:  a) Production area: A portable fire extinguisher was blocked by drums with metal scrap, on or about 03/20/25.
Recent events (2)
  • — I (S) $3823.4
  • — Z (S) $5462

1910.157 G01

Serious Gravity 1 1 instance 5 exposed
Issued
Jun 26, 2025
Penalty
Initial $0 · Current $0
29 CFR 1910.157(g)(1): An educational program was not provided for all employees to familiarize them with the general principles of fire extinguisher use and the hazards involved with incipient stage fire fighting:   a) Facility: Portable fire extinguisher training was not provided for the employees who were expected to use the fire extinguishers during a fire emergency, on or about 3/20/2025.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.157 G02

Serious Gravity 1 1 instance 4 exposed
Issued
Jun 26, 2025
Penalty
Initial $0 · Current $0
29 CFR 1910.157(g)(2): The educational program to familiarize employees with the general principles of fire extinguisher use and the hazards involved with incipient stage firefighting was not provided to all employees upon initial employment, and at least annually thereafter:   a) Facility: Portable fire extinguisher training was not provided for the employees at least annually when all employees were expected to use the fire extinguishers during a fire emergency, on or about 3/20/2025.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.215 A04

Serious Gravity 5 2 instances 2 exposed
Issued
Jun 26, 2025
Penalty
Initial $7,282 · Current $5,097 Reduced
29 CFR  1910.215(a)(4): Grinding machinery was not used with work rest(s) to support offhand grinding work or was not adjusted closely to the wheel with a maximum opening of one eighth inch:  a) Production Area: The distances between the work rests and abrasive wheel of a Craftsman Commercial bench grinder exceeded one eighth inch, this distance was about three eighths (3/8) inch, on or about 03/20/25.  b) Production area: General Electric pedestal grinder was used without work rests to support offhand grinding work, on or about 3/20/25
Recent events (2)
  • — I (S) $5097.4
  • — Z (S) $7282

1910.215 B09

Serious Gravity 1 1 instance 1 exposed
Issued
Jun 26, 2025
Penalty
Initial $0 · Current $0
29 CFR 1910.215(b)(9): The distance between the abrasive wheel periphery(s) and the adjustable tongue or the end of the safety guard peripheral member at the top exceeded one fourth inch:  a) Production area: The distances between the adjustable tongue and the abrasive wheel periphery of a Craftsman Commercial bench grinder exceeded one fourth inch, this distance was about a half inch, on or about 03/20/25.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.212 B

Serious Gravity 1 1 instance 1 exposed
Issued
Jun 26, 2025
Abate by
Jul 23, 2025
Penalty
Initial $5,462 · Current $3,823 Reduced
29 CFR 1910.212(b): Machine(s) designed for fixed location(s) were not securely anchored to prevent walking or moving:  a) Production area: General Electric pedestal grinder was not anchored to prevent moving, on or about 3/20/25
Recent events (2)
  • — I (S) $3823.4
  • — Z (S) $5462

1910.1200 E01

Other-than-serious 1 instance 4 exposed
Issued
Jun 26, 2025
Abate by
Jul 23, 2025
Penalty
Initial $0 · Current $0
29 CFR 1910.1200(e)(1): Employer had not developed or implemented a written hazard communication program which included the requirements outlined in 29 CFR 1910.1200(e)(1)(i) and (e)(1)(ii):  a) Facility: A written hazard communication program was not maintained at the workplace where employees worked with hazardous chemicals including, but not limited to, Tech Cool 35037,  ECOCOOL 7830, and  Medallion Plus AW ISO 32 Hydraulic Oils, on or about 03/20/2025.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

View Magnatrol Valve Corporation's full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 348122227.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.