Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: ARCOS INDUSTRIES, LLC

Referral inspection · Safety discipline

On , OSHA opened a referral safety inspection of ARCOS INDUSTRIES, LLC in 394 ARCOS DRIVE, MOUNT CARMEL, PA 17851 (NAICS 333992). OSHA activity number 348126475.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Arcos Industries, LLC — free Get an email when a new federal OSHA severe-injury report for Arcos Industries, LLC is published. One employer, no account, unsubscribe in one click.
Site address
394 ARCOS DRIVE
City
MOUNT CARMEL
State
PA
ZIP
17851
Mailing
394 ARCOS DRIVE, MOUNT CARMEL, PA 17851
Inspection type
Referral (C)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
A
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
333992
Employees
70
Ownership type
A

2 citations on file for this inspection.

1910.147 C04 I

Serious Gravity 5 1 instance 1 exposed
Issued
May 2, 2025
Penalty
Initial $7,035 · Current $5,035 Reduced
29 CFR  1910.147(c)(4)(i): Procedures were not developed, documented and utilized for the control of potentially hazardous energy when employees were engaged in activities covered by this section:  a) Electro Cut Crane, Production Area, Lower Building - On or about April 2, 2025, an employee was exposed to an electrical hazard while troubleshooting an underhung hoist because they were permitted to service the system without utilizing the procedure for controlling hazardous energy.  Certification Not Required.
Recent events (2)
  • — I (S) $5035
  • — Z (S) $7035

1910.147 C06 II

Other-than-serious 1 instance 5 exposed
Issued
May 2, 2025
Abate by
May 21, 2025
Penalty
Initial $0 · Current $0
29 CFR  1910.147(c)(6)(ii): The employer did not certify that periodic inspections of the energy control procedures had been performed:  a) Facility Wide  -  On or about March 21, 2025, the employer failed to verify via a written certification that the energy control procedures had been inspected at least annually.   Abatement Certification Required.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

View Arcos Industries, LLC's full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 348126475.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.