Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: MY 6 CONSTRUCTION LLC

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of MY 6 CONSTRUCTION LLC in 4655 HEMINGWAY TRAIL, CUMMING, GA 30041 (NAICS 238120). OSHA activity number 348141524.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch MY 6 Construction LLC — free Get an email when a new federal OSHA severe-injury report for MY 6 Construction LLC is published. One employer, no account, unsubscribe in one click.
Site address
4655 HEMINGWAY TRAIL
City
CUMMING
State
GA
ZIP
30041
Mailing
10534 HIGHWAY 225 S., CHATSWORTH, GA 30705
Inspection type
Planned (H)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Last modified
Data loaded
NAICS code
238120
Employees
6
Ownership type
A

4 citations on file for this inspection.

1926.95 A

Serious Gravity 1 1 instance 5 exposed
Issued
Jun 12, 2025
Penalty
Initial $4,965 · Current $4,965
29 CFR 1926.95(a): Personal protective equipment (PPE), including protection for the eyes, face, head, and extremities, was not provided, used, or maintained in a sanitary and reliable condition where necessary due to hazards of processes or environment, chemical hazards, radiological hazards, or mechanical irritants capable of causing injury or impairment:  a) At a new commercial construction site located at 4655 Hemingway Trail, Cumming, GA 30041; Roof: On or about 03/25/2025, the employer exposed employees to potential chemical irritation or burns, in that appropriate eye, face, and extremity protection was not used while handling G524+ Simple Saver High Tack Sealant.
Recent events (1)
  • — Z (S) $4965

1926.760 A01

Serious Gravity 10 1 instance 5 exposed
Issued
Jun 12, 2025
Penalty
Initial $11,585 · Current $11,585
29 CFR 1926.760(a)(1): The employer did not ensure that each employee engaged in steel erection activities on a walking/working surface with an unprotected side or edge more than 15 feet above a lower level was protected from fall hazards by the use of guardrail systems, safety net systems, personal fall arrest systems, positioning device systems, or fall restraint systems:  a) At a new commercial construction site located at 4655 Hemingway Trail, Cumming, GA 30041; Roof: On or about 03/25/2025, the employer exposed employees to fall hazards of approximately 25 feet to the outside of the structure and 23 feet, 3 inches to the inside, in that an appropriate fall protection system was not used while employees performed steel erection work from the roof area.
Recent events (1)
  • — Z (S) $11585

1926.761 B

Serious Gravity 5 1 instance 5 exposed
Issued
Jun 12, 2025
Penalty
Initial $0 · Current $0
29 CFR 1926.761(b): The employer did not ensure that each employee exposed to a fall hazard was trained in accordance with the requirements of this section:  a) New commercial structure located at 4655 Hemingway Trail, Cumming GA 30041; Roof: On or about 03/25/2025, the employer exposed employees to fall hazards of approximately 25 feet to the outside of the structure and 23 feet, 3 inches to the interior, in that a fall protection training program had not been adequately developed, implemented, or maintained for employees exposed to fall hazards.
Recent events (1)
  • — Z (S) $0

1926.59

Other-than-serious 1 instance 5 exposed
Issued
Jun 12, 2025
Penalty
Initial $0 · Current $0
29 CFR 1926.59: The employer did not develop and implement a written hazard communication program in accordance with the requirements of 29 CFR 1910.1200, as incorporated by reference:   a) New commercial structure located at 4655 Hemingway Trail, Cumming, GA 3004; Roof: On or about 03/25/2025, the employer failed to develop, implement, and maintain a written hazard communication program, thereby exposing employees to chemical hazards while using G524+ Simple Saver High Tack Sealant.
Recent events (1)
  • — Z (O) $0

View MY 6 Construction LLC's full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 348141524.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.