Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: ALGUS PACKAGING, INC.

Complaint inspection · Health discipline

On , OSHA opened a complaint health inspection of ALGUS PACKAGING, INC. in 1212 E. TAYLOR ST., DEKALB, IL 60115 (NAICS 326112). OSHA activity number 348182825.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Algus Packaging, INC. — free Get an email when a new federal OSHA severe-injury report for Algus Packaging, INC. is published. One employer, no account, unsubscribe in one click.
Site address
1212 E. TAYLOR ST.
City
DEKALB
State
IL
ZIP
60115
Mailing
1212 E. TAYLOR ST. P.O. BOX 488, DEKALB, IL 60115
Inspection type
Complaint (B)
Scope
Partial (B)
Discipline
Health
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
326112
Employees
70
Ownership type
A

2 citations on file for this inspection.

1910.147 D

Serious Gravity 5 1 instance 1 exposed
Issued
Sep 30, 2025
Abate by
Oct 29, 2025
Penalty
Initial $10,641 · Current $7,449 Reduced
29 CFR  1910.147(d): The established procedure for the application of energy control (the lockout or tagout procedures) was not done in sequence as required by 29 CFR 1910.147(d)(1)-(6):   a) On or about April 15, 2025, the employer did not ensure that employees implemented energy control steps prior to performing servicing and maintenance activities on the #1 thermoforming line.  Hazardous  energy was not isolated prior to employees troubleshooting and setting up the equipment, exposing them to struck-by and caught-between hazards from moving parts in the event of unexpected start-up or movement of the machine.  As a result, the remaining applicable energy control elements, involving machine isolation [1910.147(d)(3)], lockout/tagout device application [1910.147(d)(4)], dissipation of residual energy [1910.147(d)(5)(i)], and verification of isolation [1910.147(d)(6)] were not implemented to protect employees from machine hazards.   b) On or about April 15, 2025, the employer did not ensure that employees implemented energy control steps prior to performing servicing and maintenance activities on the B1 Stacker.  Hazardous energy was not isolated prior to employees troubleshooting and setting up the equipment, exposing them to  struck-by hazard and caught-between hazards from moving parts in the event of unexpected start-up or movement of the machine.   As a result, the remaining applicable energy control elements, involving machine isolation [1910.147(d)(3)], lockout/tagout device application [1910.147(d)(4)], dissipation of residual energy [1910.147(d)(5)(i)], and verification of isolation [1910.147(d)(6)] were not implemented to protect employees from machine hazards.   Abatement documentation is required for this item in accordance with the requirements of 29 CFR 1903.19(d).
Recent events (2)
  • — I (S) $7448.7
  • — Z (S) $10641

1910.212 A01

Serious Gravity 5 2 instances 2 exposed
Issued
Sep 30, 2025
Abate by
Oct 29, 2025
Penalty
Initial $10,641 · Current $7,449 Reduced
29 CFR  1910.212(a)(1): One or more methods of machine guarding was not provided to protect the operator and other employees in the machine area from hazards such as those created by point of operation, ingoing nip points, rotating parts, flying chips and sparks:  a)  On or about April 15, 2025, the employer did not ensure that the forming dies on the thermoforming line #3 were guarded.  The side gate guard was opened while machine was in operation, exposing employees to crushing injuries from moving parts while the machine cycled.  b) On or about April 15, 2025, the employer didn't ensure that the operation station on the stacking area and the end of thermoforming line #3 was guarding to protect employees from crushing injuries from moving parts while the machine cycled.  c)  On or about April 15, 2025, the employer didn't ensure that the operation station on the stacking area and the end of thermoforming line #5 was guarding to protect employees from crushing injuries from moving parts while the machine cycled.  Abatement documentation is required for this item in accordance with the requirements of 29 CFR 1903.19(d).
Recent events (2)
  • — I (S) $7448.7
  • — Z (S) $10641

View Algus Packaging, INC.'s full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 348182825.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.