VINTON, TX —
OSHA Inspection: TEWA LLC
Unprogrammed Related inspection · Safety discipline
At a glance
On , OSHA opened an unprogrammed Related safety inspection of TEWA LLC in 251 VALLEY CHILI RD, VINTON, TX 79821 (NAICS 333243). OSHA activity number 348185315.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- TEWA LLC
- Site address
- 251 VALLEY CHILI RD
- City
- VINTON
- State
- TX
- ZIP
- 79821
- Mailing
- PO BOX 938, CANUTILLO, TX 79835
What kind of inspection was it?
- Inspection type
- Unprogrammed Related (G)
- Scope
- Complete (A)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Last modified
- Data loaded
Establishment context
- NAICS code
- 333243
- Employees
- 57
- Ownership type
- A
Citations
7 citations on file for this inspection.
1910.147 C07 III A
- Issued
- Sep 30, 2025
- Abate by
- Oct 10, 2025
- Penalty
- Initial $10,427 · Current $6,000 Reduced
General-duty citation text
29 CFR 1910.147(c)(7)(iii)(A): Retraining was not provided for authorized and affected employees when there was a change in their job assignments, a change in machines, equipment or processes that presented a new hazard, or when there was a change in the energy control procedures: On or about April 16, 2025, in the byproduct processing area, an employee utilized a screw auger without being retrained as an affected employee after a change in job assignments.
Recent events (2)
- — I (S) $6000
- — Z (S) $10427
1910.212 A01
- Issued
- Sep 30, 2025
- Abate by
- Oct 10, 2025
- Penalty
- Initial $8,938 · Current $5,500 Reduced
General-duty citation text
29 CFR 1910.212(a)(1): One or more methods of machine guarding was not provided to protect the operator and other employees in the machine area from hazards such as those created by point of operation, ingoing nip points, rotating parts, flying chips and sparks: a) On or about April 22, 2025, on the east production floor, employees utilized custom table saws with inadequate guarding while engaged in woodworking activities. b) On or about April 22, 2025, in the maintenance area, employees utilized a chop saw with inadequate guarding while engaged in daily duties.
Recent events (2)
- — I (S) $5500
- — Z (S) $8938
1910.213 N01
- Issued
- Sep 30, 2025
- Abate by
- Oct 10, 2025
- Penalty
- Initial $7,448 · Current $4,500 Reduced
General-duty citation text
29 CFR 1910.213(n)(1): Metal guard(s) covering the cutting head(s), and saw(s) if used, were not provided on: On or about April 22, 2025, on the production floor, employees utilized molding machines without metal guards covering saw blades while engaged in woodworking activities.
Recent events (2)
- — I (S) $4500
- — Z (S) $7448
1910.265 C04 IV
- Issued
- Sep 30, 2025
- Abate by
- Oct 10, 2025
- Penalty
- Initial $10,427 · Current $6,000 Reduced
General-duty citation text
29 CFR 1910.265(c)(4)(iv): Elevated walk(s) and runway(s), 4 feet or more from floor level, were not provided with a standard railing: On or about April 16, 2025, in the byproduct processing area, employees accessed a walking working surface without a standard railing while clearing a jam in a horizontal auger.
Recent events (2)
- — I (S) $6000
- — Z (S) $10427
1910.265 C20 V
- Issued
- Sep 30, 2025
- Abate by
- Oct 10, 2025
- Penalty
- Initial $8,938 · Current $5,500 Reduced
General-duty citation text
29 CFR 1910.265(c)(20)(v): Exhaust pipes discharged into an unconfined outside pile when uncontrolled fire or explosion hazards were created. On or about April 16, 2025, on the east side of the facility, employees utilized woodworking machines whose exhaust pipes discharged into unconfined piles while engaged in daily duties.
Recent events (2)
- — I (S) $5500
- — Z (S) $8938
1910.303 G01 I A
- Issued
- Sep 30, 2025
- Abate by
- Oct 10, 2025
- Penalty
- Initial $4,469 · Current $3,000 Reduced
General-duty citation text
29 CFR 1910.303(g)(1)(i)(A): For electric equipment operating at 600 volts, nominal, or less to ground, and likely to require examination, adjustment, servicing, or maintenance while energized, the depth of the working space in the direction of access to live parts (as measured from the live parts where they were exposed or from the enclosure front or opening where they were enclosed) was less than indicated in Table S-1 of Subpart S of Part 1910: On or about April 22, 2025, on the production floor, employees utilized a molding machine with less than 36 inches of space from the enclosed electrical equipment while engaged in woodworking activities.
Recent events (2)
- — I (S) $3000
- — Z (S) $4469
1910.305 D02
- Issued
- Sep 30, 2025
- Abate by
- Oct 10, 2025
- Penalty
- Initial $7,448 · Current $4,500 Reduced
General-duty citation text
29 CFR 1910.305(d)(2): Panelboards, other than the dead front externally-operable type and accessible only to qualified persons, were not mounted in cabinets, cutout boxes, or enclosures designed for the purpose and/or were not dead front: On or about April 22, 2025, on Molder #2, employees utilized a control panel inside a molder electrical box through a cut out opening while engaged in woodworking activities.
Recent events (2)
- — I (S) $4500
- — Z (S) $7448
More inspections at Tewa LLC
View Tewa LLC's full OSHA safety record →
More inspections in this industry (NAICS 333243)
More inspections in TX
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 348185315.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.