OSHA Inspection: PRO METAL RECYCLING INC.

Complaint inspection · Safety discipline

On , OSHA opened a complaint safety inspection of PRO METAL RECYCLING INC. in 16745 LATHROP AVENUE, HARVEY, IL 60426 (NAICS 423930). OSHA activity number 348201260.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch PRO Metal Recycling INC. — free Get an email when a new federal OSHA severe-injury report for PRO Metal Recycling INC. is published. One employer, no account, unsubscribe in one click.
Site address
16745 LATHROP AVENUE
City
HARVEY
State
IL
ZIP
60426
Mailing
16745 LATHROP AVENUE, HARVEY, IL 60426
Inspection type
Complaint (B)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
423930
Employees
25
Ownership type
A

6 citations on file for this inspection.

1910.27 A

Serious Gravity 5 1 instance 1 exposed
Issued
Jul 30, 2025
Abate by
Aug 25, 2025
Penalty
Initial $12,769 · Current $7,000 Reduced
29 CFR  1910.27(a): The employer did not ensure that scaffolds used in general industry meet the requirements in 29 CFR part 1926, subpart L (Scaffolds).  a) On or about April 24, 2025, at the above addressed jobsite, an employee conducting repairs to a overhead door from a forklift, repairs would be conducted at heights twelve (12) feet above ground was not protected from falling, thereby exposing the employee to fall hazards. The scaffold (i.e., steel wire mesh pallet on the forks of a forklift) did not meet the requirements of 29 CFR part 1926, subpart L.
Recent events (2)
  • — I (S) $7000
  • — Z (S) $12769

1910.110 B06 VII

Serious Gravity 5 1 instance 1 exposed
Issued
Jul 30, 2025
Abate by
Aug 18, 2025
Penalty
Initial $12,769 · Current $7,000 Reduced
29 CFR  1910.110(b)(6)(vii): The separation between liquefied petroleum gas containers and flammable liquid tanks was not 20 feet.  (a) On or about April 24, 2025, the employer failed to keep liquefied petroleum gas containers from diesel fuel stored in an above ground storage unit, thereby exposing employees to hazards associated with fire and explosions.
Recent events (2)
  • — I (S) $7000
  • — Z (S) $12769

1910.178 L04 III

Serious Gravity 1 2 instances 1 exposed
Issued
Jul 30, 2025
Abate by
Sep 16, 2025
Penalty
Initial $7,660 · Current $4,000 Reduced
29 CFR  1910.178(l)(4)(iii): An evaluation of each powered industrial truck operator's performance was not being conducted at least once every three years:  a. On or about April 24, 2025, at the above address, the employer failed to ensure that employee(s) who operate power industrial trucks were reevaluated and certified to perform the tasks in a safe manner at least once every three years.
Recent events (2)
  • — I (S) $4000
  • — Z (S) $7660

1910.253 B02 II

Serious Gravity 5 1 instance 1 exposed
Issued
Jul 30, 2025
Abate by
Aug 11, 2025
Penalty
Initial $12,769 · Current $7,000 Reduced
29 CFR 1910.253(b)(2)(ii): Inside of buildings, cylinders were not stored in a well-protected, well-ventilated, dry location, at least 20 feet (6.1 m) from highly combustible materials such as oil or excelsior:  a) On or about April 24, 2025, the employer did not ensure cylinders containing oxygen and propylene were well protected. Cylinders were not stored upright without any anti-tipping measures next to a highly traveled forklift area.
Recent events (2)
  • — I (S) $7000
  • — Z (S) $12769

1910.253 B04 III

Serious Gravity 5 2 instances 1 exposed
Issued
Jul 30, 2025
Abate by
Aug 11, 2025
Penalty
Initial $0 · Current $0
29 CFR  1910.253(b)(4)(iii): Oxygen cylinders in storage were not separated from fuel-gas cylinders or combustible materials (especially oil or grease), a minimum distance of 20 feet (6.1 m) or by a noncombustible barrier at least 5 feet (1.5 m) high having a fire-resistance rating of at least.  a. On or about April 24, 2025, in the warehouse the employer failed to separate oxygen cylinders from propylene cylinders, thereby exposing employees to fire and explosion hazards.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.253 E03 II C 3

Serious Gravity 5 1 instance 1 exposed
Issued
Jul 30, 2025
Abate by
Aug 25, 2025
Penalty
Initial $12,769 · Current $0 Reduced
29 CFR  1910.253(e)(3)(ii)(C)(3): Flashback protection was not provided by an approved device that would prevent flame from passing into the fuel gas system:  a. On or about April 24, 2025, in the warehouse the employer failed to have a flashback arrestor installed on the oxygen and propylene cylinder, thereby exposing employees to fire and explosion hazards.
Recent events (2)
  • — I (S) $0
  • — Z (S) $12769