Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: SET CONNECTORS, INC.

Referral inspection · Safety discipline

On , OSHA opened a referral safety inspection of SET CONNECTORS, INC. in 180 LYNN GROVE ROAD, NORTHWOOD, NH 03261 (NAICS 236115). OSHA activity number 348212218.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch SET Connectors, INC. — free Get an email when a new federal OSHA severe-injury report for SET Connectors, INC. is published. One employer, no account, unsubscribe in one click.
Site address
180 LYNN GROVE ROAD
City
NORTHWOOD
State
NH
ZIP
03261
Mailing
36 HOLMAN LANE, NORWAY, ME 04268
Inspection type
Referral (C)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
236115
Employees
4
Ownership type
A

4 citations on file for this inspection.

1926.502 D15 II

Serious Gravity 10 1 instance 1 exposed
Issued
Jul 11, 2025
Abate by
Jul 17, 2025
Penalty
Initial $7,282 · Current $5,000 Reduced
29 CFR  1926.502(d)(15)(ii): Anchorages used for attachment of personal fall arrest equipment was not capable of supporting at least 5,000 pounds (22.2 kN) per employee attached, and not installed under the supervision of a qualified person.  Site- On or about April 29, 2025, an employee fell 20 feet from the roof when the anchor point to which their personal fall arrest equipment was connected to failed because it was not installed with enough of the required fastening devices.
Recent events (2)
  • — I (S) $5000
  • — Z (S) $7282

1926.502 D21

Serious Gravity 5 1 instance 1 exposed
Issued
Jul 11, 2025
Abate by
Jul 17, 2025
Penalty
Initial $0 · Current $0
29 CFR  1926.502(d)(21): Personal fall arrest systems were not inspected prior to each use for wear, damage, and other deterioration, and/or defective components were not removed from service:   Site- On or about April 29, 2025, an employee an using a damaged vertical lifeline as part of their personal fall arrest system prior to falling from the roof was not removed from service.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1926.1053 B01

Serious Gravity 5 1 instance 1 exposed
Issued
Jul 11, 2025
Abate by
Jul 17, 2025
Penalty
Initial $5,202 · Current $0 Reduced
29 CFR  1926.1053(b)(1): Where portable ladders were used for access to an upper landing surface and the ladder's length allows, the ladder side rails did not extend at least 3 feet (.9 m) above the upper landing surface being accessed:  Site- Employees using and aluminum extension ladder to access the roof were not protected from a fall hazard where the top of the ladder extended less than 3 feet from the landing surface.
Recent events (2)
  • — I (S) $0
  • — Z (S) $5202

1926.1053 B13

Serious Gravity 1 1 instance 3 exposed
Issued
Jul 11, 2025
Abate by
Jul 17, 2025
Penalty
Initial $0 · Current $0
29 CFR  1926.1053(b)(13): The top or top step of a stepladder was used as a step:   Site- Employees using a 4 foot fiberglass step ladder to access the first floor of the residence were not protected from a fall hazard where the top step of the stepladder was used for access.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

View SET Connectors, INC.'s full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 348212218.