Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: HAYASHI TELEMPU NORTH AMERICA CORPORATION

Complaint inspection · Safety discipline

On , OSHA opened a complaint safety inspection of HAYASHI TELEMPU NORTH AMERICA CORPORATION in 1500 KINGSVIEW DR., LEBANON, OH 45036 (NAICS 314110). OSHA activity number 348212838.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Hayashi Telempu North America Corporation — free Get an email when a new federal OSHA severe-injury report for Hayashi Telempu North America Corporation is published. One employer, no account, unsubscribe in one click.
Site address
1500 KINGSVIEW DR.
City
LEBANON
State
OH
ZIP
45036
Mailing
1500 KINGSVIEW DR., LEBANON, OH 45036
Inspection type
Complaint (B)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
A
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
314110
Employees
300
Ownership type
A

4 citations on file for this inspection.

1910.212 A01

Other-than-serious Gravity 10 2 instances 2 exposed
Issued
Sep 4, 2025
Abate by
Feb 2, 2026
Penalty
Initial $16,550 · Current $16,550
29 CFR  1910.212(a)(1):Types of guarding. One or more methods of machine guarding shall be provided to protect the operator and other employees in the machine area from hazards such as those created by point of operation, ingoing nip points, rotating parts, flying chips and sparks. Examples of guarding methods are-barrier guards, two-hand tripping devices, electronic safety devices, etc.  a) On or about April 30, 2025, the employer did not ensure that the Auto Mold rotating section (Work Center 14) was guarded to protect employees from pinch point and struck by hazards in that the equipment could be restarted from the control stand while employees were still inside the operational area.  b) On or about April 30, 2025, the employer did not ensure that guarding was provided at the in running nip point where the rollers meet the front of the Happi 1 and Happi 2 machines (Work Center 8), exposing employees to caught-in hazards.
Recent events (2)
  • — I (O) $16550
  • — Z (S) $16550

1910.303 G01

Other-than-serious 1 instance 7 exposed
Issued
Sep 4, 2025
Penalty
Initial $1,328 · Current $1,328
29 CFR  1910.303(g)(1): Electrical. General. Space about electric equipment. Sufficient access and working space shall be provided and maintained about all electric equipment to permit ready and safe operation and maintenance of such equipment.  a)  On or about April 30, 2025, the employer did not maintain the minimum required working space around electrical panels as required by 29 CFR 1910.303(g)(1) and Table S-1. Specifically, 480-volt, 208-volt, and 220-volt panels were obstructed by equipment, cabinets, and tool organizers, preventing safe access and exposing employees to electrical shock hazards.
Recent events (2)
  • — I (O) $1328
  • — Z (O) $1328

1910.305 G02 III

Other-than-serious 1 instance 7 exposed
Issued
Sep 4, 2025
Abate by
Oct 22, 2025
Penalty
Initial $1,328 · Current $0 Reduced
29 CFR  1910.305(g)(2)(iii): Flexible cords and cables shall be connected to devices and fittings so that strain relief is provided that will prevent pull from being directly transmitted to joints or terminal screws.  a) On or about April 30, 2025, in the Maintenance Area, electrical cords entering 480-volt electrical panels located on the right-side wall were not provided with strain relief. As a result, pull on the cords could be directly transmitted to the terminal connections, exposing employees to electrical hazards.
Recent events (2)
  • — I (O) $0
  • — Z (O) $1328

1910.305 F01

Other-than-serious 1 instance 7 exposed
Issued
Sep 4, 2025
Penalty
Initial $1,328 · Current $0 Reduced
29 CFR  1910.305(f)(1): Electrical. Conductors for general wiring. Insulation. All conductors used for general wiring shall be insulated unless otherwise permitted in this subpart.  a) On or about April 30, 2025, in the Maintenance Area, electrical conductors coming out of the 480-volt electrical panels located against the right-side wall were not properly insulated, exposing employees to electrical hazards.
Recent events (2)
  • — I (O) $0
  • — Z (O) $1328

View Hayashi Telempu North America Corporation's full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 348212838.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.