INVERNESS, IL —
OSHA Inspection: UNLIMITED CONSTRUCTION PRO PLLC
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of UNLIMITED CONSTRUCTION PRO PLLC in 624 S BALMORAL LN, INVERNESS, IL 60067 (NAICS 238160). OSHA activity number 348223231.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- UNLIMITED CONSTRUCTION PRO PLLC
- Site address
- 624 S BALMORAL LN
- City
- INVERNESS
- State
- IL
- ZIP
- 60067
- Mailing
- 1407 N OAK AVE, ROUND LAKE BEACH, IL 60073
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Last modified
- Data loaded
Establishment context
- NAICS code
- 238160
- Employees
- 17
- Ownership type
- A
Citations
8 citations on file for this inspection.
1926.100 A
- Issued
- Jul 11, 2025
- Penalty
- Initial $4,161 · Current $2,500 Reduced
General-duty citation text
29 CFR 1926.100(a):Employees working in areas where there is a possible danger of head injury from impact, or from falling or flying objects, or from electrical shock and burns, shall be protected by protective helmets. a) On May 2, 2025, Employees were not wearing protective helmets where there was a possible danger of head injury from falling objects. No abatement certification or documentation is required for this item.
Recent events (2)
- — I (S) $2500
- — Z (S) $4161
1926.102 A01
- Issued
- Jul 11, 2025
- Penalty
- Initial $4,161 · Current $0 Reduced
General-duty citation text
29 CFR 1926.102(a)(1): Employees were not provided with eye and face protection equipment when machines or operations present potential eye or face injury from physical, chemical, or radiation agents: a) On May 2, 2025, employees were exposed to eye injury while operating pneumatic roofing nail guns without eye protection during roofing work. No abatement certification or documentation is required for this item.
Recent events (2)
- — I (S) $0
- — Z (S) $4161
1926.502 D06 I
- Issued
- Jul 11, 2025
- Penalty
- Initial $5,202 · Current $3,500 Reduced
General-duty citation text
29 CFR 1926.502(d)(6)(i): A snaphook not of the locking type was engaged directly to webbing, rope or wire rope; a) On May 2, 2025, snaphooks were connected to the nylon webbing of body harnesses used for fall protection on pitched roof surfaces. No abatement certification or documentation is required for this item
Recent events (2)
- — I (S) $3500
- — Z (S) $5202
1926.502 D15
- Issued
- Jul 11, 2025
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1926.502(d)(15): Anchorage used for attachment for personal fall arrest equipment was not capable of supporting at least 5,000 pounds (22.2 kN) per employee attached nor was it designed, installed and used as follows: As part of a complete personal fall arrest system which maintains a safety factor of at least two; and under the supervision of a qualified person: a) On May 2, 2025, the employer did not ensure that the anchorage used by employees as an attachment point for personal fall arrest system was capable of supporting at least 5,000 pound per employee attached to it. No abatement certification or documentation is required for this item.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1926.502 D17
- Issued
- Jul 11, 2025
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1926.502(d)(17):The attachment point of the body belt shall be located in the center of the wearer's back. The attachment point of the body harness shall be located in the center of the wearer's back near shoulder level, or above the wearer's head. a) On May 2, 2025, the front nylon straps of body harnesses were used as attachment points for fall protection on pitched roof surfaces. No abatement certification or documentation is required for this item.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1926.1053 B01
- Issued
- Jul 11, 2025
- Penalty
- Initial $5,202 · Current $3,500 Reduced
General-duty citation text
29 CFR 1926.1053(b)(1):When portable ladders are used for access to an upper landing surface, the ladder side rails shall extend at least 3 feet (.9 m) above the upper landing surface to which the ladder is used to gain access; or, when such an extension is not possible because of the ladder's length, then the ladder shall be secured at its top to a rigid support that will not deflect, and a grasping device, such as a grabrail, shall be provided to assist employees in mounting and dismounting the ladder. In no case shall the extension be such that ladder deflection under a load would, by itself, cause the ladder to slip off its support. a) On May 2, 2025, an extension ladder used by employees to access and egress the roof did not have its side rails extended at least 3 feet above the roof eave. No abatement certification or documentation is required for this item.
Recent events (2)
- — I (S) $3500
- — Z (S) $5202
1926.1053 B22
- Issued
- Jul 11, 2025
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1926.1053(b)(22): Employees using ladders were carrying objects or loads that could cause the employee to lose balance and fall: a) On May 2, 2025, an employee was exposed to fall hazards while carrying roofing material up the extension ladder. No abatement certification or documentation is required for this item.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1926.501 B13
- Issued
- Jul 11, 2025
- Penalty
- Initial $14,564 · Current $8,500 Reduced
General-duty citation text
29 CFR 1926.501(b)(13): Each employee(s) engaged in residential construction activities 6 feet (1.8 m) or more above lower levels were not protected by guardrail systems, safety net system, or personal fall arrest system, nor were employee(s) provided with an alternative fall protection measure under another provision of paragraph 1926.501 (b): a) On May 2, 2025, employees engaged in roofing activity were not protected from fall hazards while working at an elevation of approximately 10 feet above the ground. Unlimited Construction Pro PLLC, was previously cited for a violation of this occupational safety and health standard or its equivalent standard 29 CFR 1926.501(b)(13), which was contained in OSHA inspection number 1778803, citation number 1, item number 1a and was affirmed as a final order on 12/02/2024, with respect to a workplace located at 3841 S. Bluestem Dr, Oak Creek, WI 53154. No abatement certification or documentation is required for this item.
Recent events (2)
- — I (R) $8500
- — Z (R) $14564
More inspections at Unlimited Construction PRO Pllc
View Unlimited Construction PRO Pllc's full OSHA safety record →
More inspections in this industry (NAICS 238160)
More inspections in IL
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 348223231.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.