Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: WB METALS, LLC

Complaint inspection · Safety discipline

On , OSHA opened a complaint safety inspection of WB METALS, LLC in 708F FAIRGROUND ROAD, LUCASVILLE, OH 45648 (NAICS 332999). OSHA activity number 348231572.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch WB Metals, LLC — free Get an email when a new federal OSHA severe-injury report for WB Metals, LLC is published. One employer, no account, unsubscribe in one click.
Establishment
WB METALS, LLC
Site address
708F FAIRGROUND ROAD
City
LUCASVILLE
State
OH
ZIP
45648
Mailing
PO BOX 307, BEAVER, OH 45613
Inspection type
Complaint (B)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
332999
Employees
28
Ownership type
A

4 citations on file for this inspection.

1910.178 L01 I

Other-than-serious Gravity 5 2 instances 5 exposed
Issued
Sep 23, 2025
Penalty
Initial $6,620 · Current $3,000 Reduced
29 CFR  1910.178(l)(1)(i): Powered Industrial Trucks. Operator training. Safe operation. The employer shall ensure that each powered industrial truck operator is competent to operate a powered industrial truck safely, as demonstrated by the successful completion of the training and evaluation specified in this paragraph (l).  a) On or about May 08, 2025, the employer did not ensure that each operator had successfully completed the required training program prior to operating powered industrial trucks, such as the GEHL Dynalift DL12-40 and the Mitsubishi model FG20K
Recent events (2)
  • — I (O) $3000
  • — Z (S) $6620

1910.178 Q07

Other-than-serious Gravity 5 2 instances 5 exposed
Issued
Sep 23, 2025
Abate by
Oct 27, 2025
Penalty
Initial $6,620 · Current $0 Reduced
29 CFR  1910.178(q)(7): Powered industrial trucks. Operation of the truck.  Industrial trucks shall be examined before being placed in service, and shall not be placed in service if the examination shows any condition adversely affecting the safety of the vehicle. Such examination shall be made at least daily. Where industrial trucks are used on a round-the-clock basis, they shall be examined after each shift. Defects when found shall be immediately reported and corrected.  a) On or about May 8, 2025, employer did not ensure that daily inspections conducted were adequate prior to utilizing the GEHL Dynalift (DL12-40 model 820351) and Mitsubishi Forklift (model FG20K) on a daily basis, in that the GEHL Dynalift (DL12-40 model 820351) had split tires, and that the Mitsubishi Forklift (model FG20K)  had split tires, broken lights, and a broken seat.
Recent events (2)
  • — I (O) $0
  • — Z (S) $6620

1910.178 A06

Deleted Serious Gravity 5 1 instance 5 exposed
Issued
Sep 23, 2025
Abate by
Oct 27, 2025
Penalty
Initial $6,620 · Current $0 Reduced
29 CFR  1910.178(a)(6): Powered industrial trucks. General requirements. The user shall see that all nameplates and markings are in place and are maintained in a legible condition.  a) On or about May 08, 2025, the employer did not ensure that the Mitsubishi Forklift (model FG20K) had a data plate maintained in a legible condition, in that the data on the plate had worn off and could not be read.
Recent events (2)
  • — I (S) $0
  • — Z (S) $6620

1910.254 D09 III

Deleted Serious Gravity 10 1 instance 3 exposed
Issued
Sep 23, 2025
Abate by
Oct 27, 2025
Penalty
Initial $11,585 · Current $0 Reduced
29 CFR  1910.254(d)(9)(iii): Cables with damaged insulation or exposed bare conductors shall be replaced. Joining lengths of work and electrode cables shall be done by the use of connecting means specifically intended for the purpose. The connecting means shall have insulation adequate for the service conditions.  [55 FR 13709, Apr. 11, 1990; 61 FR 9227, March 7, 1996; 70 FR 53929, Sept. 13, 2005]    a) On or about May 08, 2025, in the Welding Shop, the employer did not ensure that ground connections on the Power MIG welder were electrically adequate, in that the ground cable lead had missing insulation, exposing employees to electrical shock hazards.
Recent events (2)
  • — I (S) $0
  • — Z (S) $11585

View WB Metals, LLC's full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 348231572.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.