ROCKFORD, IL —
OSHA Inspection: ROCKFORD TOOLCRAFT, INC.
Complaint inspection · Safety discipline
At a glance
On , OSHA opened a complaint safety inspection of ROCKFORD TOOLCRAFT, INC. in 5455 S. 11TH STREET, ROCKFORD, IL 61109 (NAICS 333514). OSHA activity number 348237181.
Where did this inspection happen?
- Establishment
- ROCKFORD TOOLCRAFT, INC.
- Site address
- 5455 S. 11TH STREET
- City
- ROCKFORD
- State
- IL
- ZIP
- 61109
- Mailing
- 766 RESEARCH PARKWAY, ROCKFORD, IL 61109
What kind of inspection was it?
- Inspection type
- Complaint (B)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 333514
- Employees
- 330
- Ownership type
- A
Citations
3 citations on file for this inspection.
1910.147 C07 I A
- Issued
- Sep 25, 2025
- Abate by
- Feb 17, 2026
- Penalty
- Initial $11,823 · Current $6,750 Reduced
General-duty citation text
29 CFR 1910.147(c)(7)(i)(A):Each authorized employee shall receive training in the recognition of applicable hazardous energy sources, the type and magnitude of the energy available in the workplace, and the methods and means necessary for energy isolation and control. On or about April 23, the employer did not ensure that employees who engaged in set-up and troubleshooting activities on the Brutus 4,400 Ton Heavy Gauge Stamping Press received training in the recognition of applicable hazardous energy sources and the methods and means necessary for isolation and control. Employees were exposed to the potential for unexpected start-up, energization, and/or movement of the equipment, exposing them to struck-by and caught-between hazards from press dies and the transfer system arms. Abatement documentation is required for this item in accordance with the requirements of 29 CFR 1903.19(d).
Recent events (2)
- — I (S) $6750
- — Z (S) $11823
1910.147 D
- Issued
- Sep 25, 2025
- Abate by
- Feb 17, 2026
- Penalty
- Initial $11,823 · Current $6,750 Reduced
General-duty citation text
29 CFR 1910.147(d):Application of control. The established procedures for the application of energy control (the lockout or tagout procedures) shall cover the following elements and actions and shall be done in the following sequence: a) On or about April 23, 2025, the employer did not ensure that employees implemented energy control steps prior to performing servicing and maintenance activities on the Brutus 4,400 Ton Heavy Gauge Stamping Press. Hazardous energy was not isolated prior to employees troubleshooting and setting up the equipment, exposing them to struck-by and caught-between hazards from press dies and transfer system arms. As a result, the remaining applicable energy control elements, involving machine isolation [1910.147(d)(3)], lockout/tagout device application [1910.147(d)(4)], dissipation of residual energy [1910.147(d)(5)(i)], and verification of isolation [1910.147(d)(6)] were not implemented to protect employees from machine hazards. Abatement documentation is required for this item in accordance with the requirements of 29 CFR 1903.19(d).
Recent events (2)
- — I (S) $6750
- — Z (S) $11823
1910.147 C06 II
- Issued
- Sep 25, 2025
- Abate by
- Feb 17, 2026
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.147(c)(6)(ii): The employer shall certify that the periodic inspections have been performed. The certification shall identify the machine or equipment on which the energy control procedure was being utilized, the date of the inspection, the employees included in the inspection, and the person performing the inspection. a) On or about April 23, 2025, the employer did not conduct and properly document periodic inspections of the company's energy control procedures as required. The employer's hazardous energy control program had deficiencies including, but not limited to employees not locking out machines or equipment prior to servicing and maintenance activities. These deficiencies could have been identified and corrected if the inspections were conducted and documented as required. Abatement documentation is required for this item in accordance with the requirements of 29 CFR 1903.19(d).
Recent events (2)
- — I (O) $0
- — Z (O) $0
More inspections at Rockford Toolcraft, INC.
View Rockford Toolcraft, INC.'s full OSHA safety record →
More inspections in this industry (NAICS 333514)
More inspections in IL
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 348237181.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.