Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: WESTLAKE NATRIUM LLC

Unprogrammed Related inspection · Safety discipline

On , OSHA opened an unprogrammed Related safety inspection of WESTLAKE NATRIUM LLC in 15696 ENERGY ROAD, PROCTOR, WV 26055 (NAICS 325998). OSHA activity number 348243734.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Westlake Natrium LLC — free Get an email when a new federal OSHA severe-injury report for Westlake Natrium LLC is published. One employer, no account, unsubscribe in one click.
Site address
15696 ENERGY ROAD
City
PROCTOR
State
WV
ZIP
26055
Mailing
15696 ENERGY ROAD, PROCTOR, WV 26055
Inspection type
Unprogrammed Related (G)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
A
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
325998
Employees
70
Ownership type
A

3 citations on file for this inspection.

1910.23 B08

Serious Gravity 10 1 instance 2 exposed
Issued
Nov 4, 2025
Abate by
Nov 17, 2025
Penalty
Initial $16,550 · Current $16,550
1910.23(b)(8)  (8) Ladders are used only for the purposes for which they were designed;  a) On or about May 11, 2025, a task was undertaken whereby a worker could not reasonably maintain three points of contact on the ladder when performing the work and did not wear fall protection on accordance with plant policy.  Abatement certification and documentation required within 10 days after abatement date. The certification shall include a statement that abatement is complete, the date and method of abatement, and state that employees and their representatives were informed of this abatement.  Abatement documentation shall include documents demonstrating that abatement is complete, such as evidence of the purchase or repair of equipment, photograph or video evidence of abatement or other written records.
Recent events (2)
  • — I (S) $16550
  • — Z (S) $16550

1910.147 F01 V

Deleted Serious Gravity 10 1 instance 2 exposed
Issued
Nov 4, 2025
Abate by
Nov 17, 2025
Penalty
Initial $0 · Current $0
29 CFR  1910.147(f)(1)(v): All systems were not de-energized and energy control measures reapplied in accordance with paragraph (d) of this section to continue the servicing and/or maintenance:   a) Caustic Department, 15696 Energy Road, Proctor, WV 26055: On or about May 11, 2025, employees performed servicing such as tightening bolts on the upper manway cover of the 1A surface condenser that was under an internal pressure of approximately 58 psi, exposing employees to a potential struck by hazard.  The condenser was not depressurized and energy control measures were not reapplied before employees began tightening bolts on the upper manway cover.   Abatement certification and documentation required within 10 days after abatement date. The certification shall include a statement that abatement is complete, the date and method of abatement, and state that employees and their representatives were informed of this abatement.  Abatement documentation shall include documents demonstrating that abatement is complete, such as evidence of the purchase or repair of equipment, photograph or video evidence of abatement or other written records.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.147 F02 I

Deleted Serious Gravity 10 1 instance 2 exposed
Issued
Nov 4, 2025
Abate by
Dec 23, 2025
Penalty
Initial $0 · Current $0
29 CFR  1910.147(f)(2)(i):  When outside servicing personnel were engaged in activities in a facility, the onsite employer and the outside employer did not inform each other of their respective lockout or tagout procedures:  a) Caustic Department, 15696 Energy Road, Proctor, WV 26055: On or about May 11, 2025, contract employees performed servicing such as tightening bolts on the upper manway cover of the 1A surface condenser that was under an internal pressure of approximately 58 psi, exposing employees to a potential struck by hazard. The employer did not ensure the outside employer was informed of  the lockout procedures and hazards of performing tasks under pressurized vessels exposing employees to potentially harmful energy.   Abatement certification and documentation required within 10 days after abatement date. The certification shall include a statement that abatement is complete, the date and method of abatement, and state that employees and their representatives were informed of this abatement.  Abatement documentation shall include documents demonstrating that abatement is complete, such as evidence of the purchase or repair of equipment, photograph or video evidence of abatement or other written records.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

View Westlake Natrium LLC's full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 348243734.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.