Safety Incidents OSHA Severe Injury Reports · 2015–2025
2,004,209Inspections Most recent open 2026-07-13 Last loaded 2026-07-17

OSHA Inspection: STRATEGIC ENVIRONMENTAL RESPONSE SOLUTIONS, LLC.

Referral inspection · Safety discipline

On , OSHA opened a referral safety inspection of STRATEGIC ENVIRONMENTAL RESPONSE SOLUTIONS, LLC. in 35 HARTFORD STREET, RUMFORD, ME 04276 (NAICS 562910). OSHA activity number 348277765.

Watch Strategic Environmental Response Solutions, LLC. — free Get an email when a new federal OSHA severe-injury report for Strategic Environmental Response Solutions, LLC. is published. One employer, no account, unsubscribe in one click.
Site address
35 HARTFORD STREET
City
RUMFORD
State
ME
ZIP
04276
Mailing
113 STADIUM DRIVE, SAREPTA, LA 71071
Inspection type
Referral (C)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
562910
Employees
8
Ownership type
A

17 citations on file for this inspection.

1910.29 B01

Other-than-serious Gravity 10 1 instance 2 exposed
Issued
Penalty
Initial $11585.00 · Current $0.00 Reduced
29 CFR 1910.29(b)(1): The top edge height of the top rail was not installed 42 inches, plus or minus 3 inches, above the walking-working surface:  ND Paper, Cogen #7 Boiler, 9th Level North Access - The top edge height of the top rail was approximately 34 inches above the walking-working surface.  The fall distance was greater than 80 feet.
Recent events (2)
  • — I (O) $0
  • — Z (S) $11585

1910.29 B06

Other-than-serious Gravity 10 1 instance 2 exposed
Issued
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.29(b)(6): Guardrail systems were not smooth-surfaced to protect employees from injury, such as punctures or lacerations, and to prevent catching or snagging of clothing:  ND Paper, Cogen #7 Boiler, 9th Level North Access - Guardrail systems were not smooth-surfaced to prevent catching or snagging of clothing.
Recent events (2)
  • — I (O) $0
  • — Z (S) $0

1910.30 A03 I

Serious Gravity 10 1 instance 1 exposed
Issued
Penalty
Initial $9847.00 · Current $7385.00 Reduced
29 CFR 1910.30(a)(3)(i): The employer did not ensure that employees were trained in the nature of the fall hazards in the work area and how to recognize them:  ND Paper, Cogen #7 Boiler, 9th Level North Access - The employer did not ensure that employees were trained in the nature of the fall hazards in the work area, and how to recognize them, before exposing employees to fall hazards of approximately 87 feet.
Recent events (2)
  • — I (S) $7385.25
  • — Z (S) $9847

1910.146 G01

Serious Gravity 10 1 instance 1 exposed
Issued
Penalty
Initial $11585.00 · Current $8689.00 Reduced
29 CFR 1910.146(g)(1): The employer did not ensure that all individuals whose work was regulated under the permit required confined spaces standard acquired the understanding, knowledge, and skills necessary for the safe performance of the duties:   ND Paper, Cogen #7 Boiler, 9th Level North Access - The employer did not ensure that a permit-required confined space attendant received the necessary training to perform their job safely.
Recent events (2)
  • — I (S) $8688.75
  • — Z (S) $11585

1910.146 F02

Serious Gravity 1 1 instance 2 exposed
Issued
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.146(f)(2): The entry permit that documented compliance and authorized entry to a permit space did not identify the purpose of the entry:  ND Paper, Cogen #7 Boiler, 9th Level North Access - The purpose of the entry section on the permit required confined space entry permit was not completed.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.146 F05

Serious Gravity 1 1 instance 2 exposed
Issued
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.146(f)(5): The entry permit that documented compliance and authorized entry to a permit space did not identify the personnel by name currently serving as the attendant(s):  ND Paper, Cogen #7 Boiler, 9th Level North Access - The attendant section on the permit required confined space entry permit was not completed.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.146 F06

Serious Gravity 5 1 instance 2 exposed
Issued
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.146(f)(6): The entry permit that documented compliance and authorized entry to a permit space did not identify the entry supervisor by name or contain the initials of the entry supervisor who originally authorized the entry:  ND Paper, Cogen #7 Boiler, 9th Level North Access - The entry supervisor section on the permit required confined space entry permit was not completed.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.146 F07

Serious Gravity 5 1 instance 2 exposed
Issued
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.146(f)(7): The entry permit that documented compliance, and authorized entry to a permit space, did not identify the hazards of the permit space to be entered:  ND Paper, Cogen #7 Boiler, 9th Level North Access - The usual contents/precautions/hazards section on the permit required confined space entry permit was not completed.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.146 F10

Serious Gravity 1 1 instance 2 exposed
Issued
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.146(f)(10): The entry permit that documented compliance and authorized entry to a permit space did not identify the results of periodic tests performed, which included the name(s) or initials of the tester:  ND Paper, Cogen #7 Boiler, 9th Level North Access - The name(s) or initials of the tester section on the confined space entry permit were not completed.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.146 H03

Serious Gravity 5 1 instance 1 exposed
Issued
Penalty
Initial $7035.00 · Current $5276.00 Reduced
29 CFR 1910.146(h)(3): The employer did not ensure that an authorized entrant communicated with the attendant as necessary to enable the attendant to monitor the entrant's status and/or the need to evacuate the space if required:  ND Paper, Cogen #7 Boiler, 9th Level North Access - The employer did not ensure that the authorized entrant communicated with the attendant as often as necessary in order for the attendant to monitor the entrant's status.
Recent events (2)
  • — I (S) $5276.25
  • — Z (S) $7035

1910.146 J02

Serious Gravity 5 1 instance 2 exposed
Issued
Penalty
Initial $5627.00 · Current $4220.00 Reduced
29 CFR 1910.146(j)(2): The employer did not ensure that each entry supervisor verified, by checking that the appropriate entries had been made on the permit, that all tests specified by the permit had been conducted, and that all procedures and equipment specified by the permit were in place before endorsing the permit and allowing entry:  ND Paper, Cogen #7 Boiler, 9th Level North Access - The employer did not ensure that an entry supervisor verified the completeness of the confined space entry permit, before employees entered the space.
Recent events (2)
  • — I (S) $4220.25
  • — Z (S) $5627

1910.146 I01

Serious Gravity 10 1 instance 1 exposed
Issued
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.146(i)(1): The employer did not ensure that each attendant knew the hazards that may be faced during entry:   ND Paper, Cogen #7 Boiler, 9th Level North Access - The employer did not ensure that each attendant was aware of the hazards that may be encountered during confined space entry, before being assigned attendant duties.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.146 I05

Serious Gravity 5 1 instance 1 exposed
Issued
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.146(i)(5): The employer did not ensure that each attendant communicated with authorized entrant(s) as necessary to monitor the entrant(s) status and/or to alert entrant(s) of the need to evacuate the space as required:  ND Paper, Cogen #7 Boiler, 9th Level North Access - The employer did not ensure that the permit required confined space attendant communicated with authorized entrant(s) as necessary to monitor entrant status.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.146 K03 I

Serious Gravity 5 1 instance 2 exposed
Issued
Abate by
Penalty
Initial $5627.00 · Current $4220.00 Reduced
29 CFR 1910.146(k)(3)(i): Each authorized entrant did not use a chest or full body harness, with a retrieval line attached at the center of the entrant's back near shoulder level or at another point which the employer can establish a profile small enough for the successful removal of the entrant:    ND Paper, Cogen #7 Boiler, 9th Level North Access - Each authorized entrant in a permit-required confined space did not use a chest or full body harness with a retrieval line, while inside the space.
Recent events (2)
  • — I (S) $4220.25
  • — Z (S) $5627

1910.146 K03 II

Serious Gravity 5 1 instance 2 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.146(k)(3)(ii): An authorized entrant entered a permit space, which was more than 5 feet deep, and did not have a retrieval line attached to a mechanical device or fixed point outside the permit space in such a manner that rescue could begin as soon as the rescuer was aware a rescue was needed:  ND Paper, Cogen #7 Boiler, 9th Level North Access - An authorized entrant entered a permit-required confined space, which had a potential fall hazard of approximately 87 feet, and did not have a retrieval line attached to a mechanical device or fixed point outside the permit space.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1904.29 B03

Deleted Other-than-serious 1 instance 1 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1904.29(b)(3): Each recordable injury or illness was not entered on the OSHA 300 Log and on an incident report within seven (7) calendar days of receiving information that a recordable injury or illness had occurred:  Facility - An employee hospitalization, which occurred on May 28, 2025, was not entered on the OSHA 300 Log or on an OSHA Form 301, or equivalent, within seven (7) calendar days.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

1910.146 C02

Deleted Other-than-serious 9 instances 1 exposed
Issued
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.146(c)(2): Permit-required confined spaces were not posted with danger signs or with another equally effective means:  ND Paper, Cogen Boiler #7 - The employer did not ensure that all entrances to a confined space were posted with a confined space sign or equally effective means of notification.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 348277765.