BRASELTON, GA —
OSHA Inspection: MASHA MASONRY, LLC
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of MASHA MASONRY, LLC in 5382 WINDER HWY, BRASELTON, GA 30517 (NAICS 238140). OSHA activity number 348285198.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- MASHA MASONRY, LLC
- Site address
- 5382 WINDER HWY
- City
- BRASELTON
- State
- GA
- ZIP
- 30517
- Mailing
- 4775 OAK GROVE DRIVE, CUMMING, GA 30040
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Last modified
- Data loaded
Establishment context
- NAICS code
- 238140
- Employees
- 10
- Ownership type
- A
Citations
4 citations on file for this inspection.
1926.451 B01
- Issued
- Jun 12, 2025
- Penalty
- Initial $2,837 · Current $1,702 Reduced
General-duty citation text
29 CFR 1926.451(b)(1): Each platform on all working levels of scaffolds was not fully planked or decked between the front uprights and the guardrail supports as specified in paragraphs 1926.451(b)(1)(i)-(ii) a) New commercial construction site located at 5382 Winder Highway Braselton, GA 30517, Scaffold: On or about 06/02/2025 the employer exposed employees to fall hazards of 14-feet, 5-inches to the lower level in that the platform decking was not complete at locations including but not limited to the access/egress point.
Recent events (2)
- — I (S) $1702.2
- — Z (S) $2837
1926.451 F04
- Issued
- Jun 12, 2025
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1926.451(f)(4): Part(s) of a scaffold that were damaged or weakened, such that the scaffold's strength was less than that required by paragraph (a) of this section, were not immediately repaired, replaced, braced to meet those provisions, nor removed from service until repaired. a) New commercial construction site located at 5382 Winder Highway Braselton, GA 30517, Scaffold: On or about June 2, 2025, employees were exposed to fall hazards of up to approximately 21 feet to the lower level. The employer did not ensure that damaged scaffold components were repaired, replaced, braced, or removed from service, in that platform planks on the scaffold were significantly dry rotted and exhibited visible longitudinal cracks across most of the deck surface.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1926.451 E01
- Issued
- Jun 12, 2025
- Penalty
- Initial $2,837 · Current $1,702 Reduced
General-duty citation text
29 CFR 1926.451(e)(1): When scaffold platforms were more than 2 feet (0.6 m) above or below a point of access, portable ladders, hook-on ladders, attachable ladders, stair towers (scaffold stairways/towers), stairway-type ladders (such as ladder stands), ramps, walkways, integral prefabricated scaffold access, or direct access from other scaffold, structure, personnel hoist, or similar surface was not used. Cross braces were used as a means of access. a) New commercial construction site located at 5382 Winder Highway Braselton, GA 30517, Scaffold: On or about June 2, 2025, the employer exposed employees to fall hazards of approximately 14 feet 5 inches to the lower level. Employees were observed climbing the scaffold frame to access and exit the upper levels because the installed ladder did not extend to the second level, and no other approved means of access, such as a properly installed ladder or stair tower, was provided.
Recent events (2)
- — I (S) $1702.2
- — Z (S) $2837
1926.451 E09 IV
- Issued
- Jun 12, 2025
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1926.451(e)(9)(iv): Cross braces on tubular welded frame scaffolds were used as a means of access or egress. a) New commercial construction site located at 5382 Winder Highway Braselton, GA 30517, Scaffold: On or about June 2, 2025, the employer exposed employees to fall hazards of approximately 14 feet 5 inches to the lower level. Employees were observed using the scaffold's cross braces to climb and descend between levels, in lieu of a proper means of access or egress, such as a ladder or stair tower, in violation of safe scaffold access requirements.
Recent events (2)
- — I (S) $0
- — Z (S) $0
More inspections at Masha Masonry, LLC
View Masha Masonry, LLC's full OSHA safety record →
More inspections in this industry (NAICS 238140)
More inspections in GA
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 348285198.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.