OSHA Inspection: NORTHSTAR STEEL FABRICATING, INC.

Complaint inspection · Safety discipline

On , OSHA opened a complaint safety inspection of NORTHSTAR STEEL FABRICATING, INC. in 1176 COON STREET, RHINELANDER, WI 54501 (NAICS 336211). OSHA activity number 348315185.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Northstar Steel Fabricating, INC. — free Get an email when a new federal OSHA severe-injury report for Northstar Steel Fabricating, INC. is published. One employer, no account, unsubscribe in one click.
Site address
1176 COON STREET
City
RHINELANDER
State
WI
ZIP
54501
Mailing
753 WASHINGTON STREET, RHINELANDER, WI 54501
Inspection type
Complaint (B)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
336211
Employees
25
Ownership type
A

5 citations on file for this inspection.

1910.178 L04 III

Serious Gravity 1 1 instance 3 exposed
Issued
Aug 11, 2025
Penalty
Initial $1,809 · Current $1,084 Reduced
29 CFR  1910.178(l)(4)(iii): Refresher training and evaluation. An evaluation of each powered industrial truck operator's performance shall be conducted at least once every three years.  a) On or about and at times prior to June 17, 2025, at the establishment located at 1176 Coon Street, Rhinelander, Wisconsin; the employer did not ensure that personnel operating sit-down forklifts had been re-evaluated on their performance every three years, exposing employees to stuck-by hazards.
Recent events (2)
  • — I (S) $1084
  • — Z (S) $1809

1910.178 P01

Serious Gravity 5 1 instance 3 exposed
Issued
Aug 11, 2025
Abate by
Sep 9, 2025
Penalty
Initial $0 · Current $0
29 CFR  1910.178(p)(1): If at any time a powered industrial truck is found to be in need of repair, defective, or in any way unsafe, the truck shall be taken out of service until it has been restored to safe operating condition.   a) On or about and at times prior to June 17, 2025, at the establishment located at 1176 Coon Street, Rhinelander, Wisconsin; employees were operating a Doosan Infracoro Co., Ltd. sit down forklift (Model: G25P-3, Serial: KQ-01647) with damage, such as but not limited to, three chunks of tire missing, exposing employees to struck-by hazards.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.178 Q07

Serious Gravity 5 1 instance 3 exposed
Issued
Aug 11, 2025
Penalty
Initial $0 · Current $0
29 CFR  1910.178(q)(7): Industrial trucks shall be examined before being placed in service, and shall not be placed in service if the examination shows any condition adversely affecting the safety of the vehicle. Such examination shall be made at least daily. Where industrial trucks are used on a round-the-clock basis, they shall be examined after each shift. Defects when found shall be immediately reported and corrected.   a) On or about and at times prior to June 17, 2025, at the establishment located at  1176 Coon Street, Rhinelander, Wisconsin; the employer did not ensure forklifts were being examined before being placed in service, exposing employees to struck-by hazards.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.212 A02

Serious Gravity 5 1 instance 2 exposed
Issued
Aug 11, 2025
Penalty
Initial $2,563 · Current $1,536 Reduced
29 CFR  1910.212(a)(2): General requirements for machine guards. Guards shall be affixed to the machine where possible and secured elsewhere if for any reason attachment to the machine is not possible. The guard shall be such that it does not offer an accident hazard in itself.  a) On or about and at times prior to June 17, 2025, at the establishment located at 1176 Coon Street, Rhinelander, Wisconsin; the employer did not ensure that the Uni-Hydro PRO 56 Ton Ironworker (Model: P56-14, Serial: 1P7749X) Slug Type Angle Shear guard was secured, exposing employees to amputation hazards.
Recent events (2)
  • — I (S) $1536
  • — Z (S) $2563

1910.212 A03 II

Serious Gravity 5 2 instances 2 exposed
Issued
Aug 11, 2025
Penalty
Initial $0 · Current $0
29 CFR  1910.212(a)(3)(ii): The point of operation of machines whose operation exposes an employee to injury, shall be guarded. The guarding device shall be in conformity with any appropriate standards therefor, or, in the absence of applicable specific standards, shall be so designed and constructed as to prevent the operator from having any part of his body in the danger zone during the operating cycle.  On or about and at times prior to June 17, 2025, at the establishment located at 1176 Coon Street, Rhinelander, Wisconsin; the employer did not ensure that machines were effectively guarded in the following instances:  a) The Uni-Hydro PRO 56 Ton Ironworker (Model: P56-14, Serial: 1P7749X) Punch Table and Adjustable Jig guard was removed, exposing employees to amputation hazards.  b) The Uni-Hydro PRO 56 Ton Ironworker (Model: P56-14, Serial: 1P7749X) Notching Station was not guarded, exposing employees to amputation hazards.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

View Northstar Steel Fabricating, INC.'s full OSHA safety record →