Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: LUIS GONZALES

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of LUIS GONZALES in 779 KEMPER RD, CINCINNATI, OH 45240 (NAICS 238160). OSHA activity number 348323874.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Luis Gonzales — free Get an email when a new federal OSHA severe-injury report for Luis Gonzales is published. One employer, no account, unsubscribe in one click.
Establishment
LUIS GONZALES
Site address
779 KEMPER RD
City
CINCINNATI
State
OH
ZIP
45240
Mailing
1125 DEMPLE AVE, DAYTON, OH 45410
Inspection type
Planned (H)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Last modified
Data loaded
NAICS code
238160
Employees
3
Ownership type
A

3 citations on file for this inspection.

1926.20 B02

Serious Gravity 10 1 instance 3 exposed
Issued
Jul 1, 2025
Abate by
Aug 6, 2025
Penalty
Initial $4,965 · Current $3,000 Reduced
29 CFR  1926.20(b)(2): Such programs shall provide for frequent and regular inspections of the job sites, materials, and equipment to be made by competent persons designated by the employers.   On or about May 7, 2025, the employer failed to ensure that a competent person performed frequent and regular inspections of the jobsite, materials, and equipment. As a result, employees replacing roofing materials worked within inches of an energized 240-volt service drop that was neither de-energized nor insulated, and worked at heights of approximately 16 feet 5 inches without an adequate fall-protection system, exposing them to electric-shock and fall hazards.
Recent events (2)
  • — I (S) $3000
  • — Z (S) $4965

1926.416 A01

Serious Gravity 5 1 instance 3 exposed
Issued
Jul 1, 2025
Abate by
Aug 6, 2025
Penalty
Initial $3,547 · Current $0 Reduced
29 CFR  1926.416(a)(1): No employer shall permit an employee to work in such proximity to any part of an electric power circuit that the employee could contact the electric power circuit in the course of work, unless the employee is protected against electric shock by deenergizing the circuit and grounding it or by guarding it effectively by insulation or other means.  a.) On or about May 7, 2025,  the employer failed to ensure that employees working in proximity to a live electrical drop line extending from the street telephone pole to the residential roof were protected from electric shock by deenergizing and grounding the circuit, or by effectively guarding it through insulation or maintaining a safe working distance. As a result, employees were exposed to electric shock hazards of 240V.
Recent events (2)
  • — I (S) $0
  • — Z (S) $3547

1926.501 B13

Serious Gravity 10 1 instance 3 exposed
Issued
Jul 1, 2025
Abate by
Aug 6, 2025
Penalty
Initial $4,965 · Current $0 Reduced
29 CFR  1926.501(b)(13):"Residential construction." Each employee engaged in residential construction activities 6 feet (1.8 m) or more above lower levels shall be protected by guardrail systems, safety net system, or personal fall arrest system unless another provision in paragraph (b) of this section provides for an alternative fall protection measure. Exception: When the employer can demonstrate that it is infeasible or creates a greater hazard to use these systems, the employer shall develop and implement a fall protection plan which meets the requirements of paragraph (k) of 1926.502. Note: There is a presumption that it is feasible and will not create a greater hazard to implement at least one of the above-listed fall protection systems. Accordingly, the employer has the burden of establishing that it is appropriate to implement a fall protection plan which complies with 1926.502(k) for a particular workplace situation, in lieu of implementing any of those systems.  a.) On or about May 7, 2025, the employer failed to protect employees from fall hazards, while conducting roof work on a 4-12 pitch roof in that the employer did not ensure that employees properly utilize a fall protection system. as a result employees were exposed to a fall height hazard of 16'5".