Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: COX CONSTRUCTION OF NORTHEAST FLORIDA, INC

Unprogrammed Other inspection · Safety discipline

On , OSHA opened an unprogrammed Other safety inspection of COX CONSTRUCTION OF NORTHEAST FLORIDA, INC in 12569 BEACH BOULEVARD, JACKSONVILLE, FL 32246 (NAICS 238130). OSHA activity number 348357583.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch COX Construction of Northeast Florida, INC — free Get an email when a new federal OSHA severe-injury report for COX Construction of Northeast Florida, INC is published. One employer, no account, unsubscribe in one click.
Site address
12569 BEACH BOULEVARD
City
JACKSONVILLE
State
FL
ZIP
32246
Mailing
2281 WINDJAMMER LANE EAST, JACKSONVILLE, FL 32224
Inspection type
Unprogrammed Other (I)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Last modified
Data loaded
NAICS code
238130
Employees
6
Ownership type
A

6 citations on file for this inspection.

1926.451 B01

Serious Gravity 10 1 instance 6 exposed
Issued
Dec 10, 2025
Penalty
Initial $9,847 · Current $5,908 Reduced
29 CFR  1926.451(b)(1): Each platform on all working levels of scaffolds was not fully planked or decked between the front uprights and the guardrail supports as specified in paragraphs 1926.451(b)(1)(i)-(ii).  a. At a temporally on a commercial building, located at 12689 Beach Boulevard, in Jacksonville, FL: On or about July 8, 2025, the employer exposed subcontractor's employees to fall hazards, in that subcontracted employees were allowed to work form working levels of scaffolds that were not fully planked or decked between the front uprights and the guardrail supports as specified in paragraphs 1926.451(b)(1)(i)-(ii).
Recent events (2)
  • — I (S) $5908.2
  • — Z (S) $9847

1926.451 C02

Serious Gravity 5 1 instance 6 exposed
Issued
Dec 10, 2025
Penalty
Initial $0 · Current $0
29 CFR  1926.451(c)(2): Supported scaffold poles, legs, posts, frames,  or uprights did not bear on base plates and mud sills or other adequate firm foundation:  a. At a temporally on a commercial building, located at 12689 Beach Boulevard, in Jacksonville, FL: On or about July 8, 2025, the employer failed to ensure the scaffold legs beared down on adequate firm foundations, exposing subcontractor's employees to a 13.9 foot fall hazard.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1926.451 E01

Serious Gravity 5 1 instance 6 exposed
Issued
Dec 10, 2025
Penalty
Initial $0 · Current $0
29 CFR  1926.451(e)(1): When scaffold platforms were more than 2 feet (0.6 m) above or below a point of access, portable ladders, hook-on ladders, attachable ladders, stair towers (scaffold stairways/towers), stairway-type ladders (such as ladder stands), ramps, walkways, integral prefabricated scaffold access, or direct access from other scaffold, structure, personnel hoist, or similar surface was not used.    a. At a temporally on a commercial building, located at 12689 Beach Boulevard, in Jacksonville, FL: On or about July 8, 2025, the employer exposed subcontractor's employees to fall hazards, in that ladders, ramps, walkways, or similar equipment was not provided to subcontracted employees to access a scaffold platform that was more than 2 feet (0.6 m) above or below a point of access.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1926.451 F03

Serious Gravity 10 1 instance 6 exposed
Issued
Dec 10, 2025
Penalty
Initial $0 · Current $0
29 CFR 1926.451(f)(3): Scaffolds and scaffold components were not inspected for visible defects by a competent person before each work shift, and after any occurrence which could affect a scaffold's structural integrity:  a. At a temporally on a commercial building, located at 12689 Beach Boulevard, in Jacksonville, FL: On or about July 8, 2025, the employer exposed subcontractors' employees to struck-by and fall hazards, in that a scaffold system and scaffold components were not inspected for visible defects by a competent person, prior to employees performing work while supported by that that scaffold system.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1926.451 G04 I

Serious Gravity 10 1 instance 6 exposed
Issued
Dec 10, 2025
Penalty
Initial $0 · Current $0
29 CFR 1926.451(g)(4)(i): Guardrail systems were not installed along all open sides and ends of platforms.  a. At a temporally on a commercial building, located at 12689 Beach Boulevard, in Jacksonville, FL: On or about July 8, 2025, the employer exposed subcontractor employees to fall hazards, in that guardrail systems were not installed along all open sides and ends of platforms prior to, and while employees using the scaffold system to access the ceiling joist to performed sheathing work.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1904.41 A01 I

Other-than-serious 1 instance 29 exposed
Issued
Aug 26, 2025
Abate by
Sep 22, 2025
Penalty
Initial $709 · Current $709
29 CFR  1904.41(a)(1)(i): The establishment had 20 or more employees but fewer than 250 employees at any time during the previous calendar year, and the establishment was classified in an industry listed in appendix A to subpart E of this part, and the employer did not electronically submit information from OSHA Form 300A Summary of Work-Related Injuries and Illnesses to OSHA or OSHA's designee by the specified date:   a. Cox Construction of Northeast Florida, Inc. located at 2281 Windjammer Lane East, in Jacksonville, FL, 32224: On or about July 8, 2025, the employer failed to electronically submit information from their OSHA Form 300A, Summary of Work-Related Injuries and Illnesses or equivalent form, for calendar year 2024 on or before March 2, 2025. The establishment employed approximately 29 employees during calendar year 2024, and was classified under the North American Industrial Classification System (NAICS) as 238130 - Framing Contractors.
Recent events (1)
  • — Z (O) $709

View COX Construction of Northeast Florida, INC's full OSHA safety record →