HATFIELD, PA —
OSHA Inspection: FLUID ENERGY PROCESSING AND EQUIPMENT COMPANY
Complaint inspection · Safety discipline
At a glance
On , OSHA opened a complaint safety inspection of FLUID ENERGY PROCESSING AND EQUIPMENT COMPANY in 2629 PENN AVENUE, HATFIELD, PA 19440 (NAICS 325998). OSHA activity number 348395989.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- FLUID ENERGY PROCESSING AND EQUIPMENT COMPANY
- Site address
- 2629 PENN AVENUE
- City
- HATFIELD
- State
- PA
- ZIP
- 19440
- Mailing
- 4300 BETHLEHEM PIKE, TELFORD, PA 18969
What kind of inspection was it?
- Inspection type
- Complaint (B)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- A
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 325998
- Employees
- 40
- Ownership type
- A
Citations
2 citations on file for this inspection.
1910.140 C18
- Issued
- Jan 14, 2026
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.140(c)(18): The employer did not ensure that personal fall protection systems are inspected before initial use during each work shift for mildew, wear, damage, and other deterioration, and defective components are removed from service: a) 2629 Penn Ave. Hatfield, PA 19440 - On or about July 24, 2025 a personal fall arrest harness had defects and was not removed from service.
Recent events (1)
- — Z (O) $0
1910.147 C06 I
- Issued
- Jan 14, 2026
- Abate by
- Feb 3, 2026
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.147(c)(6)(i): The employer did not conduct a periodic inspection of the energy control procedure at least annually to ensure that the procedure and the requirement of this standard were being followed: a) 2629 Penn Ave. Hatfield, PA 19440 - On or about July 24, 2025 the employer did not conduct periodic inspections of the energy controls procedures.
Recent events (1)
- — Z (O) $0
More inspections at Fluid Energy Processing and Equipment Company
View Fluid Energy Processing and Equipment Company's full OSHA safety record →
More inspections in this industry (NAICS 325998)
More inspections in PA
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 348395989.