HATFIELD, PA —
OSHA Inspection: FLUID ENERGY PROCESSING AND EQUIPMENT COMPANY
Complaint inspection · Health discipline
At a glance
On , OSHA opened a complaint health inspection of FLUID ENERGY PROCESSING AND EQUIPMENT COMPANY in 2629 PENN AVENUE, HATFIELD, PA 19440 (NAICS 325998). OSHA activity number 348399759.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- FLUID ENERGY PROCESSING AND EQUIPMENT COMPANY
- Site address
- 2629 PENN AVENUE
- City
- HATFIELD
- State
- PA
- ZIP
- 19440
- Mailing
- 4300 BETHLEHEM PIKE, TELFORD, PA 18969
What kind of inspection was it?
- Inspection type
- Complaint (B)
- Scope
- Partial (B)
- Discipline
- Health
- Advance notice
- No
- Union status
- A
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 325998
- Employees
- 40
- Ownership type
- A
Citations
1 citation on file for this inspection.
1910.134 F02
- Issued
- Jan 16, 2026
- Abate by
- Feb 12, 2026
- Penalty
- Initial $0 · Current $0
9135
General-duty citation text
29 CFR 1910.134(f)(2): The employer did not ensure that an employee using a tight-fitting respirator was fit tested prior to initial use of the respirator, whenever a different respirator facepiece was used, and at least annually thereafter: a) Fluid Energy - On or about July 24, 2025, employees were required to wear tight fitting elastomeric respirators when performing job tasks while handling hazardous dusts such as, Jayhawk BTDA and Ancamine 2441. The employer did not perform annual respirator fit-testing in accordance with this section. Abatement certification required within 10 days after abatement date. The certification shall include a statement that abatement is complete, date, and method of abatement, and states employees and their representatives were informed of this abatement.
Recent events (1)
- — Z (O) $0
More inspections at Fluid Energy Processing and Equipment Company
View Fluid Energy Processing and Equipment Company's full OSHA safety record →