Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: STONE ATLANTA COUNTERTOPS INC

Unprogrammed Related inspection · Health discipline

On , OSHA opened an unprogrammed Related health inspection of STONE ATLANTA COUNTERTOPS INC in 130 BEASLEY ROAD, CARTERSVILLE, GA 30120 (NAICS 327991). OSHA activity number 348453622.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Stone Atlanta Countertops INC — free Get an email when a new federal OSHA severe-injury report for Stone Atlanta Countertops INC is published. One employer, no account, unsubscribe in one click.
Site address
130 BEASLEY ROAD
City
CARTERSVILLE
State
GA
ZIP
30120
Mailing
130 BEASLEY ROAD, CARTERSVILLE, GA 30120
Inspection type
Unprogrammed Related (G)
Scope
Partial (B)
Discipline
Health
Advance notice
No
Union status
B
Opened
Closing conference
Last modified
Data loaded
NAICS code
327991
Employees
6
Ownership type
A

7 citations on file for this inspection.

1910.134 E01

Serious Gravity 5 1 instance 1 exposed
Issued
Feb 19, 2026
Abate by
Mar 19, 2026
Penalty
Initial $4,256 · Current $4,256

Hazardous substances S900

29 CFR  1910.134(e)(1):The employer did not provide a medical evaluation to determine the employee's ability to use a respirator, before the employee was fit tested or required to use the respirator in the workplace:  a) Stone fabrication warehouse/production area: On or about August 20, 2025, and at times prior, the employer exposed an employee to respiratory hazards, in that a medical evaluation was not provided when the employee was required to wear a 3M 6200 Series half-face respirator to conduct housekeeping and material handling activities.
Recent events (2)
  • — C (S) $4256
  • — Z (S) $4256

1910.134 F02

Serious Gravity 5 1 instance 1 exposed
Issued
Feb 19, 2026
Abate by
Mar 19, 2026
Penalty
Initial $5,107 · Current $5,107

Hazardous substances 9000

29 CFR  1910.134(f)(2):Employee(s) using tight-fitting facepiece respirators were not fit tested prior to initial use of the respirator:  a) Stone fabrication warehouse/production area: On or about August 20, 2025, and at times prior, the employer exposed an employee to respiratory hazards, in that the employee was not provided a fit test when required to wear a 3M 6200 half-face respirator while conducting housekeeping and material handling activities.
Recent events (2)
  • — C (S) $5107
  • — Z (S) $5107

1910.1053 D03 I

Serious Gravity 10 1 instance 1 exposed
Issued
Feb 19, 2026
Abate by
Mar 19, 2026
Penalty
Initial $5,958 · Current $5,958

Hazardous substances S900

29 CFR  1910.1053(d)(3)(i):The employer did not perform initial monitoring to assess the 8-hour TWA exposure for each employee on the basis of one or more personal breathing zone air samples that reflect the exposures of employees on each shift, for each job classification, in each work area:  a) Stone fabrication warehouse/production area: On or about August 20, 2025, and at times prior, the employer exposed an employee to respirable crystalline silica hazards, in that initial personal monitoring was not conducted, while an employee was performing housekeeping and material handling activities.
Recent events (2)
  • — C (S) $5958
  • — Z (S) $5958

1910.1053 H01

Serious Gravity 10 1 instance 1 exposed
Issued
Feb 19, 2026
Abate by
Mar 19, 2026
Penalty
Initial $5,958 · Current $5,958

Hazardous substances 9000

29 CFR  1910.1053(h)(1):The employer allowed dry sweeping or dry brushing where such activity could contribute to employee exposure to respirable crystalline silica and wet sweeping, HEPA-filtered vacuuming or other methods that minimize the likelihood of exposure were feasible:  a) Stone fabrication warehouse/production area: On or about August 20, 2025, and at times prior, the employer exposed an employee to respirable crystalline silica hazards, in that the employee was permitted to conduct dry sweeping while performing housekeeping activities in the grinding and polishing area.
Recent events (2)
  • — C (S) $5958
  • — Z (S) $5958

1910.134 C

Repeat Gravity 5 1 instance 1 exposed
Issued
Feb 19, 2026
Abate by
Mar 19, 2026
Penalty
Initial $6,809 · Current $6,809

Hazardous substances S900

29 CFR  1910.134(c):The employer did not develop and implement a written respiratory protection program with required worksite-specific procedures and elements for required respirator use:  a) Stone fabrication warehouse/production area: On or about August 20, 2025, and at times prior, the employer exposed an employee to respiratory hazards, in that a written respiratory protection program was not provided, while the employee was required to wear a 3M 6200 Series half-face respirator while performing material handling and housekeeping activities.  ATL Granite Installers & Fabricators LLC with the same ownership as Stone Atlanta Countertops LLC  was cited for a violation of this occupational safety and health standard or its equivalent standard 1910.134(c), which was contained in OSHA inspection number 1772389, citation number 1, item number 1, and was affirmed as a final order on 02/25/2025, with respect to a workplace located at 130 Beasley Road SW Cartersville, GA. 30120.
Recent events (2)
  • — C (R) $6809
  • — Z (R) $6809

1910.1200 E01

Repeat Gravity 5 1 instance 1 exposed
Issued
Feb 19, 2026
Abate by
Mar 19, 2026
Penalty
Initial $6,809 · Current $6,809

Hazardous substances S900

29 CFR  1910.1200(e)(1):Employer had not developed or implemented a written hazard communication program that included the requirements outlined in 29 CFR 1910.1200(e)(1)(i) and (e)(1)(ii):  a) Stone fabrication warehouse/production area: On or about August 20, 2025, and at times prior, the employer exposed an employee to chemical hazards, in that a hazard communication program was not developed and implemented while the employee was exposed to hazardous chemicals such as but not limited to muriatic acid, silica and soda ash.   ATL Granite Installers & Fabricators LLC with the same ownership as Stone Atlanta Countertops LLC  was cited for a violation of this occupational safety and health standard or its equivalent standard 1910.1200(e)(1), which was contained in OSHA inspection number 1772389, citation number 2, item number 3, and was affirmed as a final order on 02/25/2025, with respect to a workplace located at 130 Beasley Road SW Cartersville, GA. 30120.
Recent events (2)
  • — C (R) $6809
  • — Z (R) $6809

1910.132 D02

Other-than-serious 1 instance 1 exposed
Issued
Feb 19, 2026
Abate by
Mar 19, 2026
Penalty
Initial $0 · Current $0
29 CFR  1910.132(d)(2):The employer did not verify that the required workplace hazard assessment has been performed through a written certification which included the requirements as outlined in 29 CFR 1910.132(d)(2):  a) Stone fabrication warehouse/production area: On or about August 20, 2025, and at times prior, the employer exposed an employee to chemical and struck-by hazards, in that a certified personal protective equipment hazard assessment was not provided, while the employee was performing housekeeping and material handling activities.
Recent events (2)
  • — C (O) $0
  • — Z (O) $0

View Stone Atlanta Countertops INC's full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 348453622.