ARTHUR, IL —
OSHA Inspection: WILSON'S KITCHENS & MORE, LLC
Complaint inspection · Safety discipline
At a glance
On , OSHA opened a complaint safety inspection of WILSON'S KITCHENS & MORE, LLC in 1702 COUNTY ROAD 2300 NORTH, ARTHUR, IL 61911 (NAICS 337110). OSHA activity number 348454000.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- WILSON'S KITCHENS & MORE, LLC
- Site address
- 1702 COUNTY ROAD 2300 NORTH
- City
- ARTHUR
- State
- IL
- ZIP
- 61911
- Mailing
- 1702 COUNTY ROAD 2300 NORTH, ARTHUR, IL 61911
What kind of inspection was it?
- Inspection type
- Complaint (B)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 337110
- Employees
- 20
- Ownership type
- A
Citations
14 citations on file for this inspection.
5(a)(1)
- Issued
- Jan 30, 2026
- Abate by
- Mar 3, 2026
- Penalty
- Initial $3,972 · Current $2,780 Reduced
General-duty citation text
OSH ACT of 1970 Section (5)(a)(1): The employer did not furnish employment and a place of employment which were free from recognized hazards that were causing or likely to cause death or serious physical harm to employees in that employees were exposed to fall hazards while working from a platform resting on the forks of a powered industrial truck: On or about December 2, 2025, an employee was exposed to fall hazards while working from a pallet resting on the forks of the Hyster Fortis 50 Lift Truck, Model Number H50FT, Serial Number P177V04044N, because the pallet did not indicate the maximum work load including personnel and equipment, the weight of the empty platform, or the minimum capacity of the truck on which the platform could be used in accordance with ANSI B56.1-2012, American National Standard for Safety Standard for Low Lift and High Lift Trucks, Sections 4.17.2, 4.17.3 and 7.37.
Recent events (2)
- — I (S) $2780.2
- — Z (S) $3972
1910.147 C04 II B
- Issued
- Jan 30, 2026
- Abate by
- Mar 24, 2026
- Penalty
- Initial $3,972 · Current $0 Reduced
General-duty citation text
29 CFR 1910.147(c)(4)(ii)(B): The energy control procedures did not clearly and specifically outline the steps for shutting down, isolating, blocking and securing machines or equipment to control hazardous energy: On or about December 2, 2025, an employee was exposed to injury while performing servicing and maintenance activities on the planer and other equipment because the energy control procedures did not clearly and specifically outline the steps for shutting down and isolating all energy sources.
Recent events (2)
- — I (O) $0
- — Z (S) $3972
1910.147 C04 II C
- Issued
- Jan 30, 2026
- Abate by
- Mar 24, 2026
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.147(c)(4)(ii)(C): The energy control procedure did not clearly and specifically outline the steps for placement, removal and transfer of lockout devices or tagout devices and the responsibility for them: On or about December 2, 2025, an employee was exposed to injury while performing servicing and maintenance activities on the planer and other equipment because the energy procedures did not clearly and specifically outline the steps for the placement, removal and transfer of lockout devices.
Recent events (2)
- — I (O) $0
- — Z (S) $0
1910.147 C04 II D
- Issued
- Jan 30, 2026
- Abate by
- Mar 24, 2026
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.147(c)(4)(ii)(D): The energy control procedures did not clearly and specifically outline the requirements for testing a machine or equipment to determine and verify the effectiveness of lockout devices, tagout devices, and other energy control: On or about December 2, 2025, an employee was exposed to injury while performing servicing and maintenance activities on the planer and other equipment because the energy control procedures did not clearly and specifically outline the requirements for verifying the effectiveness of the lockout devices.
Recent events (2)
- — I (O) $0
- — Z (S) $0
1910.147 C07 I A
- Issued
- Jan 30, 2026
- Abate by
- Mar 24, 2026
- Penalty
- Initial $3,972 · Current $0 Reduced
General-duty citation text
29 CFR 1910.147(c)(7)(i)(A): Authorized employee(s) did not receive training in the recognition of applicable hazardous energy sources, the type and magnitude of the energy available in the workplace, and the methods and means necessary for energy isolation and control: On or about December 2, 2025, an employee was exposed to injury while servicing and maintaining the planer and other equipment and the employer had not trained the employee in accordance with the standard.
Recent events (2)
- — I (O) $0
- — Z (S) $3972
1910.147 C06 I
- Issued
- Jan 30, 2026
- Abate by
- Mar 24, 2026
- Penalty
- Initial $3,972 · Current $0 Reduced
General-duty citation text
29 CFR 1910.147(c)(6)(i): The employer did not conduct a periodic inspection of the energy control procedure at least annually to ensure that the procedure and the requirement of this standard were being followed: On or about December 2, 2025, an employee was exposed to injury while performing servicing and maintenance activities on the planer and other equipment and the employer did not conduct a periodic inspection of the lockout procedures to ensure they were adequate, and that the energy control steps were followed prior to the start of servicing and maintenance activities.
Recent events (2)
- — I (S) $0
- — Z (S) $3972
1910.178 L04 III
- Issued
- Jan 30, 2026
- Penalty
- Initial $2,838 · Current $0 Reduced
General-duty citation text
29 CFR 1910.178(l)(4)(iii): An evaluation of each powered industrial truck operator's performance was not being conducted at least once every three years: On or about August 20, 2025, employees were exposed to injury while operating the Hyster Fortis 50 Lift Truck, Model Number H50FT, Serial Number P177V04044N, because the employer had not provided an evaluation of the operator's performance within the last three years.
Recent events (2)
- — I (O) $0
- — Z (S) $2838
1910.213 I01
- Issued
- Jan 30, 2026
- Abate by
- Mar 3, 2026
- Penalty
- Initial $1,702 · Current $1,191 Reduced
General-duty citation text
29 CFR 1910.213(i)(1): Non-working portion(s) of the blade of bandsaw(s) were not enclosed or guarded: On or about December 2, 2025, an employees was exposed to injury while operating the band saw because the guard is damaged and exposes the unused portion of the blade.
Recent events (2)
- — I (S) $1191.4
- — Z (S) $1702
1910.213 A09
- Issued
- Jan 30, 2026
- Abate by
- Mar 3, 2026
- Penalty
- Initial $2,838 · Current $0 Reduced
General-duty citation text
29 CFR 1910.213(a)(9): All belts, pulleys, gears, shafts, and moving parts were not guarded in accordance with the specific requires of 1910.219: On or about December 2, 2025, employees were exposed to injury while working at and around the planer because the chain and sprockets were not guarded.
Recent events (2)
- — I (S) $0
- — Z (S) $2838
1910.219 F03
- Issued
- Jan 30, 2026
- Abate by
- Mar 3, 2026
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.219(f)(3): Sprocket wheels and chains which were seven (7) feet or less above floors or platforms were not enclosed: On or about December 2, 2025, employees were exposed to injury while working at and around the planer because the chain and sprockets were not guarded.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.213 R04
- Issued
- Jan 30, 2026
- Abate by
- Mar 24, 2026
- Penalty
- Initial $3,972 · Current $2,780 Reduced
General-duty citation text
29 CFR 1910.213(r)(4): Suitable guard(s) were not provided to reduce to a minimum the hazard due to the point of operation: On or about August 20, 2025, employees were exposed to injury while operating the Powermatic Drill Press, Model Number 1140F, Serial Number 8914 F0725, because a suitable guard was not installed to protect employees from the point of operation. On or about December 2, 2025, an employee was exposed to injury while operating the North Tech Industrial Machinery Up Cut Saw because a suitable guard was not installed to protect employees from the point of operation.
Recent events (2)
- — I (S) $2780.4
- — Z (S) $3972
1910.178 P01
- Issued
- Jan 30, 2026
- Abate by
- Mar 3, 2026
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.178(p)(1): Powered industrial truck(s) found to be in need of repair, defective, or in any way unsafe had not been taken out of service until restored to safe operating condition: On December 2, 2025, the brake light on the Hyster Fortis 50 Lift Truck, Model Number H50FT, Serial Number P177V04044N, was not operational and the powered industrial truck was not taken out of service.
Recent events (2)
- — I (O) $0
- — Z (O) $0
1910.178 Q01
- Issued
- Jan 30, 2026
- Abate by
- Mar 3, 2026
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.178(q)(1): Any power-operated industrial truck not in safe operating condition was not taken out of service, and/or repairs were not made by authorized personnel: On December 2, 2025, the brake light on the Hyster Fortis 50 Lift Truck, Model Number H50FT, Serial Number P177V04044N, was not operational and the powered industrial truck was not taken out of service.
Recent events (2)
- — I (O) $0
- — Z (O) $0
1910.305 G02 III
- Issued
- Jan 30, 2026
- Abate by
- Mar 3, 2026
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.305(g)(2)(iii): Flexible cords and cables were not connected to devices and fittings so that strain relief was provided that would prevent pull from being directly transmitted to joints or terminal screws: On or about December 2, 2025, employees working at and around the planer were exposed to electrical hazards because there was no strain relief on the electrical cord. On or about December 2, 2025, employees working at and around the sander were exposed to electrical hazards because there was no strain relief on the electrical cord to the foot pedal.
Recent events (2)
- — I (O) $0
- — Z (O) $0
More inspections at Wilson'S Kitchens & More, LLC
View Wilson'S Kitchens & More, LLC's full OSHA safety record →
More inspections in this industry (NAICS 337110)
More inspections in IL
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 348454000.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.